Title: Vertical-flexure CCD module: Thermal and Dynamic FEA
1Vertical-flexure CCD moduleThermal and Dynamic
FEA
- Bruce C. Bigelow
- University of Michigan
- Department of Physics
- 10/28/04
2Vertical-flexure CCD module
- Objectives
- Accommodate Moly-Invar CTE mismatch with
vertical flexure Moly CCD mount (see previous
presentation) - Demonstrate acceptable thermal stresses for
package over survival temperature range - Demonstrate acceptable modal performance for
package
3CCD module FEA
4CCD module FEA
5CCD module FEA
6Vertical-flexure module FEA
- Analyses
- Neglect AlN, silicon from models (TZM and Invar
only) - No pre-stress of package at room temp
- TZM Flexure geometry (not optimized)
- Blade thickness 0.4 mm (0.016)
- Blade width 8 mm (0.32)
- Blade effective length 4 mm (0.16)
- Thermal
- Simple delta-T -160K, constant CTEs
- Frame constrained for zero mounting stress
- Dynamic
- Mounting pads constrained
- TZM Flexure to Invar joint nodes coupled
7CCD module FEA - elements
8Vertical-flexure module FEA
- Analyses
- Thermal
- Simple DT -160K, constant CTEs
- Frame constrained for zero base stress at
mounting - Flexures and Invar base interface nodal
deflections coupled at centerline to simulate
single screw constraints (very conservative
neglects screw head constraint) - Z constraints coupled at top of Invar surface
(worst case)
9CCD module FEA node couples
10CCD module FEA frame stress
Max stress in flexures 132 MPa 19,410 PSI
(TZM Sy 860 MPa)
11CCD module FEA Invar stress
Max stress in Invar 5.6 MPa 812 PSI (Invar Sy
300 MPa)
12CCD module FEA - elements
Max distortion of Invar base (CCD mounting
surface) is 0.1 micron
13Vertical-flexure module FEA
- Analyses
- Dynamic
- Modal analysis, reduced (Householder) modal
extraction - TZM - Invar interface nodal deflections coupled
as in thermal case - First 10 frequencies
- SET TIME/FREQ
- 1 3279.8
- 2 3458.6
- 3 3955.8
- 4 5009.2
- 5 6928.7
- 6 7684.2
- 7 8830.7
- 8 9707.0
- 9 12753.
- 10 13239.
14CCD module FEA - Dynamic
15CCD module FEA - Dynamic
16CCD module FEA - Dynamic
17Vertical flexure CCD module
- Conclusions
- Thermal and dynamic FEA presented
- Low thermal stresses demonstrated with
non-optimized TZM flexures - High resonant frequencies demonstrated with
non-optimized TZM flexures - Optimal flexure dimensions still TBD for minimal
stress and maximum first resonance