Title: Insecticides analysis


1
Insecticides analysis
  • Dr. N.K. Ponkshe
  • Head Quality
  • Bayer CropScience

2
Insecticides
  • Differentiation is generally based on Chemical
    family of the molecule
  • Classical , Newer types
  • Poly halogenated
  • Carbamates , dithiocarbamates
  • Organophosphorus
  • Pyrethroids
  • Triazines
  • Urea derivatives
  • Newer types CNIs , Cycloprop esters , Azoles ,

3
  • Analytical procedures depend on the type of
    molecules
  • Ranging from
  • Chemical method of estimation involving
    hydrolysis , or absorbing the gas evolved ,
    titrimetry etc .
  • Instrumental methods based on the functional
    group present in the molecule .
  • UV , IR , Colourimetry , etc
  • GLC and HPLC

4
  • As the molecule chemistry has advanced , so are
    the testing methods
  • Newer formulation types where
  • Potency has increased
  • Dosages have reduced
  • Loading of AI , depending upon the formulation
    type is changing
  • Molecules with Newer chemistry demand
  • -- highly sophisticated instrumentation
  • ---special techniques and
  • -- most importantly expertise

5
  • Constraints
  • Availability of analytical procedures non
    availability of BIS specs
  • Necessary instrumentation
  • Non availability of reagents of specific quality
  • Solvent systems / gradients
  • Ref grade standards
  • Proper storage facility of ref grade standards
  • Training

6
Result
  • Constraints Methods based on instrumental
    analysis can lead to
  • Inaccurate absorptions
  • Improper resolution of the peaks
  • Incorrect areas marked for peaks under
    consideration
  • Non repeatability in successive measurement /
    injections Errors in areas
  • All the above or even a single factor can lead to
    A wrong outcome

7
Corrective action
  • Using ref grade standards from a reliable source
    Manufacturer
  • Adopt correct instrumental conditions
  • Due care must to be taken while storing ref
    standards
  • Follow recommended analytical procedures ( use
    internal standards wherever recommended )
  • Advantage of using internal standard Error
    gets minimized to a great extent
  • Carry out analysis in duplicate
  • Training / Validation of method / Demonstration

8
  • Thanks !