EnSite System Comparison with Carto XP - PowerPoint PPT Presentation

1 / 28
About This Presentation
Title:

EnSite System Comparison with Carto XP

Description:

Reduces fluoroscopy and procedure time1,2. Ideal for AF ablation ... Compatible with Stereotaxis Magnetic Assisted Intervention. EnSite Array and EnSite NavX: Yes ... – PowerPoint PPT presentation

Number of Views:2174
Avg rating:3.0/5.0
Slides: 29
Provided by: deano7
Category:

less

Transcript and Presenter's Notes

Title: EnSite System Comparison with Carto XP


1
EnSite System Comparison with Carto XP
2
Why the EnSite System?
  • Map any arrhythmia
  • Open platform 3D navigation of ANY catheter
  • Reduces fluoroscopy and procedure time1,2
  • Ideal for AF ablation
  • Expandable system for future applications
  • Unsurpassed clinical support
  • Lower procedure costs

3
Feature-by-Feature Comparison
4
Single-Beat Noncontact Mapping
  • EnSite Array Yes
  • Single-beat, global activation
  • Nonsustained and unstable arrhythmias
  • Displays computed unipolar or bipolar
    virtual waveforms for any map location
  • Carto XP No

5
Activation and Voltage Mapping
  • EnSite Array and EnSite NavX Yes
  • Diagnostic Landmark Mapping
  • Any standard EP catheter and any electrode
  • 10-beats of data permanently saved
  • Can be used without chamber geometry
  • Diagnostic Landmark maps identify areas of low
    voltage and activation timing
  • Carto XP Yes
  • Only the distal electrode from a Biosense Webster
    catheter can be used
  • 10-beats of data saved only temporarily
  • Electroanatomic mapping identifies areas of low
    voltage and activation timing

6
Dynamic Substrate Mapping
  • EnSite Array Yes
  • Automatically measures substrate potential based
    on user-defined parameters
  • Maps scar zones or lines of conduction block
  • Allows fast and accurate creation of voltage map
    and substrate markers
  • Minimizes user variability
  • Carto XP No

7
Respiration Compensation
  • EnSite NavX Yes
  • Increases procedure accuracy by minimizing the
    effects of respiration
  • Easily re-applied if breathing dramatically
    changes
  • Carto XP No

8
Geometry Creation
  • EnSite Array and EnSite NavX Yes
  • Highly detailed anatomic model only one per
    procedure needed
  • Realtime geometry creation from up to 20
    electrodes simultaneously
  • Modest patient movement does not affect location
    technology or procedure
  • Carto XP Yes
  • Geometry detail tied to acquisition of activation
    timing and voltage data
  • Geometry based on acquisition of one point per
    cardiac cycle
  • Patient movement can disrupt the location
    technology and require that the procedure be
    re-initiated

9
Compatible with Most Diagnostic and Ablation
Catheters
  • EnSite Array Yes
  • Simultaneously displays up to four electrodes
  • EnSite NavX Yes
  • Simultaneously displays up to 64 electrodes on 12
    catheters
  • Carto XP No
  • Limited to Biosense Webster NAVISTAR catheters
  • Limited to two NAVISTAR sensors

10
Used with Cryo Ablation
  • EnSite NavX Yes
  • Carto XP No

11
Compatible with Multiple Generators
  • EnSite Array and EnSite NavX Yes
  • Boston Scientific EPT
  • CryoCath Freezor (EnSite NavX only)
  • Irvine Biomedical (where available)
  • Medtronic Atakr and Atakr II
  • Stockert
  • Carto XP Yes, with limitations
  • Stockert generator recommended
  • Limitations with other generators

12
Compatible with Stereotaxis Magnetic Assisted
Intervention
  • EnSite Array and EnSite NavX Yes
  • Carto XP No may be available in future upgrade

13
EnSite System Product Pipeline
14
EnSite System Version 5.1 Software
  • EnSite Verismo Segmentation Tool support
  • Digital Image import options
  • Clinical enhancements
  • Simultaneous mapping from multiple electrodes
  • Single-beat data from circumferential catheters
    will facilitate faster and easier AF ablation
    procedures
  • Enhanced geometry smoothing
  • Drag and drop anatomic marker tool

15
  • EnSite Verismo Segmentation Tool for Digital
    Image Fusion
  • Simple cardiac segmentation

16
Segmentation
  • Create 3D heart models from spiral CT or MR slice
    data
  • Provide the highest resolution left atrial model
    possible
  • Anatomy validation assists with pre-procedure
    planning

17
EnSite Verismo Segmentation Tool
  • Co-development with Mayo-Biomedical Imaging
    Resource Group
  • Provides fast and easy cardiac segmentation
  • Supports any brand of slice-based MR or Spiral
    CT file (DICOM3)
  • Supports segmentation in EP lab or at another
    site within the hospital

18
EnSite Verismo Segmentation Tool
  • Load any Spiral CT or MRI file (DICOM3 format)

19
Creates 3D Models
  • Click on the blood pool
  • 3D blood pool model appears in upper right

20
Segment Further Anatomy as Needed
  • Add additional objects by the same process

21
Comparison of Registration Tools
22
EnSite Registration Tool
  • CT or MR scan registers with geometry to become
    the anatomic model
  • Activation timing, voltage data, labeling are
    applied to CT/MR model
  • Navigation within CT/MR model

23
Registration Tools Comparison
24
Registration Tools Comparison
25
Registration Tool Development
  • Aggressive and thorough development process in
    progress
  • FDA clearance underway
  • Three-stage 510K IDE study
  • Retrospective human studies
  • Animal studies
  • Prospective human studies
  • Clearance expected in 2006

26
Cost Comparison Atrial Fibrillation
27
Why the EnSite System?
  • Map any arrhythmia
  • Open platform 3D navigation of ANY catheter
  • Reduces fluoroscopy and procedure time1,2
  • Ideal for AF ablation
  • Expandable system for future applications
  • Unsurpassed clinical support
  • Lower procedure costs

28
Guiding the Direction of Cardiac Therapies
Thank You
Write a Comment
User Comments (0)
About PowerShow.com