1
Bad Boards 6-May-03
  • 574 CFTA 8B6 several dead channels
  • 553 CFTS 3B1 in SVX0 sift 2 has large RMS
  • 656 FPS 1A2 many problems with 2 sifts in SVX7
  • 670 FPS 2A6 bad bias read-back
  • 713 FPS 2A7 bias read-back 0, cryo read-back
    nonsense, no entries to hit map
  • 548 CFTA 7A2 Unbiased VLPC?
  • 462 CFTA 6A2 Unbiased VLPC?
  • 622 CPS BA6 Unbiased VLPC?
  • 624 CPS AA6 Unbiased VLPC?
  • 513 CFTA 8B3 Major alarm on bias PV-SP-1.6V
  • 551 CFTS 2B1 Major alarm on bias PV-SP2.4V
  • 541 CFTS BA5 Major alarm on bias PV-SP-1.2V
  • 647 CPS 3B3 Major alarm on bias PV-SP-0.35V

2
Board in slot 8B6
  • There were 12 dead channels in this region

3
Temperature oscillating in 7B5 module 8
  • Stopped oscillating after re-inserting of bayonet

4
7B5 module 8 temperature does not oscillate any
more
5
Problem with cassette?
  • 3B1 did not improve after boards swap

6
Crate 0x53
  • 7-May crate 0x53 taken out of run because of
    missing events
  • Changed mezzanine board did not fix
  • 8-May new VRBC installed, new VRB firmware
    installed
  • 9-May crate 0x53 back in global run

7
Missing Events in 0x52 and 0x53
  • New VRBC in ox53, old in 0x52
  • 14-May-03 to 19-May-03
  • Crate 0x52 6 times
  • Crate 0x53 5 times
  • Crate 0x52 power-cycled once to get rid of Sync
    error
  • Init VRBC fixes the problem

8
Cft_examine
  • Will be improved
  • Hit maps for SVX hits only
  • Hit maps after applying Svx reco thresholds

9
FPD
  • 2 afe boards read-out by last VRB in crate 0x52

10
FPD talking points
  • Are fpd boards in the run?
  • Yes (as long as fpd VRB not entirely yellow)
  • Change configuration of fpd system
    (disable/enable fpd boards in cft_gui)
  • No. Have you just changed hardware configuration
    on the platform ? Anyway this would have to be
    followed by calibration which is not my job
  • Download crate 0x52
  • Is FPD examine showing new problems, gray color
    is okay too
  • Calibrate crate 52
  • Crate 0x52 is always calibrated, anyway this is
    not my job

11
Intermittent Alarms on 7A5 module 7
  • AFE board 7A5 is connected to west-most cassette
    in EAST cryostat, only modules 5-8 are connected
    to detector
  • This cassette is known to be the warmest and
    temperature fluctuations generate intermittent
    alarms
  • CFTA_AFE_7A5/TCOV7
  • Persistent alarms generated by this board require
    adjustment of cryostat temperature

12
Disabled AlarmsTalking points with Captains
  • We have 29 Disabled Alarms, in total cft has few
    thousands of possible alarms
  • It will take time to get rid of them, they
    require work on the platform
  • Most of them are believed to be failures in
    read-back circuit