Supports, lining and ventilation
2
Support needs
  • In soft ground tunnelling immediate support must
    be provided by a stiff lining. In such a case,
    the ground usually participates actively by
    providing resistance to outward deformation of
    the lining.
  • In medium-hard rock or in more cohesive soils,
    the ground may be strong enough to allow a
    certain open section at the tunnel face. Here,
    certain amount of stress release may permanently
    be valid before the supporting elements and the
    lining begin acting effectively. In this
    situation only a fraction of the primary ground
    pressure is acting on the lining.
  • Hard rock tunneling In hard rock the ground
    alone may preserve the stability of the opening
    so that only a thin lining, if any, will be
    necessary for surface protection.

3
Rock Quality Designation
4
Competence FactorThe term competence factor (Fc)
is defined as the ratio of the compressive
strength of the ground under uniaxial load to the
net pressure of the overburden (Muir-Wood, 1972).
He recognized the three following conditions
5
  • Geomechanics Classification (RMR System)
  • The Geomechanics Classification or the rock mass
    rating (RMR) system was developed by Bieniawski
    (1979). It utilizes the following six parameters
    all of which are measurable in the field and can
    also be obtained from borehole data.
  • a) Uniaxial compressive strength of intact rock
    material
  • b) Rock quality designation (RQD)
  • c) Spacing of discontinuities
  • d) Condition of discontinuities
  • e) Groundwater conditions
  • f) Orientation of discontinuities

6
Ă–NORM B 2203Due to the overwhelming success of
the New Austrian Tunnelling Method (NATM) there
has been a trend towards evaluation of the rock
mass quality according to the criterions of
Austrian Standard Ă–NORM B 2203. The ground is
grouped into several classes each class being
given a specific type and amount of temporary
support, in addition to specific excavation steps.
7
Example
8
  • The L2 ground condition was encountered in some
    phases of the Bolu tunnel construction, requiring
    very substantial supports in the form of a
    combination of shotcrete, rock bolts and I-beams.
  • The Austrian Tunnelling Standard Ă–NORM B 2203 is
    compiled on the qualitative base, i.e. it does
    not evaluate any parameters of rock environment
    by system of points. As a result, the rock mass
    quality evaluation depends on experience of a
    geologist and his subjective observation of rock
    mass behaviour. Though this evaluation is
    relatively simple and prompt, Ă–NORM B 2203 has
    been seen used as a business standard used to
    arrange working relations between investment
    organization and supplier of underground
    structures. The basis of rock mass quality
    evaluation according to Ă–NORM B 2203 is also the
    assessment of the financial demand of the
    technical works. Categorization of rock mass part
    into certain class of Ă–NORM B 2203 pledges the
    contractor to the relevant technological
    procedures agreed in the contract (e.g. the
    method of driving and transport of muck, as well
    as method of temporary and permanent lining).
    Each deviation from the agreed procedures
    complicates relations between investment and
    realizing (design/construct) organisations.
  • Principally the above rock classification systems
    relate to defects or potential defects of the
    rock mass and not to the inherent properties of
    the rock material. For weak rocks, the
    contribution from a rock classification system is
    more limited since behaviour of the rock will
    depend as much, or more, on the rock material
    than upon the discontinuities. Attempts to base
    support requirements for weak ground on rock
    classification figures have been notably
    unsuccessful. Generally, the evaluation of
    support needs for weak rock is more difficult
    that for strong rock.

9
Types of support
  • Steel arches
  • Steel ribs are used for reinforcement of weaker
    tunnel sections, and give rigid to semi-rigid
    support. The ribs are made from I-beam or H-beam
    structural steel bent to conform to the
    requirements of a particular tunnel
    cross-section.
  • The design of steel arches based on the notion of
    the unstable rock wedge in the crown, or possible
    asymmetrically, to be supported by the arch. The
    arch is buttressed against the rock around the
    remainder of the periphery of the tunnel, to
    limit bending stresses. The design of the
    foot-blocks is vital to the success of the system
    of support, in relation to bearing capacity of
    the ground, which may be weakened by the
    disturbance caused by the tunnel excavation. The
    weakness of steel arch support concerns the load
    at which failure may occur by lateral buckling
    and torsion.
  • Timber may be used for packing between the beams
    and the rock. However, providing continuous
    bedding against the rock may considerably
    increase the load-bearing capacity of the arches.
    A means for achieving this objective is the
    inserting between the rock and arch a bolster
    made of porous fabric filled with a weak
    sand/cement grout.

