1
Monitored Drift Tube experiments
  • Preliminary results
  • Feb-Mar 2007
  • Egge van der Poel
  • Harry van der Graaf

2
Nomenclature
  • MDT measurements on three tubes
  • tube 1 aluminum
  • tube 2 messing
  • tube 3 aluminum

3
  • Fitting the obtained cosmic spectra

Landau fit f(x) performed on cosmic spectra in
gnuplot with parameters a,s,b model f(x)bexp(-
0.5((x-a)/sexp(-(x-a)/s))) the horizontal
position of the peak value (xmax) can be found by
taking the derivative of f(x) w.r.t. x and
setting this derivative to zero when doing so it
is found that xmax a spectra are to be
normalized w.r.t. time-interval and (projected)
surface of the tube -gt this gives us on
vertical scale counts/(cm2 s)
4
Example Landau fit
xmax
5
  • Fitting the obtained 55Fe spectra

Gauss fit g(x) performed on cosmic spectra in
gnuplot with parameters M,S,F model g(x)F1/Se
xp(-(x-M)2/S2) the horizontal position of the
peak value (xmax) is well known to be at xmax
M again spectra are to be normalized w.r.t.
time-interval and (projected) surface of the
tube -gt this gives us on vertical scale
counts/(cm2 s)
6
Example Gauss fit
xmax
7
Comparisons
  • Comparing difference tubes
  • Comparing effect shielding
  • Comparing effect HV

8
Comparing tubes _at_ 3200 V
9
Comparing tubes _at_ 3200 V
10
Comparing tubes _at_ 3200 V with shielding(results
from Landau fits in gnuplot)
  • tube shielding? xmax e-6
  • 1 N 1.622 0.008
  • Y 1.718 0.011
  • 2 N 1.139 0.010
  • Y 1.214 0.008
  • 3 N 1.537 0.011
  • Y 1.595 0.011

11
Conclusions comparing tubes
  • xmax position for messing tube differs from
    aluminum tubes (with and without shielding)
  • xmax(mes) lt xmax(alu)

12
  • Comparing effect shielding

13
Comparing shielding _at_ 3200 V
14
Comparing shielding _at_ 3200 V
15
Comparing shielding _at_ 3200 V
16
Conclusions comparing shielding
  • Shielding has effect on all tubes
  • Count rate reduction by 20

17
  • Comparing effect HV

18
Results Landau fit for tube 1 (shielded)
  • HV (V) xmax (e-6)
  • 3150 1.167 0.008
  • 3200 1.718 0.011
  • 3250 2.295 0.015

19
Results Landau fit for tube 2 (shielded)
  • HV (V) xmax (e-6)
  • 3150 0.848 0.007
  • 3200 1.214 0.008
  • 3250 1.602 0.016

20
Results Landau fit for tube 3 (shielded)
  • HV (V) xmax (e-6)
  • 3150 0.982 0.011
  • 3200 1.595 0.011
  • 3250 2.026 0.019

21
Results graphical
22
Conclusions effect HV
  • All tubes show (approx.) a logarithmic dependence
    of xmax on HV

23
Additions 5 March 2007
  • Tube spectra comparison with 55Fe source

24
Subtracting 'cosmics' from 'cosmics55Fe'
25
tube 1 _at_ 3200 V
26
tube 1 _at_ 3250 V
27
tube 3 _at_ 3250 V
28
Comparing different HV example tube 1
29
Gaussian fit graphical example
30
Results Gaussian fit for tube 1
  • HV (V) 55Fe xmax (e-6)
  • 3200 No 1.718 0.011
  • Yes 1.243 0.018
  • 3250 No 2.295 0.015
  • Yes 1.825 0.011

31
From xmax to gain
  • Gain G Q / (nFEe)
  • charge Q xmax / R
  • --gt G xmax / (RnFEe)
  • R 0.5 e6 Ohm
  • nFe 222
  • e 1.602 e-19 C
  • tube 1 with 55Fe
  • HV xmax Gain
  • 3200 V 1.243e-6 69901
  • 3250 V 1.825e-6 102631

32
?
  • Gain calculated with 55Fe source differs
    (x3,5)from literature (thesis Pieter Ennes)
  • -gt does the gasmixture differ from ArCO2937?

33
Conclusions
  • Distinct 55Fe peaks found when comparing spectra
    with and without 55Fe on tube
  • 55Fe peak varies with changing HV

34
(No Transcript)
35
To do still From xmax to gain for cosmicslook
into literature
  • Gain G Q / (nMIPe)
  • charge Q xmax / R
  • --gt G xmax / (RnMIPe)
  • R 0.5 e6 Ohm
  • nMIP ???
  • e 1.602 e-19 C
  • for example tube 3
  • HV xmax Gain
  • 3150 V 0.982e-6 ...
  • 3200 V 1.595e-6 ...
  • 3250 V 2.026e-6 ...