The JPARC Neutrino Target - PowerPoint PPT Presentation

About This Presentation
Title:

The JPARC Neutrino Target

Description:

The JPARC Neutrino Target – PowerPoint PPT presentation

Number of Views:45
Avg rating:3.0/5.0
Slides: 27
Provided by: naka63
Learn more at: https://www.cap.bnl.gov
Category:
Tags: jparc | neutrino | pyx | target

less

Transcript and Presenter's Notes

Title: The JPARC Neutrino Target


1
The JPARC Neutrino Target
T. Nakadaira Institute of Particle and Nuclear
Studies, High Energy Accelerator Research
Organization (KEK) for J-PARC n Beam-line
Construction Group
2
Contents
  • Introduction
  • T2K experiment, JPARC accelerator, n beam line
  • Neutrino Target
  • Conceptual design
  • Choice of the cooling method
  • Prototyping
  • Cooling test
  • Summary

3
T2K (Tokai to Kamioka) n experiment
Main Physics goals Discovery of nm? ne
Oscillation
Pure nm beam (1GeV) nm Energy spectrum
measurement
280m
4
J-PARC Facility
Hadron Beam Facility
Materials and Life Science Experimental Facility
Nuclear Transmutation
J-PARC Japan Proton Accelerator Research Complex
Joint Project between KEK and JAEA (aka JAERI)
5
J-PARC status
  • Buildings for LINAC and 3GeVPS finished.
  • North-east part of tunnel for 50GeV PS finished.
  • South-west part of tunnel will finish in FY2006.
  • First beam on 50GeV PS in FY2008

Fast ext. part
Sep. 2005
6
J-PARK n beam
  • Conventional nm beam
  • Narrow band beam Off-axis beam

Neutrino oscillation _at_ Dm23x10-3eV2
First Application (ref. BNL-E889 Proposal)
OA2?
OA0?
OA2.5?
OA3?
7
J-PARC neutrino beam line
Primary Proton beam line
Extraction point
Target
Target station
Bunch structure
Decay volume
8 (15) bunches/spill
Spill width 5ms
beam dump
muon monitor
Cycle 3.64 (3.94) sec
Near neutrino detector
Bunch spacing 600(300) ns
Bunch length 58ns (Full width)
8
Target Station
  • Accommodate
  • Baffle Graphite, 32mmf hole x 1.7m long to
    protect 1st horn
  • Target
  • 3 Horns
  • Area filled with Helium gas
  • reduce Tritium, NOx production
  • Highly radio-activated
  • 1Sv/h,
  • Need remote-controlled maintenance system
  • Need cooling (Helium vessel, radiation shield,..)

3rd horn
2nd horn
Trg 1st horn
Baffle
Target
Baffle
beam

1st Horn
2nd Horn
3rd Horn
9
Target Conceptual design
  • Core Isotropic-Graphite IG-43 (Toyo Tanso Co.
    Ltd)
  • Energy deposit Total 58kJ/spill, Max186J/g ?
    DT ? 200K. seq 7.42 MPa ?? Tensile strength
    37.2 MPa
  • Co-axial 2 layer cooling pipe Graphite /
    Ti-6Al-4V, Helium cooling

10
Irradiation Effect of Graphite
  • Expected radiation damage of the target
  • The approximation formula used by NuMI target
    group 0.25dpa/year
  • MARS simulation
    0.150.20 dpa/year
  • Dimension change shrinkage by 5mm in length in
    5 years at maximum.
    75mm in radius
  • Degradation of thermal conductivity decreased
    by 97 _at_ 200 ?C

    7080 _at_ 400 ?C
  • Magnitude of the damage strongly depends
    on
    the irradiation temperature.
  • It is better to keep the temperature of target
    around 400 800 ?C

800
1000
Irradiation Temperature(?C)
400
600
JAERI report (1991)
2dpa
-0.5
1dpa
Dimension change
Toyo-Tanso Co Ltd. IG-11
11
Target cooling Water or Helium?
Advantage
Disadvantage
12
FEM simulation of He cooling
  • Assumptions 0.19MPaHe Initial temperature 25
    ?CHe flow rate 6000 l/min ?
    194 m/secHeat convection rate 820 W/m2/K

Target Temperature
Helium Temperature
13
FEM simulation of He cooling
  • Assumptions 0.19MPa(?Possible pressure drop at
    the downstream of target is taken into account.)
  • He Initial temperature 25 ?CHe flow rate
    6000 l/min ? 194 m/secHeat convection rate
    820 W/m2/K

