Title: Nincs diacm
1ACTIVITY OF THE DEPARTMENT OF BUILDING
ENERGETICS AND SERVICE SYSTEM IN LIGHTING
EDUCATION
RESEARCH
PRACTICE
ARTIFICIAL LIGHTING DAYLIGHTING
2EDUCATION
THERE ARE HUNGARIAN AND ENGLISH COURSES
LECTURES - BASIC ARTIFICIAL LIGHTING -
OBLIGATORY - BASIC DAYLIGHTING - ELECTIVE -
SPECIAL LIGHTING OF PUBLIC BUILDINGS -
ELECTIVE - DESIGN OF PHYSICAL ENVIRONMENT -
ELECTIVE PRACTICES - COMPLEX DESIGN
CONSULTATION - OBLIGATORY - DIPLOM WORK
CONSULTATION - OBLIGATORY
3EDUCATION
ARTIFICIAL LIGHTING
DAYLIGHTING
4PRACTICE
ARTIFICIAL LIGHTING DAYLIGHTING
- DESIGN NEW LIGHTING SYSTEM
- DESIGN
design daylighting system for new building
investigation of insolation for new building
- EXPERT WORKS
evaluation of build systems
- EXPERT WORK
advice in special problems
concerning to different problems of daylighting
5RESEARCH
ARTIFICIAL LIGHTING
Effects of dynamic lighting
DAYLIGHTING
Determination of the lighting meteorological
background
Determination of characteristics of the elements
of the openings
Method for dimensioning windows
Investigation of toplighting by a new conception
COMPLEX INVESTIGATIONS
How does the energy consumption of heating and
artificial lighting depend on relative largeness
of the window
6RESEARCH on
ARTIFICIAL LIGHTING
EFFECTS OS DYNAMIC LIGHTING
THE AIM
Answer on the following question What is the
better strategy, the permanent or the dynamic
lighting?
GENERAL INFORMATIONS
Investigations were carried out in special test
room. The task was proof-reading. Input were
permanent and different kind of dynamic
illuminance. Output were - performance, -
physiological characteristics, - subjective
opinions.
7 SUBJECTS READY TO START
8 SZÍVRITMUS REGISZTRÁLÓ ÉRZÉKELOI
9RESULTS
The dynamic lighting by adequate parameters is
better then the permanent one. Namely -
quantity of work is the same by permanent and
dynamic lighting, - quality of work is
significantly better by dynamic lighting, -
dynamic lighting keeps activation at a higher
level, - dynamic lighting is more
stimulating, - dynamic lighting is less
tiring, - dynamic lighting is more pleasant.
10RESEARCH on
DAYLIGHTING
DETERMINATION OF THE LIGHTING METEOROLOGICAL
BACKGROUND
THE AIM
Determination of the adequate lightsource for our
given geographical location. As the visual
environment is the consequence of the applied
light.
GENERAL INFORMATIONS
The bases of the determination were - global
and direct radiation, cloudiness, - luminous
efficacy of diffuse and direct natural light.
They were registered by the meteorological
station during great many years
11RESULTS
Development of a method for determination
lighting parameters from radiated
ones. Isopleth of sunlight.
12RESULTS
Isopleth of skylight.
Duration curve of skylight
13RESEARCH on
DAYLIGHTING
DETERMINATION THE CHARACTERISTICS OF THE
ELEMENTS OF OPENINGS
THE AIM
Determination of the characteristics of openings
concerning sky diffuse light.
GENERAL INFORMATIONS
Model investigation in artificial sky were
carried out to clear - the transmission factor
for diffuse skylight by different luminance
distribution, - well-effect of opening by
different skylight distribution and slope
14RESULTS
15RESULTS
16RESEARCH on
DAYLIGHTING
METHOD FOR DIMENSIONING WINDOWS
THE AIM
Develop a method for dimensioning windows, which
takes account every effects by the same weight
and explicit.
GENERAL INFORMATIONS
Several thousand model investigations were
carried out in artificial sky. The measured
values gave the bases of the new method.
RESULT
A very new explicit method, which is able to
determine the required area of windows if the
required daylight factor and architectural
characteristics of the room are known.
17RESEARCH on
DAYLIGHTING
INVESTIGATION OF TOPLIGHTING BY A NEW CONCEPTION
See later the presentation of Mr. Filetóth.
18RESEARCH on
COMPLEX INVESTIGATIONS
THE ENERGY CONSUPTION OF HEATING AND ARTIFICIAL
LIGHTING AS A FUNCTION OF THE RELATIVE LARGENESS
OF WINDOW
THE AIM
Answer the question How the relative area of
window effects on the energy consumption of
heating and artificial lighting.
GENERAL INFORMATIONS
16 characteristics of room, window, heating,
artificial lighting and working hours were taken
account during the investigation. The daylight
distribution in the room were measured in
artificial sky.
19RESULTS
20OUR ARTIFICIAL SKY