Knick Analyzers and Transmitters - PowerPoint PPT Presentation

1 / 53
About This Presentation
Title:

Knick Analyzers and Transmitters

Description:

Knick Analyzers and Transmitters – PowerPoint PPT presentation

Number of Views:194
Avg rating:3.0/5.0
Slides: 54
Provided by: CK0
Category:

less

Transcript and Presenter's Notes

Title: Knick Analyzers and Transmitters


1
Knick Analyzers and Transmitters
Dr. Edgar Ballin
2
Overview about the Series
3
Stratos
  • 2402 PH
  • 2402 COND
  • 2402 CONDI
  • 2402 OXY
  • 2211 PH
  • 2211 COND
  • 2212 CONDI
  • 2211 OXY
  • 2211 X PH
  • 2211 X COND
  • 2212 X CONDI
  • 2211 X OXY

4
Stratos
Stratos Profibus
Stratos FF
  • 2221 X PH
  • 2221 X COND
  • 2222 X CONDI
  • 2221 X OXY
  • 2231 X PH
  • 2231 X COND
  • 2232 X CONDI
  • 2231 X OXY

5
Stratos
Designation
  • 2402 PH

Version 1 2
Communication 0/4 ... 20 mA 0 HART 1 Profibus
2 FF 3
Technique 4-wire 4 2-wire 2
Series Protos 3 Stratos 2
6
Stratos Main Features
  • Large, clear display
  • Optical alarm signal by red LED
  • Comprehensive service functions for monitoring
    the measuring equipment(device self-test,
    current sources, SensoCheck sensor monitoring)
  • Rugged, tightly sealed PBT enclosure
  • Easy installation with pre-assembled enclosure

7
Stratos Mounting
  • Pipe and Post MountingSet ZU0274(with or
    without protective hood ZU0276)

8
Stratos Mounting
  • Panel MountingSet ZU0275
  • Direct Mounting

9
Stratos Example for an Application
One Solution for pH-Measurement in Chemical
Sewage Water
Analyzer / Transmitter Stratos 2402 PH
Sensor
4...20 mA(Temp.)
10
Stratos Features for 2402
  • 2 signal current outputs (second for temperature
    information)
  • 2 current sources
  • AC/DC VariPower for any power supply 20...253
    Vac/dc
  • PID controller
  • 4 floating contacts, contact test function
  • 0...20 mA- and 4...20 mA-signal current
  • 2 parameter sets selectable (user defined)
  • input for Hold-signal
  • glass- and ISFET-electrode (for 2402PH only)

11
Stratos Menu Structure
12
Stratos
  • 2402 PH
  • 2402 COND
  • 2402 CONDI
  • 2402 OXY
  • 2211 PH
  • 2211 COND
  • 2212 CONDI
  • 2211 OXY
  • 2211 X PH
  • 2211 X COND
  • 2212 X CONDI
  • 2211 X OXY

13
Stratos Example for an Application
One Solution for DO - Measurement in Hazardous
Area
Variable Dissolved Oxygen (traces) in
potentially explosive area
Temperature 0 to 50 C
Communication 4 to 20 mA concentration (up to 50
ppm) HART
14
Stratos Example for an Application
One Solution for DO - Measurement in Hazardous
Area
Analyser / Transmitter Stratos 2211 X OXY
WG21A7, Option 470
Sensor 120mm / PG 13.5
Fitting ARF200 / ZU 0547
safe area
ZU0547
Power supply
4...20 mA
0 / 4...20 mA
ARF200
15
Repeater Power Supplies
WG20A2Input 4...20 mA (intrincially
safe) Output 4...20 mA Power supply 24 VDC
WG21A7Input 4...20 mA (intrincially
safe) Output 4...20 mA Power supply 230 V AC
or 24 V DC (Opt. 336) HART Opt. 470
16
Repeater Power Supplies
IsoAmp PWR A 20100F0HARTInput 4...20 mA, (3
... 22 mA, 16.5 V) Output 4...20 mA 0...20
mA 0...10 V Power supply 24 VDC
6.1 mm
17
HART Communication
Superimposed Digital Signal
Highway Addressable Remote Transducer by
HART Communication Foundation (HCF)
18
HART Communication
  • Advantages
  • widespread
  • uses 0 - 20 mA
  • existing cabels can be used
  • suited for hazardous areas
  • Disadvantages
  • not a real bus system point-to-point (maybe
    integrated within higher bus systems)
  • very slow (1.2 Kbit/s)

