Title: SM6
1SM6 Range presentationProtection des transfos
MT BT
2Contents
- I. SM6 Market place
- II. Experience of a world leader
- III. Range presentation
- IV. Technological advantages
- V. Competition
- VI. Annex
3Contents
- I. SM6 Market place
- II. Experience of a world leader
- III. Range presentation
- IV. Technological advantages
- V. Competition
- VI. Annex
4SM6 Market place
MV/LV transformer substations
5SM6 Market place
Segmentation
Energy
Building
Industry
Fluair/MCset
SM61250A
SM6 1250A
SM6 1250A
SM6 630A
SM6 630A
SM6 630A
RM6
RM6
6SM6 Market place
7Contents
- I. SM6 Market place
- II. Experience of a world leader
- III. Range presentation
- IV. Technological advantages
- V. Competition
- VI. Annex
8The experience of a world leader
- To ensure unsurpassed know-how
- 30 years of SF6 use
- 45 years of expertise in factory-built cubicles
- 700 000 SM6 units in operation
- More than 1 200 000 SF6 switch units sold
- Quality service
- Widespread sales network
SM6 24
SM6 36
9Worldwide plants organized to supply at a very
short delivery time
Schneider licencies
Schneider industrial plants China Spain Italy Bel
gium Russia Vietnam Estonia Etc
10Overall quality
11Contents
- I. SM6 Market place
- II. Experience of a world leader
- III. Range presentation
- IV. Technological advantages
- V. Competition
- VI. Annex
12An adapted range for all your requirements
- Extension possibilities
- Easy installation
- Operating safe and easy
- Compact design to save space
- Soft maintenance
- Factory built assemblies
- Protection and control monitoring functions
13Compartmented factory built cubicles
1. Switch 2. Busbars 3. Operating mechanism 4.
Low voltage 5. Connection
14Compartmented factory built cubicles
1. Busbars 2. Switch 3. Operating mechanism 4.
Low voltage 5. Connection 6. Fuse
15Compartmented factory built cubicles
- SF6 circuit breaker cubicles
1. Switch 2. Busbars 3. Operating mechanism 4.
Low voltage 5. Connection and switchgear
16Compartmented factory built cubicles
- Vacuum circuit breaker cubicles
1. Switch 2. Busbars 3. Operating mechanism 4.
Low voltage 5. Connection and switchgear
17Compartmented factory built cubicles
1. Switch and contactor 2. Busbars 3. Operating
mechanism 4. Low voltage 5. Connection and
switchgear
18SM6 Product view
- Safe and easy operation total confidence
- 3 positions switch and natural interlock
- Clear symbols and animated mimic panel
- Anti - reflex lever
- Earthing switch with making capacity
- Compartmented cubicle
- Internal arc withstand (Safety membrane on the
core )
191250 A range ...
- To be present on MV / MV subtransmission market
in the countries where the metalclad concept is
not really specify in primary activity - Same size as 630 A cubicle
- Developing the same functions with fix and
withdrawable offers - Range is limited to a disconnector and circuit
breaker cubicle
2036 kV range ...
- To break into the Turkish market and to satisfy
other countries through France - Same function as 24 kV range limited at CB fixed
- To move from traditional solution in the air to a
prefabricated Offer - Homogeneous range with 24 kV SM6 range
21Integrated protection chain
- DM1-S SF1 circuit breaker
- DMV-S Evolis circuit breaker
- DM1-A SFset circuit breaker
- Reliable protection chain
- Without low voltage supply
22Internal Arc withstand
- 2 performances
- Regular 12,5kA.1s
- Range 16kA.1s
Range 16 kA.1s Bottom gas release
Range 16 kA.1s Roof gas release
23DMV A, D S vacuum CB cubicle ...
