GAMMAPARTICLE ARRAY FOR DIRECT REACTION STUDIES - PowerPoint PPT Presentation

About This Presentation
Title:

GAMMAPARTICLE ARRAY FOR DIRECT REACTION STUDIES

Description:

GAMMA-PARTICLE ARRAY FOR DIRECT REACTION STUDIES. SIMULATIONS. Detection challenges for (d,p) reactions ... In-beam test with the TIARA MUST2 EXOGAM VAMOS array ... – PowerPoint PPT presentation

Number of Views:44
Avg rating:3.0/5.0
Slides: 26
Provided by: bfd
Category:

less

Transcript and Presenter's Notes

Title: GAMMAPARTICLE ARRAY FOR DIRECT REACTION STUDIES


1
GAMMA-PARTICLE ARRAY FOR DIRECT REACTION
STUDIES
  • SIMULATIONS

2
Detection challenges for (d,p) reactions
78Ni(d,p)79Ni _at_ 10 MeV/u
Measurements-gtObservables Ep and/or E? -gtEx ?p
-gt ds/d? -gt (l , SF)
A
Challenges
Energy (MeV)
  • Kinematics compression -gtEp good resolution
  • States separated by 1 MeV -gt200 keV in Ep
  • Covers large range in ?_lab(deg) -gt4pi ang cover
  • Deposit of low Energy-gtThreshold problems
  • Doppler Broadening

?_lab(deg)
3
PHYSICS CASE DIRECT REACTION STUDIES
A
SUB-TASK SINGLE-PARTICLES and COLLECTIVE
PROPERTIES
  • Reactions
  • Elastic and inelastic scattering
  • Transfer reactions

Integrated particle and gamma detection system
Direct reactions studies
  • Key experiments Mapping of single-particle
    energies using transfer reactions
  • 78Ni(d,p)79Ni _at_ 10 MeV/u
  • 132Sn(d,p)133Sn _at_ 10 MeV/u

4
132Sn(d,p)133Sn _at_ 10 AMeV
  • Particle array (Simulations)

5
PARTICLE ARRAY Simple Geometry
INPUT
  • Distance to (0,0,0) 5 cm
  • Box of 4 Silicon detectors
  • Area 1010 cm2
  • Detector Thickness 300um
  • Source of protons with kinematics from reaction
    placed at (0,0,0)
  • No target
  • Energy Resolution
  • Strip pitch size
  • Thickness detector (punch through)
  • Target thickness effect

STUDY of the ?? and ?Ex
6
PARTICLE ARRAY Angular Resolution
If Strip pitch 1mm -gtnumber of channels for 10
cm detector 10010010000 6 detectors 6x10000
channels (pad-type detector) 6 detectors
6x(100100) channels (strip-type)
7
PARTICLE ARRAY Target Effect
Strip pitch and thickness fixed 1mm , 300µm
  • Target thickness
  • 0.5 mg/cm2
  • 1 mg/cm2
  • 2 mg/cm2
  • Source of protons _at_ (0,0,0)

Effect of the angular and energy loss straggling
on the ?? , ?Ex
8
PARTICLE ARRAY Angular Resolution (target in)
9
PARTICLE ARRAY Ex Resolution (target in)
At high energies, emission angles close to 90
degrees, protons see more material
?Ex 140 keV (0.5mg/cm2) ?Ex 170 keV
(1mg/cm2) ?Ex 225 keV (2mg/cm2) _at_4MeV
10
PARTICLE ARRAY Excited States (no target)
132Sn(d,p)133Sn
Excitation energy resolution reconstructed from
the proton energy
11
PARTICLE ARRAY Excited States (target in)
132Sn(d,p)133Sn
  • Effect of the target thickness in the
    Energy-Angle distributions
  • Punch-through at lower Ep
  • Low the Ep due to the energy loss -gtthreshold
  • Increases the ?Ep -gt difficult to separate states

0.5 mg/cm2
1 mg/cm2
2 mg/cm2
1 mg/cm2
0.5 mg/cm2
12
PARTICLE ARRAY Excited States (target in)
Target thickness worsens the resolution in Ex
13
PARTICLE ARRAY INTERACTION POINT
  • Assuming reaction can take place at any Z lt
    Target Thickness
  • X and Y are defined by the beam spot size

1 mg/cm2
1 mg/cm2 inter point
14
PARTICLE ARRAY RANDOM INTERACTION POINT
The main source comes from the uncertainty on the
z-coordinate Beam spot size negligeable
15
EXPERIMENTAL DATA 132Sn(d,p)133Sn at Oak Ridge
Courtesy K. JONES preliminary
160 um/cm2 target of CD2 at 4.7 MeV/u
Data will be an input for the event-generator
-gtRealistic implementation of the cross sections
16
132Sn(d,p)133Sn at 10 AMeV
  • Gamma array (simulations)

17
GAMMA ARRAY VALUES OF GAMMA RAYS IN THE LAB
DOPPLER SHIFT
? 0.2 -gt 10 AMeV E?4 MeV -gt 3.4,4.8 MeV ?
0.3 -gt 35 AMeV E?4 MeV -gt 2.9,5.4 MeV
Tlab(degrees)
?E?/E? tot ?E?/E? int ?E?/E? dop
18
GAMMA ARRAY RESOLUTION DOPPLER BROADENING
E ?lab f(?,?) -gt ?E?/E? dop f(?)
?E?/E? ()
?E?/E? 0.5 E1MeV -gt 5 keV ?? 2o D8
cm Crystal Size ?? 2.8 mm 2o
Tlab(degrees)
3mm for a detector size of 12cm -gt40x40 1600 ch
detector 6 detectors -gt6x 16009600 channels
19
GAMMA ARRAY RESOLUTION INTRINSIC

?E?/E? int
?E?/E? int 13.4 at 662 keV 90keV
Other materials LaBr3(Ce),LaCl2 To be studied
F. Notaristefani NIM A480 (2002) 423-430
20
GAMMA ARRAY SIMPLE GEOMETRY
  • INPUT
  • Distance to (0,0,0) 5 cm
  • Area 1010 cm2
  • Detector Thickness 3 cm
  • Source of gamma rays placed at (0,0,0)

Z
21
GAMMA ARRAY Gamma resolution
Meausrement of gamma rays in coincidence with
particle is mandatory when dealing with thick
targets.
22
GEOMETRY Preliminary
M. Labiche
23
FURTHER WORK
  • Study of different materials for the Calorimeter
  • Implement realistic cross sections in the
    event-generator
  • In-beam test with the TIARAMUST2EXOGAMVAMOS
    array
  • Implement realistic geometry to determine
    efficiencies

24
PARTICLE ARRAY Thickness detector
15000 µm thick 40 times thicker t
400 µm thick
200 µm thick
The tickness determines the upper limit in Total
energy and angle before the particles
punch-through. The energy rises steadily and
therefore not much gain in angular distributions
25
PARTICLE ARRAY Ex Resolution
Exf(Ep,?)
Write a Comment
User Comments (0)
About PowerShow.com