19
HART Communication
  • Parameterizing of a field device using a handheld
    communicator

20
Comparison between Stratos 2402 and 2211
  • 2 signal current outputs
  • 2 current sources
  • AC/DC VariPower for 20...253 Vac/dc
  • PID controller
  • 4 floating contacts, contact test function
  • 0...20 mA- and 4...20 mA-signal current
  • 2 parameter sets selectable (user defined)
  • input for Hold-signal
  • Glass- and ISFET-electrode
  • Approvals for Class I, Div. 2
  • 1 signal current loop
  • 1 current sources
  • 4 ... 20 mA-signal with 12 ... 30 V
  • -
  • -
  • 4 ... 20 mA-signal current HART
  • parameter settings also via HART
  • -
  • Glass- and ISFET-electrode
  • Approvals for Class I, Div. 1Zone 1

21
Comparison between Stratos 2402 and 2211
22
Stratos
Variable
Technique ofCommunication
ConductivityToroidal Sensors
Conductivity2-/4-pol Senors
pH-value
DO
  • 0/4...20 mA

4...20 mA HART
4...20 mA HART
23
Overview about the Series
Stratos
Process Unit 77
Protos
24
Protos 3400
25
Protos 3400
  • Protos 3400 S
  • Stainless steel
  • Polished enclosure
  • Hygienic design
  • S Applications
  • Biotechnology
  • Pharmaceutical industry
  • Food and beverage industry

26
Protos 3400
  • Protos 3400 C
  • steel enclosure
  • corrosion resistant coating
  • C Applications
  • chemical industry
  • paper industry
  • power plants
  • water and waste-water technology

27
Protos 3400
28
Protos 3400 General System Characteristics
  • multi-parameter measurement
  • pH-value, redox, ORP, dissolved oxygen
    concentration, dissolved oxygen saturation,
    conductivity, resistivity, temperature
  • sophisticated universal functionality
  • plain-text user interface with intuitive menu
    guidance
  • VariPower universal power supply 20 ... 265 V
    AC/DC
  • hazardous area application possible as 4-wire
    system with 24 V AC/DC or 85 ... 253 V AC

29
Protos 3400 General System Characteristics
stainless steel enclosure (1.4305) tightly
sealed (IP 65 and NEMA 4X)
30
Protos 3400 General System Characteristics
high-resolution, transflective graphic display
with white backlighting for best legibility under
all light conditions
31
Protos 3400 Modul Concept
modules interchangeable by user, can be
retrofitted at any time, modules available for
measurement, communication and control functions
32
Protos 3400 Modul Concept
3 module slots, any combination possible, e.g. 2
measurement plus1 communication module
33
Protos 3400 Modul Concept
modules available - pH / redox measurement -
dissolved oxygen - conductivity/resistivity -
communication (Profibus) - additional outputs -
controller functions (PID, Unical)
34
Protos 3400 Modul Concept
SMART MEDIATM card to store and transfer
parameters, software updates and measurement data
35
Protos 3400 Modul Concept
large space for fast and easy cable connection
36
Protos 3400 Special Design
hygienic design with "round corners" for best
cleanability
37
Protos 3400 Special Design
polished surface to avoid sticking particles (lt
0.8 µm roughness)
38
Protos 3400 Special Design
hygienic seal without rifts, hence no space for
germs
39
Protos 3400 Special Design
pipe/post, wall or panel mounting possible with
one housing design
40
Protos 3400 Keyboard
easy handlingsoftkeys in combination with fixed
keys for flexible and intuitive operation
41
Protos 3400 Display
detailed plain-text menus- English- Spanish-
French- ... 6 languages selectable
42
Protos 3400 Display
main parameter display of one or two values
43
Protos 3400 Display
two secondary value displays, user-selectable
44
Protos 3400 Display
pictograph quick guidance
45
Protos 3400 Menu Structure
pictograph menu selection
46
Protos 3400 Menu Structure
47
Protos 3400 Special Knick-Features
  • Special Knick-Features
  • Sensocheck and Sensoface
  • Calibration Timer
  • Logbook
  • Extended Logbook
  • FDA Extremly Extended Logbook
  • Measurement Recorder
  • KI Recorder

48
Protos 3400 Special Knick-Features
  • Sensocheck
  • online
  • Sensoface
  • while calibration

pH/ORP Conditions of Glass and Reference System
by ImpeadanceConductivityPolarization
EffectDissolved OxygenMembrane and
ElectrolyteCalibration Timer
pH/ORP slope, zero point, response
timeDissolved Oxygenslope, zero point,
response time
  • Smiley

49
Protos 3400 Special Knick-Features
Sensornet diagram
50
Protos 3400 Special Knick-Features
Calibration Recorder
51
Protos 3400 Special Knick-Features
Logbook standard 50 entries extended
unlimited
52
Protos 3400 Special Knick-Features
Measurement Recorder
53
The End
  • Thank you for your kind attention !
Write a Comment
User Comments (0)
About PowerShow.com