Hach Integrated Information Management Waste Water, Drinking Water, Industrial Applications - PowerPoint PPT Presentation

About This Presentation
Title:

Hach Integrated Information Management Waste Water, Drinking Water, Industrial Applications

Description:

Hach Integrated Information Management Waste Water, Drinking Water, Industrial Applications Price/ Performance Operations & Business Information – PowerPoint PPT presentation

Number of Views:74
Avg rating:3.0/5.0
Slides: 5
Provided by: mpr39
Category:

less

Transcript and Presenter's Notes

Title: Hach Integrated Information Management Waste Water, Drinking Water, Industrial Applications


1
Hach Integrated Information Management Waste
Water, Drinking Water, Industrial Applications
Price/ Performance
Operations Business Information
Maintenance Information
Laboratory Sample Information
Operations Control

Computerized Maintenance Management
Systems Inventory and Asset Maintenance Example
s Maximo, Hansen, Dataforum
Laboratory Information Management
Systems Designed for commercial and highly
centralized laboratories Examples ATL, Tribal
Hach Water Information Management SolutionTM
Hach WIMSTM Range of products Enterprise,
Professional, Deluxe, Standard, Single User

Supervisory Control and Data Acquisition (SCADA)
Hach LAB CalTM Sample Scheduling and Tracking
Solution Affordable, Effective, Lab Data
Management designed for sample scheduling
workflow in water utility labs requires WIMS
OnDemand SaaS
Hach JOB Cal Basic Hach JOB Cal
Plus Maintenance Scheduling and Tracking
Solution Easy to set up.. Easy to learn.. Easy
to use
Examples GE iFix (built-in interface)
Wonderware, Foxboro, Rockwell
Data from automated manual sources in a
central, secure repository providing easy
regulatory ad hoc reporting, analysis
monitoring
WIMS
CMMS
LIMS
SCADA
Hach solutions
2
Saving power by managing your aeration
  • Problem
  • Fine bubble aeration systems have saved
    wastewater treatment plants significant dollars
    in power costs. However, these systems need to
    be maintained.
  • Oxygen transfer efficiency is a function of
    bubble size. The smaller the bubble, the higher
    the efficiency.
  • Ceramic diffusers will foul in time, causing the
    bubble size to increase.
  • Membrane diffusers foul and they also age.
  • Current practices
  • Equip several diffusers (0.01) with pressure
    transducers to detect fouling.
  • Drain the basins and hand clean the diffusers.

3
Saving power by managing your aeration
Solution Electricity is used to run the blowers
to remove pounds of BOD from the waste stream.
Why not just track pounds of BOD removed per
kilowatt hour of electricity. In Hach WIMS we
define a variable that we can track. It is an
equation. Calculate the efficiency of the
aeration system to determine when to clean.
Efficiency Pounds of BOD Removed / Energy
Used
4
Saving power by managing your aeration
By trending the Efficiency over several years, a
benchmark can be established. When the
Efficiency drops below the benchmark, WIMS will
alert you. Simply plot this data over time and
it quickly becomes apparent when diffusers need
to be cleaned.