- SM6 with CB vacuum an optimised Offer
- Strong points
- Pre-engineered Offer including LV
- Reduced size
- Earthing switch with full making capacity load
break switch - Increase in endurance performance
Width 625 mm instead of 750 mm
Fixed circuit breaker
Access to cables compartment
24Contents
- I. SM6 Market place
- II. Experience of a world leader
- III. Range presentation
- IV. Technological advantages
- V. Competition
- VI. Annex
25Technological advantages Load break switch
- Switchgear (switch and disconnector) compartment
- Very low pressure (0,4 bar relative)
- Sealed pressure system
- safety membrane
- Switch - disconnector
- Earthing switch
26Technological advantages Load break switch
- 3 positions switch
- Making capacity of earthing switch
- Optimised breaking technology
Earthed
Open
Closed
27Technological advantagesPositive break
- Position indicator on operating shaft
- Direct and reliable transmission mechanism
- Natural interlocking
Closed
Open
Earthed
28Technological advantagesBusbar compartment
- Connection in horizontal plane
- Field distributors
- Insulated busbars
- No risk of error
29Technological advantages Connection and
switchgear compartment
- All types of cables
- up to 240 mm² - 630 A
- up to 630 mm² - 1250
- Single - handed connection
- Field distributors
- Fluarc SF1, Sfset, Evolis circuit breakers
30SF1 circuit breaker 630 or 1250 A
Technological advantageswide CB range
- Combined with an electronic relay and standard
sensors - Auxiliary power supply
31Technological advantages wide CB range
SFset enhanced circuit breaker - 630 A
- Special sensors
- Dedicated electronic relays
- No auxiliary power supply
32Technological advantages wide CB range
Vaccum type circuit breaker Evolis switchgear
- Combined with an electronic relay and standard
sensors - Auxiliary power supply
33Low voltage 3 offers
Technological advantages
Cabinet H 2m05
Compartment H 1m69
Cover H 1m60
34VIP relay
Technological advantages
- Used without auxiliary supply
- Transformer protection
- VIP 35 overcurrent protections and earth fault
- Network protection
- VIP 300 overcurrent protections and earth fault
35Sepam range protection , control monitoring
Sepam range protection , control and monitoring
36Sepam range performances
- Effective protection
- To meet your exact requirements( common up to
advanced applications ) - Accurate measurements detailed diagnosis
- Measuring all necessary network monitoring
- Network , machine and apparatus diagnosis
- Integral equipment control
- Pre-defined control functions , suited to all
types of switcher - Remote operation
- Open and Modbus protocoi
- Comprehensive operator data measurements, events
logging, etc...
37Factory built cubicles
Technological advantages
- For protection and control / monitoring systems
- Accessible with cables and busbars energised
38Contents
- I. SM6 Market place
- II. Experience of a world leader
- III. Range presentation
- IV. Technological advantages
- V. Competition
- VI. Annex
39Design cubicle
Competition
- 2 modular families
- Totally insulated--gt RM6
- Air Insulated System (AIS)--gtSM6
- 2 earthing switch families
- In the SF6--gt SM6 RM6
- In the air
- 2 CB families
- With SF6--gt RM6 SM6
- With vacuum --gtSM6
40Competition
Mains advantages
- 3 positions switch in front of conventional
family - Withdrawable CBs cubicle
- SF6 or Vacuum CBs unit
- Easy to manufacture for Panel Builders
- Features
- 24 kV - 20 kA - 630 A and 12 kV - 25 kA - 630 A
- 24 kV - 20 kA - 1250 A and 12 kV - 25 kA - 1250 A
- Comprehensive range with easy adaptation
- Local adaptation
41Contents
- I. SM6 Market place
- II. Experience of a world leader
- III. Range presentation
- IV. Technological advantages
- V. Competition
- V. Annex
42Connection to networks
Annex
- Incoming or outgoing unit
- Outgoing unit, right or left with or whithout
earthing switch
IM
IMC
IMB
43Protection by fuse - switch combination
Annex
- Fuses - switch combination unit
PM
QM
44Annex
Protection by fuse - switch combination
- Fuses - switch combination unit
- Fuses - switch combination unit, right or left
outgoing line
QMB
QMC
45Fuses selection
Annex
46Annex
Protection by contactor
CRM
CRM
47Annex
Protection by circuit breaker
- Single - isolation circuit breaker unit
- Single - isolation circuit breaker unit right or
left outgoing line
DM1-D or DMV-D (right only)
DM1-A or DMV-A
48Annex
Protection by circuit breaker
- Single-isolation circuit breaker unit with
autonomous protection
- Single - isolation circuit breaker unit right or
left outgoing line
DM2
DM1-S or DMV-S
49Annex
Protection by circuit breaker
- Withdrawable single - isolation circuit breaker
unit cable outgoing
- Withdrawable single - isolation circuit breaker
unit right or left outgoing line
DM1 - W
DM1 - Z
50Annex
Protection MV metering
- Voltage transformers for mains with earthed
neutral system
- Voltage transformers for mains with insulated
neutral system
CM (375 mm)
CM2 (500 mm)
51Annex
Protection MV metering
- Current and / or voltage measurement unit, right
or left outgoing line
- Current and / or voltage measurement unit
GBC - A
GBC - B
52Functions required by private networks
Annex
- Connection unit right / left outgoing line
GBM
GIM
GEM
53Annex
Functions required by private networks
- Incoming cable - connection unit
- Incoming cable - connection unit (with SF6
earthing switch)
GAM
GAM 2
54Annex
Functions required by private networks
- MV / LV transformer unit for auxiliaries
- Earthing busbars compartment
SM
TM
EMB
55Annex
Functions required by private networks
- Busbars power supply for main incoming line on
right or left and cables for standby line
NSM busbars
NSM cables
56Optimum performance
Annex
57General characteristics
Annex
58Annex
Endurance
59Operating mechanisms
Annex
60Easy installation
Annex
- Simplified civil works
- Symetric cable connection
- Identical cubicles heights and floor - level
depths