Title: RAD120 Random Access Device
1RAD120Random Access Device
2RAD 120
RAD120 is the new diagnostic system developed for
the total automation of immunoassays, for a
quicker response time and a gain in flexibility
for the main routine tests in Endocrinology,
Tumor Markers, Infectious Disease and Allergy.
3Technology
- Patented Technology
- Pegasus
4Technology
- Solid Phase Magnetic Particles
- coated with
- zirconium with
- high binding capacity towards biologically active
molecules
granting a rapid and effective separation of
free/bound fractions
5System Features
- Fluorescence reading through magnetic particles
solid phase - Continuous loading
- Up to 120 test/h
- Walk away 400 test
- 20 different methods on board
- 20 reagents online
6System Features
- Incubation 180 positions station
- Automatic Predilution and dilution f outside
range samples - Rerun
- Reflex test
- STAT
7I.O.A. ModeThe special I.O.A. mode enables to
introduce resources in the workflow straight from
an intermediate zone, without interferring or
compromising the tests analytical sequence
(Intermediate Operational Area)
8I.O.A. Mode
(Intermediate Operational Area)
9I.O.A. Mode (Intermediate Operational Area)
The special pre-sampling mode reduces the
standing time of the samples in the system,
making them available for other analysis
10Reagents
- Dedicated reagent pack
- 100, 150 or 200 tests
- Barrel (solid phase)
- Wedge, 1 conjugate
- Wedge 2 other reagents
- Ready to use fluids
11Reagents
- 20 Barcode identifiable positions
- 3 months stability on board
- Refrigerated reagents plate
- at 4 8C
- Special lift allows to set
- reagents on board and to
- introduce them i the workflow
- with no interruption to the system productivity.
12Samples
- Random and batch mode
- Continuous Loading
- 6 Racks
- 20 samples (12 mm tubes)16 samples (16 mm tubes)
13Samples
- Possibility to load up to 6 racks (120-96 tubes)
- STAT mode for patient and test
- No dedicated STAT position necessary
14Calibrators
- Calibration curve contained in a ready to use
pack - Two points calibration on Master Curve and two
- control points
- Calibration stable for up to
- four weeks
15Substrate
The appropriate rotating rack allows to replace
the substrate buffer without interruption to
workflow
16Cuvettes
- Reaction /prediluition cuvettes placed on four
racks - 56 positions each
- Easily loaded and unloaded at any time
17Waste
- Solid and liquid waste station
18Quality Control
- Internal Quality Control management
- System applying Westgard rules and Levy-
- Jennings charts
19- Historical Patient Record
- Session printing and final patient report
20Software
- Multitask and multilanguage interface
- Operating system Windows XP or superior
- Touch Screen monitor
- Wireless mouse and keyboard
- Reflex test
21Products Panels
- Thyroid Function
- TSH-3
- T4
- FT4
- T3
- FT3
- TGAB
- TG
- TPOAb
- Fertility
- hCG
- LH
- FSH
- Prolactin
- Estradiol
- Progesterone
- Testosterone
22Products Panels
- Tumor Markers
- APF
- CEA
- TM-Ov (Ca 125)
- TM-Br (Ca15.3)
- TM-Gi (Ca 19.9)
- Total-PSA
- Free PSA
- Ferritin
- TG
- ß2-Microglobulin
- Autoimmunity
- ANA
- ENA-6
- RF
- Ds-DNA
23Products Panels
- Infectivity
- Toxoplasma IgG
- Toxoplasma IgM
- Rubella IgG
- Rubella IgM
- CMV IgG
- CMV IgM
- HSV1 IgG
- HSV2 IgG
- HSV12 IgM
- H. pylori IgG
24RAD120Random Access Device