14
Prototype design of Target system
Optimization of the upstream part and graphite
cap is in progress.
Exhaust
Intake
Downstream Window
graphite Target
Inner Pipe t2.0mm Graphite
Outer Pipe t0.3mm Ti-6Al-4V
t0.5mm Ceramic coating (Thermal Spraying)
15
Target / Cooling pipe design
Graphite Inner pipe
Outer pipe
  • Cooling path
  • Sectional area 5.1?10-4 m2
  • Pressure drop 0.8MPa
  • cf. Inner radius of 1st horn 54mmf

Ti-6Al-4V
Inner pipe
IG-43
target
IG-43
spacer
mm
16
Mechanical Prototype of Graphite Parts
IG-43 Toyo Tanso Co. Ltd Machining by Toyo Tanso
Co. Ltd.
Cap
Inner Cooling Pipe 2mm thickness
Target Core
The manufacturability is confirmed !
17
Assembled with the acrylic-plastic outer-pipe
18
Prototypes of Ti-Alloy parts
  • Check the manufacturability
  • Made Ti-6Al-4V pipe with 0.3mm thickness by TIG
    welding
  • Pass the Helium leak test and pressure proof
    test
  • Test of the brazing between Ti-6Al-4V and
    Graphite
  • Pretreatment for Ti-alloy (Ni-plating) is
    effective.
  • We have narrowed down the blazing material

19
Helium circulation system
Sectional view of Target station
  • Helium system is placed at the machine room of
    the TS.
  • Helium compressor
  • 1st Heat exchanger (Water Jacket)
  • The outflow of heat from the exhaust helium
    (200?C) to the TS should be minimized to keep
    the alignment precision.
  • The helium pipe will be surrounded by the water
    jacket.? It work as a heat exchanger.
  • 2nd Heat exchanger

22m
Target
machine room
27m
Helium to 2nd H.Ex.
0.11MPa 100?C
1st Heat exchanger (Water Jacket)
2nd Heat exchanger
Cooling water
23m
0.16MPa 200?C
0.11MPa 25?C
Helium from target
0.23MPa 25?C
target
Compressor
20
He cooling test (1/20 scale)
  • Measure the cooling power using the heater which
    simulates the heating at the target.
  • The flow rate of Available Helium-compressor is
    1/20 of actual system
  • Small size heater and cooling pipe is used so
    that the helium flow is turbulence as well as
    actual target cooling.
  • Heating power is also 1/20.
  • Heat exchanger for this test is not commercially
    available ? We made the double-tube for the heat
    exchange using Swagelok joints.

Test of 1st Heat Ex.
21
He cooling test parameter
1/20
? Turbulence ?
22
Test setup
Cooling pipe (Inner diameter 10.5mmf)
Heater (8mmf) 1kW
Helium flow
Ceramic spacer (1mmf)
23
Heat Exchanger
3/8 inch SUS
3/4 inch SUS
90cm
Expectation Helium 200?C ?25?C _at_ 1g/s
Water 15?C ?17?C _at_ 10 l/min
This heat exchanger has the purpose of the test
of the water-jacket for the helium cooling pipe
(1st heat exchanger) in the actual system.
24
He flow _at_ test setup
  • Helium mass flow rate of 1.2g/s is
    achieved.(?1g/s is expected)
  • Measured pressure drop indicates the flow is
    turbulence.

25
He cooling test result
  • The heat exchanger works well.
  • Helium 185?C?14?C _at_ 1.2g/s
  • Water 13.7?C ?16.3?C _at_ 8.6 l/min

26
Summary
  • T2K n experiment Neutrino Oscillation search.
    2009
  • J-PARC Japan Proton Accelerator Research
    Complex
  • Linac 3GeV PS 50 GeV PS ? MLF, Hadron beam, n
    beam
  • Construction is in progress.
  • Neutrino beam line ... 1St application of
    Off-axis Narrow band beam.
  • Neutrino Target
  • Graphite Bar Co-axial 2-layer cooling pipe
    (graphite, Ti-Alloy)
  • Helium Gas Cooling
  • Several difficulties are found in the water
    cooling.
  • The cooling capability is checked by the FEM and
    the 1/20-scale test.
  • 1st Prototype of the target and cooling pipe is
    designed.
  • Mechanical prototypes of the graphite parts are
    made.
  • Welding of Ti-Alloy and the brazing between
    graphite and Ti-Alloy are tested.d
Write a Comment
User Comments (0)
About PowerShow.com