Title: Argo delayedmode salinity QC procedures
1Argo delayed-mode salinity QC procedures
Float salinity that are deemed by RT to have a
good relative vertical profile (ie. PSAL_QC
1, 2, 3) are put through the DM process. Float
salinity that are deemed bad by RT (ie. PSAL_QC
4) are not adjustable, and thus do not go
through the DM process.
Manual evaluation to detect anomalies on the
relative profile, such as spikes, that are not
detected in RT.
Adjustable float salinity.
Unadjustable float salinity.
PSAL_ADJUSTED original value PSAL_ADJUSTED_ERROR
FillValue PSAL_ADJUSTED_QC 4
Compare with statistical recommendation obtained
by accepted methods and reference database.
Difference ?S is not significant (?S lt 1x
statistical uncertainty)
Difference ?S is significant (?S gt 1x
statistical uncertainty)
2Difference ?S is significant (?S gt 1x
statistical uncertainty)
Difference ?S is not significant (?S lt 1x
statistical uncertainty)
PI evaluation
PI evaluation
Accept float salinity as good. No adjustment
needed.
Cannot accept float salinity as good.
Accept statistical recommendation.
Cannot accept statistical recommendation.
PSAL_ADJUSTED original value PSAL_ADJUSTED_ERROR
statistical uncertainty PSAL_ADJUSTED_QC 1
PSAL_ADJUSTED value recommended by statistical
analysis PSAL_ADJUSTED_ERROR statistical
uncertainty PSAL_ADJUSTED_QC 1
PI can provide alternative correction.
PI cannot provide alternative correction.
PSAL_ADJUSTED correction provided by
PI PSAL_ADJUSTED_ERROR correction uncertainty
provided by PI PSAL_ADJUSTED_QC 1
PSAL_ADJUSTED original value PSAL_ADJUSTED_ERROR
statistical uncertainty ?S
PSAL_ADJUSTED_QC 2 or 3