Title: EnSite System Comparison with Carto XP
1EnSite System Comparison with Carto XP
2Why the EnSite System?
- Map any arrhythmia
- Open platform 3D navigation of ANY catheter
- Reduces fluoroscopy and procedure time1,2
- Ideal for AF ablation
- Expandable system for future applications
- Unsurpassed clinical support
- Lower procedure costs
3Feature-by-Feature Comparison
4Single-Beat Noncontact Mapping
- EnSite Array Yes
- Single-beat, global activation
- Nonsustained and unstable arrhythmias
- Displays computed unipolar or bipolar
virtual waveforms for any map location
5Activation and Voltage Mapping
- EnSite Array and EnSite NavX Yes
- Diagnostic Landmark Mapping
- Any standard EP catheter and any electrode
- 10-beats of data permanently saved
- Can be used without chamber geometry
- Diagnostic Landmark maps identify areas of low
voltage and activation timing
- Carto XP Yes
- Only the distal electrode from a Biosense Webster
catheter can be used - 10-beats of data saved only temporarily
- Electroanatomic mapping identifies areas of low
voltage and activation timing
6Dynamic Substrate Mapping
- EnSite Array Yes
- Automatically measures substrate potential based
on user-defined parameters - Maps scar zones or lines of conduction block
- Allows fast and accurate creation of voltage map
and substrate markers - Minimizes user variability
7Respiration Compensation
- EnSite NavX Yes
- Increases procedure accuracy by minimizing the
effects of respiration - Easily re-applied if breathing dramatically
changes
8Geometry Creation
- EnSite Array and EnSite NavX Yes
- Highly detailed anatomic model only one per
procedure needed - Realtime geometry creation from up to 20
electrodes simultaneously - Modest patient movement does not affect location
technology or procedure
- Carto XP Yes
- Geometry detail tied to acquisition of activation
timing and voltage data - Geometry based on acquisition of one point per
cardiac cycle - Patient movement can disrupt the location
technology and require that the procedure be
re-initiated
9Compatible with Most Diagnostic and Ablation
Catheters
- EnSite Array Yes
- Simultaneously displays up to four electrodes
- EnSite NavX Yes
- Simultaneously displays up to 64 electrodes on 12
catheters
- Carto XP No
- Limited to Biosense Webster NAVISTAR catheters
- Limited to two NAVISTAR sensors
10Used with Cryo Ablation
11Compatible with Multiple Generators
- EnSite Array and EnSite NavX Yes
- Boston Scientific EPT
- CryoCath Freezor (EnSite NavX only)
- Irvine Biomedical (where available)
- Medtronic Atakr and Atakr II
- Stockert
- Carto XP Yes, with limitations
- Stockert generator recommended
- Limitations with other generators
12Compatible with Stereotaxis Magnetic Assisted
Intervention
- EnSite Array and EnSite NavX Yes
- Carto XP No may be available in future upgrade
13EnSite System Product Pipeline
14EnSite System Version 5.1 Software
- EnSite Verismo Segmentation Tool support
- Digital Image import options
- Clinical enhancements
- Simultaneous mapping from multiple electrodes
- Single-beat data from circumferential catheters
will facilitate faster and easier AF ablation
procedures - Enhanced geometry smoothing
- Drag and drop anatomic marker tool
15- EnSite Verismo Segmentation Tool for Digital
Image Fusion - Simple cardiac segmentation
16Segmentation
- Create 3D heart models from spiral CT or MR slice
data - Provide the highest resolution left atrial model
possible - Anatomy validation assists with pre-procedure
planning
17EnSite Verismo Segmentation Tool
- Co-development with Mayo-Biomedical Imaging
Resource Group - Provides fast and easy cardiac segmentation
- Supports any brand of slice-based MR or Spiral
CT file (DICOM3) - Supports segmentation in EP lab or at another
site within the hospital
18EnSite Verismo Segmentation Tool
- Load any Spiral CT or MRI file (DICOM3 format)
19Creates 3D Models
- Click on the blood pool
- 3D blood pool model appears in upper right
20Segment Further Anatomy as Needed
- Add additional objects by the same process
21Comparison of Registration Tools
22EnSite Registration Tool
- CT or MR scan registers with geometry to become
the anatomic model - Activation timing, voltage data, labeling are
applied to CT/MR model - Navigation within CT/MR model
23Registration Tools Comparison
24Registration Tools Comparison
25Registration Tool Development
- Aggressive and thorough development process in
progress - FDA clearance underway
- Three-stage 510K IDE study
- Retrospective human studies
- Animal studies
- Prospective human studies
- Clearance expected in 2006
26Cost Comparison Atrial Fibrillation
27Why the EnSite System?
- Map any arrhythmia
- Open platform 3D navigation of ANY catheter
- Reduces fluoroscopy and procedure time1,2
- Ideal for AF ablation
- Expandable system for future applications
- Unsurpassed clinical support
- Lower procedure costs
28Guiding the Direction of Cardiac Therapies
Thank You