Title: CellBind Screen
1 CellBind Screen
Micro-column affinity system
New generation Column technology
2Methods for antibody detection
Tube test Albumin (BSA) IAT LISS
IAT PEG IAT Column test BioVue ID-sys
tem These tests are based on a visible reaction
caused by agglutination of red cells after adding
anti-human globulin serum
3 Polyspecific Coombs Reagent
Contains Function 1. Anti-IgG detection of
IgG antibodies (37ºC) 2. Anti-C3d detection
of complement dependent IgG or
incomplete IgM antibodies Anti-IgM is not
necessary direct agglutination without AHG
possible in tube- and column agglutination
techniques
4Advantages of Column technology
- No separate washing steps to be performed
- Easy interpretation of the reactions
- Reactions are stable for a long period
- Possibility of automation
5New technologies
Solid-phase MTP Solidscreen Capture-R Column
affinity CellBind Screen
6CellBind columns
- Incubation compartment (LISS medium)
- Density medium
- Affinity matrix
7Affinity matrix
8Components of the gel-matrixGel coated with
- Protein G binds IgG antibodies
- Anti-C3d binds complement dependent IgG
antibodies - Anti-IgM binds IgM (reactive at 37ºC)
9Binding of sensitized red blood cells to the gel
matrix ? no agglutination of cells
10 Gel particle red cell visible
using a microscope
Red cell
Gelparticle
11Microscopic pictures of samples from Cellbind and
Column Agglutination cards
12Test procedure
40-50 ?L test cells 40-50 ?L patient plasma
or serum (or 20 ?L reagent) Incubate 15
minutes (37C) in the (CellBind) incubator
Centrifuge for 10 minutes in the CellBind
centrifuge (programmed protocol, 3 phases)
Read the reactions
13Test procedure
14Centrifugation steps
- 1. 2 min. 75 x g cells are separated from the
serum in the incubation compartment - 2. 1 min. 200 x g cells are spun down on the
top of the gel matrix, where the sensitized cells
bind to the active gel matrix - 3. 7 min.1790 x g cells that are not
sensitized are spun down through the gel to the
bottom
15Reaction strength, interpretation
4 reaction All sensitized cells will adhere on
the top of the gel matrix 3, 2, 1 and
() Cells at the top and at the bottom -
reaction Non-sensitized cells will form a
discrete button at the bottom
16Application of CellBind
Detection and identification of red cell
antibodies Cross-matching Modified direct
anti-globulin (affinity) test (DAT) Typing
17CellBind products
- CellBind Screen, 48 cards
- CellBind LISS, 250 mL 100 mL
- CellBind Direct, 96x IgG,C3d,Ctl
- CellBind P2, 2x10 mL
- CellBind P3, 3x10 mL
- CellBind ID16, 16x3 mL