Introduction
ASENT provides a powerful LSAR Interface so that
design analysis data can be easily passed to your
Logistics group. This time-saving feature allows
a wide range of data to be passed in an automated
fashion. For example, the product tree structure,
failure rate and MTBF information, FMEA/FMECA
data, RCM Analysis results, Availability, and
Maintenance tasks can all be passed from ASENT to
the LSAR database.
4
ASENTS LSAR Interface
ASENT DB
LSAR DB
Any 1388-2B compliant LSAR tool
5
Invoking ASENTs LSAR Interface
From the Session Manager, right-click on a
project and select the LSAR interface option to
invoke the tool.
ASET DB
6
ASENTs LSAR Interface
There are Preview and Create options available
for both Exports and Imports. The preview option
takes you through a mock run and highlights any
problems. The Create option actually starts the
Export/Import.
ASET DB
7
ASENTs LSAR Interface
Here, the Export screen is displayed. The user
has complete control over what data is passed
between ASENT and EAGLE. An Initial load can
populate the LSAR database or just updates or
changes can be passed.
ASET DB
8
ASENTs LSAR Interface
When the Type of Export is set to Initial,
then all the data necessary to establish an LSAR
structure, including the XA, XB, XC, HA, and HG
tables are written out to the fullfile. If FMECA
Data is checked, then the BL record is written
out for the selected function and phase. Also,
the BA, BB, and BD tables are populated for each
node in the FMECA tree. If criticality numbers
have been calculated in ASENT and severity levels
have been defined, then the BK table is
populated. Tables BG, BH, BI, and BJ are
populated as part of the Failure Mode data export.
9
Exporting Maintainability Data
If MTTR Data is checked, then the HG table
entries for the assemblies are created. Also, for
initial exports the AA, AB, AG, and GA tables are
populated. Tables CA, CB, CC, and CD are
populated with assembly, task and subtask data,
associated with the selected Maintainability
prediction.
10
Exporting Maintainability Data
If an initial export is being performed and
Maintainability data is being exported, then the
user will see this screen. Here, the user can
choose whether or not to export task data.
ASET DB
11
Determines 4th character in the task code. HGOAEAA
Determines 5th character in the task code. HGOAEAA
The values of these settings will influence the
task code values for the C tables. In this case
the task codes would be HGOAEAA.
The 3rd character in the task code HGOAEAA
represents the 3rd character in the SMR Code. If
blank it is determined by this selection.
12
Diagnostic Report
After the user enters the cage code and any other
prompted for information, then the export runs.
This screen shows a diagnostics report for the
export. This can be saved off or printed by
clicking on the appropriate button.
ASET DB
13
Viewing the Export File
By selecting the File, View options the user can
select their export file. This screen shows a
sample export file that was created by ASENTs
LSAR interface. The A on the far left of each
line indicates an ADD, followed by the table name
(XB, XC, XH, etc)
ASET DB
14
ASENTs LSAR Interface Common Questions
Q If my failure rates have changed in ASENT or
some descriptive data was changed and I want the
changes reflected in EAGLE what do I do? A
Export the ASENT data as Change/Follow-on Data.
In EAGLE import the fullfile just like you
normally would. Q If my product tree structure
has changed in ASENT and some new assemblies or
boards have been added, how do I pass this to
EAGLE? A You would accomplish this in two
passes 1) Export the ASENT data as an initial
load and import this fullfile into EAGLE. This
will create entries for the new items and EAGLE
will kick out those that already exist. 2) Export
the ASENT data as Change/Follow-on Data. In EAGLE
import the fullfile just like you normally would
and now all of the failure rates and other data
should be updated.
15
From ASENT, export Reliability, FMECA, RCM, and
Maintainability data to EAGLE or any 1388-2B
compliant Logistics tool.
16
ASENT combines a comprehensive export feature
with its ability to import existing LSAR data, so
that design trade-offs for upgrades and redesigns
can be quickly accessed.
Data exported from ASENT to EAGLE
Product Tree Structure
Reliability Prediction Data
LSAR DB
RAMS DB
FMECA Data
RCM Analysis Results
Maintainability Data
Availability Data
17
Data Exchange
RAMS DB
LSAR DB
18
ASENT, EAGLE, and AIMSS are trademarks of
Raytheon Company. Microsoft and SQL Server are
registered trademarks of Microsoft Corporation.