1
UG-crate status
  • AMS TIM - CERN - 15/4/2008
  • A.Bartoloni, B.Borgia, F.R.Spada
  • INFN Roma

2
UG-electronics in the TRD Gas System
3
UG electronics design history
4
QM to QM2 modifications
  • Replace the TPSxxxx regulators with SEL free
    LP2989 (UGBS, UGBC, UGFV)
  • Put limiting resistor on Kulites and GP50 power
    supply lines (UGBS, UGBC)
  • Separate 12V power supply for UGPS and flipper
    valve (UGFV)
  • Introduce LP2953 regulator to generate 24V for
    pumps high speed (UGBP)
  • Introduce LP2953 regulator to generate 21V for
    analog mux (UGBP)
  • Eliminate 3.3V DC-DC converter ? generate
    3.3V from 5V on backplane
  • Introduce Solid State Fuses (SSF) for short
    circuit protection on 5V, on each module
  • Introduce pull-down resistors on Mosfet gates
  • Introduce differential amplifier on Kulite inputs
  • Eliminate UHVG ? redesign of backplane
  • Eliminate 2 UGFV and reduce 8 multiple channels
    to 4 ? redesign of pcb

5
UG electronics test history
  • (1) since then, QM1-UG widely used for the TRD
    gas functional tests
  • (2) SlowControl software used on QM1-UG and for
    QM2-UG functional tests
  • (3) found a few problems in the FM gas circuit
    cabling (pumps and spirometer)
  • (4) found some anomalous behaviour in interaction
    with UGPD - solved

6
QM2 UG-electronics qualification test set-up
TV / EMC CHAMBER
UG CRATE
GAS SYSTEM SIMULATOR
SLOW CONTROL
TEST STATION
29V 12V 5V
7
List of operations for qualification tests
Time needed to perform all commands 15 minutes
8
UG crate in the termal chamber
9
UG crate on the vibration plate
10
Termal test profile
Before vibration
After vibration
11
UG crate being prepared for TV test
12
TVT temperature and pressure profiles
13
EMC test setup
14
EMC test setup
UG crate
UGPD
5.6V, 12V, 29V from UGPD
15
EMC test setup
UG crate
UGPD
Marotta, pumps flipper simulator
16
EMC test setup
28V power supply for UGPD
17
Problems encountered during EMC test
  • CE03 at 15kHz exceeded limit by 3db
  • Inserted a 500 µF capacitor on 29V line to the
    backplane
  • Solved
  • RS03 at 60V/m, 240MHZ lost LeCroy communication
    between UGSCM and UGPD (with UGSCM ? UG crate ok)
  • Elimination of one ground loop on LeCroy bus at
    UGPD
  • Shielded 12V and 29V power cables (originally,
    twisted)
  • Solved

18
Conducted emission around 15 KHz with capacitor
on 29V
19
Summary
  • QM2 was qualified at SERMS, Terni
  • Both the ESS and the TVT showed full
    functionality of the electronics, with stability
    of sensor readings within 0.3-0.4 in all
    temperature ranges
  • Full reports are under preparation by the test
    laboratories
  • Only two modifications will be implemented to the
    FM electronics
  • one 470 µF capacitor on the backplane connected
    to the 29V A and 1 on the 29V B to comply with
    the EMC test
  • 3K O pulldown resistors on RX0A and on RX0B on
    the backplane to avoid feeding static 5V from
    UGSCM to RS232 components in the UGBC
  • The required ECO's will be issued
  • No modifications required by the ESS or by the
    TVT test
  • No modifications required by the functionality
    test performed on the actual gas circuit
  • The spirometer was correctly read, and the pumps
    were correctly operated when correctly connected
  • We require that
  • on the UGPD FM controller S9011A, the grounding 0
    ohm resistor for the return line of the 3.3V be
    removed
  • on the UGSCM FM  the pull-up resistors on RX
    lines be removed

20
UG-electronics schedule
21
BACKUP SLIDES
22
Radiated immunity loss of UGSCM UGPD communication
60 V/m
23
Conducted emissions
24
EM to QM modifications
  • Change power supply 24V ? 30V
  • supply for Kulite, Marotta valves, pumps, heaters
  • Pumps power supply
  • 12V directly from DC-DC converter
  • 24V with step-down circuit 30V ? 24V
  • Heaters on CO2, Xe vessels
  • on/off switches identical to Marotta valves
  • Kulite gauges
  • Dallas T sensors replacing GP-50 T
  • n. 2 dedicated links to USCM
  • No basic circuit modified (ADC, switches, serial
    link, )