Title: Barrel Calorimeter Status Quo
1Barrel Calorimeter Status Quo
- Zisis Papandreou
- University of Regina
- GlueX Collaboration Meeting
- JLab, December 11-13, 2003
2Outline
- BCAL Module Prototyping
- 2-m Module-0 Construction Tests
- 4-m Module-1 Preparations
- BCAL Readout RD
- HPD Review
- SiPM Test Results
32-m Module-0
- Great crew of undergraduates
- Construction Completed
- 200cm (l) x 13cm (w) x 17cm (t)
- 180kg
- Polishing Completed
- Preliminary Tests with Cosmics
4Module-0 The Matrix
- Construction method
- Tricks, Dos and donts
- Method is under control
- Minor RD required for 4-m Module-1
52-m Gluing Pressing Process
All that glue for GlueX.
6Trickery rewards
Vaseline to the rescue
7The Ruler Test
8When you least expect it
Big Brother is watching!
9Matrix Reloaded
- 2-m testing with cosmics and beam (Serpukov/Hall
B?) - 1-m prototype with Scintillator sheets (IU).
- 4-m prototype construction at CSR/UofA
- MOU with UofA signed.
- Softer Pb received (Vulcan), Epoxy (Bicron)
- 100-km fibers arrived snag in shipment
- 4.5-m press, Cutting, Spooling Design
- Preparations at UofA are underway for 4m work
- Timetable completion August 2004?
10Pure Leadnow
Now thats a toilet paper roll!
11BananaProblemis solved
12Lead Cutter
- - 2m prototype
- 4m next
- multiple track
13Spooling RD
Hair salon? Combs nonetheless!
14Cosmic Tests (Vitaly Kovaltchouk)
15ADC Spectra
PRELIMINARY
16TDC Spectra
??550 ps
??670 ps
PRELIMINARY
17And what about the readout?
- 2 Tesla field field gradient
- Compact design cost considerations
- Technology
- Hybrid Photo Diode Review
- Silicon Photo Multiplier New Tests
- Multi Channel Plates?
- Avalanche Photo Diodes?
18HPD Measurements (Vitaly Kovaltchouk, Keith
Wolbaum, Garth Huber)
- HPD gain is 1600 preamp, amp-shaper needed
- Noise Setup is sensitive but under control
- Light sources
- Xe-N flasher its RF interfers requires
shielding - NaI crystal and 241Am, 137Cs and 60Co sources
- LED (pulsed) neutral density filter, fiber
lightguide - Measurements HPD PP0350G with Multi-Channel
Analyzer (Tektronix 5200) - Bottom line system works, rise time poor, energy
resolution modest, components are expensive
19Compact but expensive
2001
20Pre-amp and board
21Rise Time vs. External Capacitor
- Light Source Nanosecond Broad-Spectrum Optical
Pulse Radiator (Model NR-1A) and Laser Pulse
Simulator (Model LPS-1A), HV 20 kV. - HPMT A 25 mm proximity focused single pixel
Hybrid Photo Diode equipped, with an S20UV
photo-cathode on a quartz input window, HV 8 kV,
Bias 75 V. Silicon diode capacitance 200 pF.
Tube Type Cexternal (pF) Rise Time (ns) Amplitude (mV) MCA Channel Noise (mV)
DEP 350G 22000 150 1300 950 3
10000 150 1400 1100 3
200 100 600 500 3
100 55 400 310 3
50 40 250 210 3
25 35 120 100 3
Burle 8875 0 lt10 8000 - 2
22MCA Spectrum (LED)
LED off
LED on
23241Am Spectrum
13 energy resolution
Vitaly Kovaltchouk
24SiPM a new Sheriff in town
- Multi pixel silicon photo diode
- Micro pixels (20-30?m) on common load
- 500 pixels in 1mm2 area
- Operates in Geiger mode 106 gain
- Provided by Moscow Engineering and Physics
Institute
25HPD vs. PMT
26SiPM vs. PMT
Optitron Xe-N Plasma Discharge Tube
27Timing resolution
SiPM
PMT
140 ps
375 ps
28Energy resolution
Xe-N Lecroy 612A
90Sr on Scintillating Fiber
1 pe
Low light
Scint Light
2 pe
signal
3 pe
noise
29SiPM in a nutshell
- Very promising readout for BCAL
- Better timing and energy resolution than standard
2 PMTs - 50 prototypes, 1 for bulk orders?
- Tests to come
- Couple to Module-0 and measure
- Test in high magnetic field (MRI?)
- Radiation hardness
- Geometrical packing (Winston cones, wavelength
shifters ? funnel light down)
30So, where are we?
- Matrix construction is well in hand
- 2-m test cosmic results available soon
- 4-m will have modest RD obstacles
- Construction site (UofR, UofA)
- Readout type may have been found
- SiPM very suitable (MCP, APD?)
- Frame and integration issues outstanding