Halogen Gas Test Apparatus ,VST/HDT Apparatus & Extensometer for UTM Machine - PowerPoint PPT Presentation

About This Presentation
Title:

Halogen Gas Test Apparatus ,VST/HDT Apparatus & Extensometer for UTM Machine

Description:

1)Halogen Gas Test Apparatus 1.Tube Furnace 2.Quartz Boat 3.Quartz Tube 4.Thermo couple 5.Flow meter 6.Complete set to Glassware’s 7.Electronic digital temp. Indicator K controller up to 10000c 8.Conductivity Meter 9.Ph Meter 2)VST/HDT Apparatus -VICAT SOFTENING TEMP. (ASTM D1525) :  Determination of the temperature at which a standard indenter penetrates 1mm into the surface of a plastics test specimen under one of the loads specified under uniform rate of heating.Rate of rise of temp. 50 + 50C / per hr. 120 + 120C DEFLECTION TEMPERATURE OF PLASTIC UNDER FLEXURAL LOAD ( As per ASTM D-648) Determination of temp. at which an arbitrary deformation occurs when plastics are subjected to arbitrary bending loads and conditions of continually rising temperature Rate of rise of temp. 2 + 0.20C / per min. 3)Extensometer for UTM Machine - The upper edges are adjustable in order to provide different gauge lengths for measurement. – PowerPoint PPT presentation

Number of Views:95

less

Transcript and Presenter's Notes

Title: Halogen Gas Test Apparatus ,VST/HDT Apparatus & Extensometer for UTM Machine


1
SHAMBHAVI LAB INSTRUMENTS
  • Presentation on
  • 1. Halogen Gas Test Apparatus
  • 2. VST/HDT Apparatus
  • 3. Extensometer for UTM Machine

Contact us http//www.tensiletestingmachineutm.
com
2
1.Halogen Gas Test Apparatus
  • To determine the amount of halogen acid gas
    evolved during combustion of compound based on
    halogenated polymers compounds containing
    halogenated additives, taken from cable
    insulation and outer sheath.
  • 1.Tube Furnace2.Quartz Boat3.Quartz
    Tube4.Thermo couple5.Flow meter6.Complete set
    to Glasswares7.Electronic digital temp.
    Indicator K controller up to 10000c8.Conductivity
    Meter9.Ph Meter

3
2.VST/HDT Apparatus
  • VICAT SOFTENING TEMP. (ASTM D1525)
     Determination of the temperature at which a
    standard indenter penetrates1mm into the surface
    of a plastics test specimen under one of the
    loadsspecified under uniform rate of
    heating.Rate of rise of temp. 50  50C / per hr.
    120  120C
  • DEFLECTION TEMPERATURE OF PLASTIC UNDER FLEXURAL
    LOAD ( As per ASTM D-648)Determination of temp.
    at which an arbitrary deformation occurs when
    plastics are subjected to arbitrary bending loads
    and conditions of continually rising temperature
  • Rate of rise of temp. 2  0.20C / per min.

4
3. Extensometer for UTM Machine
  • The specimen is placed in the machine between the
    grips and an extensometer if required can
    automatically record the change in gauge length
    during the test. If an extensometer is not
    fitted, the machine itself can record the
    displacement between its cross heads on which the
    specimen is held. However, this method not only
    records the change in length of the specimen but
    also all other extending / elastic components of
    the testing machine and its drive systems
    including any slipping of the specimen in the
    grips.
  • Once the machine is started it begins to apply an
    increasing load on specimen. Throughout the tests
    the control system and its associated software
    record the load and extension or compression of
    the specimen.
  •  

5
Mechanical Extensometer
We are one of the trusted names engaged in
providing a quality range of Mechanical
Extensometer to the esteemed customers. Our range
of Mechanical Extensometers is designed and
manufactured by a team of experts in order to
measure the elongation of test specimen under
load for its mechanical properties. We make sure
to check these products on certain quality
parameters before their dispatch to the clients'
end. Construction Application These products
consist two long knife edges at top, two dial
indicators and lower knife edges to actuate the
dials. The bars are pressed against the specimen
by means of clamp in such A way that the knife
edges bite the specimen to avoid slipping.
  •  


6
Mechanical Extensometer.
The upper edges are adjustable in order to
provide different gauge lengths for
measurement. As deformation takes place, the
lower knife edge transfer the movement to the
dial gauges and the deformation of specimen is
shown on the dials, so that the change in length
of specimen by 1/100 mm equals to one division of
the graduation on dial. Due to constant RD,
specifications and features are subject to change
without notice
  •  


7
Thank you !
Contact us http//www.tensiletestingmachineutm.
com
Write a Comment
User Comments (0)
About PowerShow.com