PROFINET CBA - PowerPoint PPT Presentation

1 / 21
About This Presentation
Title:

PROFINET CBA

Description:

Automation and Drives What is PROFINET? The vision: Plug&Work in the production line Plug&Work by: Pre-tested encapsulated machines CBA is based on forming ... – PowerPoint PPT presentation

Number of Views:525
Avg rating:3.0/5.0
Slides: 22
Provided by: cacheAuto
Category:
Tags: cba | profinet | profinet

less

Transcript and Presenter's Notes

Title: PROFINET CBA


1
Automation and Drives
2
What is PROFINET?
PROFINET
Process
Real-time communikation
Safety
Distributedfield devices
IT-Standards Security
PROFINET
Motion Control
Network-Installation
Distri-butedAutomation
PROFINET - the concept for the entire plant
3
PROFINET IO
PROFINET
Cyclic data exchange between PROFINET
IO-Controller and IO-Devices
SIMATIC STEP7
Industrial Ethernet
S7 317-2 PN/DPinclusive PROFINET IO
S7 41x CP 443-1 Adv
PROFIBUS DP
ET200S PN
4
PROFINET CBA
PROFINET
SIMATIC iMap
Industrial Ethernet
S7 317-2 PN/DP
S7 41x CP 443-1 Adv.
ET200S PN
5
Automation and Drives

6
The visionPlugWork in the production line
  • PlugWork by
  • Pre-tested encapsulated machines

PROFINET CBA
  • Automatic configuration of the network
  • Communication throughstandard CBA Interfaces

7
CBA is based on forming technological modules
  • Combination of

TechnologicalModule
... for implementing technological modules
8
Technological modules are representedby software
components
  • A software component is a reusable function with
    clearly defined interfaces

TechnologicalModule
Encapsulation of device functionalityin a
software component
9
Example Technological module Robot
MechanicElements
ElectricElements
User-Software
TechnologicalModule
Intelligentfield devicee.g. ET 200S-CPU
Function
e.g. Robots
10
Example Technological module Machine
Machine
TechnologicalModule
Mechanic
PLC
Function
11
Until now Programming of communication
  • Detailed know how necessary about principles and
    mechanism of the communication functions
  • Different communication calls for different bus
    systems
  • The communication relationship between the
    modules must already be known when programming

Graphical Engineering
12
Component Based Automation with iMapConnecting
instead of programming
Machine 1
START BOOL
BOOL STARTING
Machine 3
STOP BOOL
BOOL READY
START BOOL
BOOL STARTING
Cnt_IN BOOL
BOOL RUNNING
STOP BOOL
BOOL READY
I4 Cnt_OUT
Cnt_IN BOOL
BOOL RUNNING
Graphical Engineering
UI1 Lifestate
I4 Cnt_OUT
UI1 Lifestate
Machine 2
START BOOL
BOOL STARTING
STOP BOOL
BOOL READY
Cnt_IN BOOL
BOOL RUNNING
I4 Cnt_OUT
UI1 Lifestate
13
Combination of the decentralized and the central
solution under one concept
Only Components on Ethernet can be singleton
SIMATIC iMap
Industrial Ethernet
Graphical Engineering
C
PROFIBUS DP
Re-usable modules
Plant specific machineSingleton
14
Engineering concept for reusable modules
SIMATIC iMap
Industrial Ethernet
Graphical Engineering
PROFIBUS DP
Re-usable modules
15
? Creating the component
SIMATIC iMap
? Import
? Use the component and connect them
? reedit
Graphical Engineering
? Generate
SIMATIC STEP7
Station A_1
Shadow- Project
Station A_2
Station B_1
? Download /Test
PROFINET Device
16
Engineering concept for plant specific machines
SIMATIC iMap
Industrial Ethernet
C
Graphical Engineering
Plant specific machineSingleton
17
SIMATIC iMap
? Use the component and connect them
? Import
? Create the component
Graphical Engineering
? Download of the connections only
SIMATIC STEP7
SIMATIC STEP7
? Download /Test
Station A_1
Station C
  • no generating of a shadow project
  • within the component safety is possible

Shadow- Project
Station A_2
? reedit
PROFINET Device
18
SIMATIC iMap V3.0
SIMATIC iMap V3.0
SIMATICiMap V3.0
19
iMap V.3.0 Multifunction componentn functions
within an module

PLC
SW-function
CBA component V2.0 One PLC is represented by
one SW-function
PLC
SIMATIC iMap V3.0
n- SW-functions
CBA component V3.0 One PLC is represented by
several SW-function
Cost optimized by implementingseveral
technological modules in one hardware
20
Support of several PROFIBUS master systems and
local PROFINET IO-Devices
SIMATIC iMap
Consistent OPC symbolfile for the hole plant
Industrial Ethernet
CPU with severalDP master systems
S7 319-3 PN/DP(Proxy)
S7 31x-y PN/DPincluding PROFINET IO
iSlaves includingmaster interface
SIMATIC iMap V3.0
PROFIBUS DP
IntelligentET 200X
IntelligentET 200S
CPU with CBA and PROFINET IO
PROFIBUS DP
PROFIBUS DP
21
Products for Component Based Automation
Industrial Ethernet
S7 300 PN/DP
S7 400 with CP443-1 Adv
WinAC PNwith Proxy-function
Ethernet/PROFIBUSLink (Proxy)
Configuration
Configuration
PROFIBUS DP
PROFIBUS DP
DPSlaves
iSlave
I/O devices, HMI, Safety und Processdiagnosis
within a Komponenten
DP normslaves over Proxy
iSlave inclusive DP Master interface
22
The future is now!
Write a Comment
User Comments (0)
About PowerShow.com