Septum Magnet Status Report - PowerPoint PPT Presentation

About This Presentation
Title:

Septum Magnet Status Report

Description:

Cooling of the right septum was not as good as expected ... Upon disassembly debris was found in the cooling circuit of the right septum. ... – PowerPoint PPT presentation

Number of Views:57
Avg rating:3.0/5.0
Slides: 8
Provided by: johnjl
Category:
Tags: magnet | report | septum | status

less

Transcript and Presenter's Notes

Title: Septum Magnet Status Report


1
Septum Magnet Status Report
  • John J. LeRose

2
(No Transcript)
3
But Seriously
  • The magnets have been used successfully for
  • GDH
  • Hypernuclear Spectroscopy
  • HAPPEX

And pentaquark
  • Problems
  • Cooling of the right septum was not as good as
    expected
  • HAPPEX limited to lt 40 µ-amps (with LH2 target)

Upon disassembly debris was found in the cooling
circuit of the right septum. Explains the
apparent malfunction of the suspicious check
valve.
4
Studies indicate that excessive coil heating
results from Møller electrons. (Eugene Chudakov)
5
Without sweeper
With sweeper
6
Training History
370 Amps ? 4.0 GeV/c at 6 ? 2.9 GeV/c at 9
7
(No Transcript)