10
  • Rock bolts
  • Steel bolts are frequently set in holes drilled
    into the rock to assist in supporting the entire
    roof or individual rock slabs that tend to fall
    into a tunnel. Rock bolts maintain the stability
    of an opening by suspending the dead weight of a
    slab from the rock above by
  • providing a normal stress on the rock surface to
    clamp discontinuities together and develop beam
    action
  • by preventing key blocks becoming loosened so
    that the strength and integrity of the rock mass
    is maintained.
  • If the characteristics of the rock are such that
    the bolts will suffice in supporting the roof or
    parts thereof, the use of bolts is both safe and
    economical.
  • The effective use of bolts requires some
    understanding of the natural forces that exist
    underground. In an underground excavation all
    downward-acting forces are transmitted to the
    walls of the excavation. Most of the rock above
    the excavation is supported by natural arch
    action that bears on the walls. The arch suspends
    the remaining rock below the arch. If this
    suspended rock lacks sufficient strength, it sags
    and tension cracks develop. As the cracks work up
    into the roof, weakening the suspended strata,
    rock begins to fall all at once or over an
    extended period of time. If the rock is strong
    enough and free of large slips and cracks, the
    rock that is subject to falling usually should
    not exceed one-third of the width of the roof. It
    is this rock that bolts can support.

11
Rock Bolting
12
  • Shotcrete
  • Pneumatically applied mortar and concrete are
    increasingly being used for the support of
    underground excavations. The effectiveness of a
    shotcrete is determined by its compressive
    strength, bond strength, flexural strength and
    modulus of elasticity. A layer of shotcrete 150mm
    thick around a tunnel 10m in diameter can carry a
    load of 500 kN/m² corresponding to a burden
    exeeding 20m of rock. A combination of rock bolts
    and shotcrete has proved an excellent temporary
    support for all qualities of rock.
  • Shotcrete is best known in tunnelling as an
    integral component of the NATM method.
    Quick-setting concrete is sprayed onto the bare
    rock surface immediately after excavation, and
    rapidly hardens to form a preliminary support
    until the final lining of conventional poured
    concrete can be installed.
  • Shotcrete has advantages and disadvantages.
    Traditionally, shotcrete's quick-setting
    properties have been achieved by the injection of
    high-alkaline additives at the spraying nozzle.
    However, this method has always had its
    drawbacks. The resulting concrete is highly
    porous, and lacks strength. Caustic dust from the
    additives can cause skin and lung problems, and
    represents a health hazard to construction
    workers.
  • The German water authorities were concerned about
    the environmental problems associated with
    conventional shotcrete. Due to its porous nature,
    large quantities of groundwater seep through
    causing caustic alkalines to be leached out of
    the concrete. These are washed into aquifers and
    rivers, where they constitute a serious polluant.
    Leaching causes problems for tunnel owners as
    well, because hardened leachate rapidly blocks
    the tunnel's drainage systems.

13
  • Wire mesh
  • Wire mesh is used to support small pieces of
    loose rock or as reinforcement for shotcrete. Two
    types of wire mesh are commonly used in
    underground excavations chainlink mesh and
    weldmesh. The chainlink mesh is commonly used for
    fencing and it consists of a woven fabric of
    wire. The wire can be galvanized for corrosion
    protection and it tends to be flexible and
    strong. Weldmesh is commonly used for reinforcing
    shotcrete and it consists of a square grid of
    steel wires, welded at their intersection points.

