EPICS on TPS RF System - PowerPoint PPT Presentation

About This Presentation
Title:

EPICS on TPS RF System

Description:

EPICS on TPS RF System Yu-Hang Lin Radio Frequency Group NSRRC Outline History & Current Status TPS RF System TPS RF Transmitter Control Structure TPS RF Test Area ... – PowerPoint PPT presentation

Number of Views:75
Avg rating:3.0/5.0
Slides: 14
Provided by: Gra7211
Learn more at: https://epics.anl.gov
Category:
Tags: epics | tps | control | remote | system

less

Transcript and Presenter's Notes

Title: EPICS on TPS RF System


1
EPICS on TPS RF System
Yu-Hang LinRadio Frequency GroupNSRRC
2
Outline
  • History Current Status
  • TPS RF System
  • TPS RF Transmitter Control Structure
  • TPS RF Test Area Archive
  • Telephone Alarm System
  • Summary

3
History Current Status
  • Why EPICS?
  • In 2007, director of RF group says Instrument
    and control group decided to use EPICS. We also
    have to study EPICS.
  • Team member for studying EPICS in RF group
    one me.
  • Currently we use EPICS for
  • Data archive
  • Remotely system monitor
  • Telephone alarm system

4
TPS RF System
  • 300 kW transmitter by Thomson (turnkey system)
    (2 sets) THALES Klystron (2 for operation, 2
    for spare)
  • Home-made low level RF system (4 sets)
  • PETRA cavities (normal temperature) for booster
    routine operation
  • KEKB cavities (super-conducting) for storage
    ring routine operation
  • Home-made electronics control systems for
    super-conducting RF (3 sets)

5
TPS Transmitter
  • Transmitter
  • Power supply
  • Cooling system
  • Amplifiers
  • RF loads
  • Control system
  • Interlocks in control system
  • fast interlock by ICS (interlock control system)
  • slow interlock by Siemens PLC
  • All signals and status are monitored by EPICS
    IOC.

6
TPS Transmitter Control System
  • A Siemens S7-300 PLC control the startup and
    shutdown procedure of transmitter.
  • EPICS IOC (on CPCI single board computer with
    Linux operating system) communicates with PLC via
    TCP on Ethernet (PSI S7PLC driver).
  • EPICS IOC has no authority to write data to PLC
    but reading.
  • Two human-machine interface (HMI) touch panels
    are in charge of displaying and setting functions
    of PLC.
  • PLC communicates/controls ICS and PSMC via
    serial communication over Siemens protocol and
    ASCII protocol.

7
TPS Transmitter Control System
  • A Siemens S7-300 programmable logic controller
    (PLC) controls all the startup and shutdown
    procedures.
  • Two (local/remote) human-machine interfaces
    (HMI) are in charge of displaying and setting
    functions of PLC.
  • Only one either the local HMI or the remote
    HMI can perform the system operational
    functions at one time.
  • A hardware switch on the front panel switches
    the privilege of control between local and remote
    HMI.
  • EPICS interface layer communicates with PLC via
    TCP/IP for data collection only, i.e. EPICS has
    no authority to control the RF transmitter system.

8
SRF Module in RF Lab
  • Storage area before and after module assembly.
  • Coupler installation
  • Small portable clean booth
  • End group assembly
  • Component cleaning, assembly, one-month-baking,
    storage.
  • Horizontal tests
  • Cryogenic cooling power, test Dewar, bayonet
    joint.
  • RF source, radiation shielding, measurement
    instruments.
  • Pumps/gauges for cavity vacuum and insulation
    vacuum.
  • Data recording gt EPICS Channel Archiver

9
Horizontal Test at SRF Lab
SRF Module in RF Lab
10
Archive System in RF Lab
  • Too many signals need to be monitored/recorded
    during the horizontal test
  • Temperatures of cavity and cryogenic pipes
  • Flow rates of cooling water and cryogenic system
    (Nitrogen and Helium)
  • Opening scale of valves
  • Pressures of SRF module
  • Vacuum
  • DTACQ ACQ196 provides a good solution to high
    density environment. (96 channels within a single
    board)

Cornell super-conducting cavity (S0) cool down /
warm up procedure in last 3 months.
Cavity top temperature / bottom temperature
11
Archive System in RF Lab
Cornell super-conducting cavity (S0) cool down /
warm up procedure in last 3 months.
Cavity top temperature / bottom temperature
12
Telephone Alarm System
  • Data collection server collects all monitored
    data from EPICS and other data archive servers
    via UDP or TCP protocols.
  • Alarm rules are stored in the data collection
    server.
  • Control PC periodically asks data collection
    server the alarm statuses.
  • Control PC equips a dialing device (AD120) which
    connect to telephone line.
  • Once a signal satisfies its alarm conditions,
    control PC will automatically contact persons
    with speeches to distinguish which sub-system
    fail.

13
Summary
  • Currently, EPICS is not used to control any
    device on RF system. Only data collection and
    distribution are allowed.
  • Ethernet-wide broadcasting makes EPICS being a
    good tool in data recording.
  • EPICS is a main data recording tool on RF
    system in test area, especially during the TPS RF
    transmitter acceptance test and KEKB
    superconducting horizontal tests.
  • EPICS IOC on embedded Linux for digital LLRF
    will be developed after TPS RF project.
Write a Comment
User Comments (0)
About PowerShow.com