1
First Comparison HARP with GEANT4 Target
Simulations
UK Neutrino factory Meeting 3 May 2006 Kenny
Walaron, Paul Soler University of Glasgow/RAL
2
Comparison G4/MARS hadronic models
  • There were many comparisons of Geant4 and Mars15
    with target simulations
  • Problem no good agreement amongst different
    hadronic models of Geant4 and Mars.

3
Comparison G4 with HARP
  • HARP have published one paper with 12.9 GeV/c
    protons on a 5 LI Aluminium target in forward
    direction (ie.30-210 mrad)
  • Developed simulation of HARP target on G4 and
    compared to yields from HARP paper under same
    assumptions
  • Caveat so far have neglected reabsorption in
    target but should be 5

Deficit G4 1.5-4 GeV/c
30-60 mrad
60-90 mrad
Very preliminary
4
Comparison G4 with HARP
  • HARP have published one paper with 12.9 GeV/c
    protons on a 5 LI Aluminium target in forward
    direction (ie.30-210 mrad)
  • Developed simulation of HARP target on G4 and
    compared to yields from HARP paper under same
    assumptions
  • Caveat so far have neglected reabsorption in
    target but should be 5

Deficit G4 1.5-4 GeV/c
90-120 mrad
120-150 mrad
Very preliminary
5
Comparison G4 with HARP
  • HARP have published one paper with 12.9 GeV/c
    protons on a 5 LI Aluminium target in forward
    direction (ie.30-210 mrad)
  • Developed simulation of HARP target on G4 and
    compared to yields from HARP paper under same
    assumptions
  • Caveat so far have neglected reabsorption in
    target but should be 5

Deficit G4 1.5-4 GeV/c
150-180 mrad
180-210 mrad
Very preliminary
6
Comparison G4 with HARP
  • HARP have published one paper with 12.9 GeV/c
    protons on a 5 LI Aluminium target in forward
    direction (ie.30-210 mrad)
  • Developed simulation of HARP target on G4 and
    compared to yields from HARP paper under same
    assumptions
  • Caveat so far have neglected reabsorption in
    target but should be 5

Total cross-section vs angle
Total cross-section vs momentum
Very preliminary
7
Outlook
  • We have started to compare HARP data to GEANT4
  • So far, all distributions are very preliminary.
    We have not carried out any cross-checks to
    ensure we are doing things identically to HARP
  • Deficit of G4 simulation between 1.5-4 GeV/c
    respect to HARP
  • Some differences in total cross-sections that we
    dont understand
  • Need to compare to MARS simulations as well.