14
  • Tunnel Lining
  • Permanent lining is required in most tunnels,
    always in soft ground and frequently in rock. The
    purpose of a lining is partly structural, to
    contain and support the ground and control inflow
    of water, as well as to provide an internal
    finishing suitable for the equipment of the
    tunnel. The principal materials and construction
    methods for permanent lining of bored tunnels
    are 1) in-situ concrete, 2) sprayed concrete
    (shotcrete), 3) segments in prefab concrete or
    cast-iron.
  • The process of placing concrete in situ was
    incompatible with timber supports. In
    consequence, the first uses of concrete were for
    tunnels in good rock and it was only with the
    introduction of steel supports that concrete
    became the norm for a tunnel lining material.
    In-situ forms used for lining tunnels are, with
    few exceptions, of the travelling type,
    constructed of steel. The travelling type form is
    constructed of steel members which are lines with
    steel plate or wood to give a surface which
    conforms with the shape of the inside surface.

15
(No Transcript)
16
  • Precast Concrete Segments
  • In recent years a number of tunnels driven
    through earth by using shields or TBMs have been
    lined with prefabricated concrete segments,
    which, in general, were placed immediately behind
    the excavating operation, either with e.g. the
    tailpiece of an excavating machine, or in the
    case of TBMs a special segment erector. The
    number of segments used to produce a ring has
    varied from two to eight or more, and the width
    of the rings has been in the range of 60 150
    cm. This method of driving a tunnel has in
    general proved very satisfactory and economical.
  • Precast concrete segments used to line large
    diameter running tunnels on the Lisbon Metro in
    Portugal were designed to withstand highly
    aggressive ground conditions. The ground water
    beneath the historic centre and below the old
    dockyards along the Tagus River is contaminated
    with chlorides, nitrates and sulphates, which are
    all aggressive to elements to steel reinforced
    concrete. Corrosion attacks to the concrete were
    a major design consideration. To comply with a
    120-year design lifespan, the concrete of the
    precast segmental linings has a permeability of
    no more than 10mm and B40 quality minimum
    strength requirement of 40 Mpa after 28 days. The
    segments also require an early strength of 10-12
    Mpa to allow a strike of the formwork within
    seven days. Meeting these specifications began
    with a low W/C ratio, which was not easily
    achieved with the SRMR (sulphate resistant
    cement) available in Portugal.

17
(No Transcript)
18
  • Ventilation of tunnels
  • Mechanical ventilation systems provide the
    temperature, humidity and air velocity conditions
    necessary to give tunnel users a reasonable
    degree of comfort during normal operation. When a
    fire occurs in a tunnel, the system must also
    provide a safe evacuation route for tunnel users
    and access for fire fighting services.
  • The choice and design of a ventilation system
    depends on these main factors
  • tunnel length, number of tubes, urban or rural
  • fresh air requirement under normal and special
    traffic situations
  • admissible air pollution around tunnel portals
  • fire safety considerations.
  • Key pollutants include carbon dioxide, nitrogen
    oxides, nitrogen dioxide, hydrocarbons PM10 and
    lead.
  • The increase in the number of long tunnels has
    created demand for better understanding of
    ventilation techniques and aerodynamics behaviour
    of vehicles. In addition to demand for design and
    operational efficiency, this is driven by the
    need to comply with new safety and environmental
    legislation.

19
  • Ventilation during construction
  • During construction it is necessary to ventilate
    a tunnel for various reasons
  • To furnish fresh air for the workers
  • To remove the dust caused by drilling, blasting,
    mucking, diesel engines, and other operations
  • To remove obnoxious gases and fumes produced by
    explosives
  • Mechanical ventilation is usually supplied by
    electric fans, as for example axial flow pressure
    fans. If air is blown into a tunnel, it may be
    forced through a lightweight pipe or fabric duct.
    If air is exhausted, it is necessary to use a
    rigid duct that will not collapse.
  • The exhaust method has the advantage of more
    quickly removing objectionable air from spaces
    occupied by the workers.