COLTRI SUB
  • OXYTRONIC 600
  • CONTINUOUS FLOW NITROX SYSTEM

2
COLTRI SUB
  • SAFETY

3
WARNINGS
  • OPERATORS OF THE OXYTRONIC 600 NEED TO BE
    CERTIFIED GAS BLENDERS
  • READ THE MANUAL BEFORE USING THE SYSTEM
  • THE OPERATOR MUST STAY IN VISUAL RANGE OF THE
    SYSTEM
  • THE MAXIMUM OXYGEN PERCENTAGE IS 40
  • OXYTRONIC 600 MUST BE MAINTAINED BY AUTHORIZED
    AND TRAINED PERSONNEL

4
TABLE OF CONTENTS
  • ADVANTAGES OF SYSTEM
  • FEATURES OVERVIEW
  • ASSEMBLY INSTRUCTIONS
  • SET-UP PROCEDURES
  • OPERATING PROCEDURES
  • BLENDING SOFTWARE

5
COLTRI SUB
  • ADVANTAGES OF SYSTEM

6
ADVANTAGES OF SYSTEM
  • OXYTRONIC 600 HAS A MAXIMUM APPLICATION OF 600L
    PER MINUTE
  • NO WASTAGE OF OXYGEN
  • LOW PRESSURE BLENDING MINIMIZES THE NEGATIVE
    AFFECTS OF REAL GAS LAWS
  • SIMPLE SWITCHING BETWEEN BLENDS
  • NO O2 CLEAN EQUIPMENT REQUIRED
  • NO WASTAGE OF REMAINING GASES IN USED TANKS
  • BLENDS CAN BE USED IMMEDIATELY. NO NEED TO WAIT
  • EXTREMELY ACCURATE BLENDS CAN BE ACHIEVED

7
COLTRI SUB
  • FEATURES OVERVIEW

8
FEATURES OVERVIEW
  • ACCUTRONIC INTELLIGENT SENSOR
  • MAXIMUM PERCENTAGE SAFETY LIMITER
  • MIXING RANGE ALARM
  • NO FLOW ALARM
  • MECHANICAL GAS VALVE
  • EASY TO READ DISPLAY

9
ACCUTRONIC INTELLIGENT SENSOR
  • The lifespan of the oxygen sensor can be
    calibrated and checked by the user frequently
    ensuring constantly accurate blends

10
MAXIMUM PERCENTAGE SAFETY LIMITER
  • The User can program the Oxytronic 600 with a
    maximum allowable percentage for oxygen in the
    mix which ensures very high safety levels when
    blending with oxygen

11
MIXING RANGE ALARM
  • A red LED alarm controls the mixing range of the
    Oxytronic 600 and will light up when the set
    percentage varies by 1

12
NO FLOW ALARM
  • The power supply of the Oxytronic 600 can be
    connected to your compressor ensuring that NO
    oxygen flows when your compressor is not running,
    ensuring maximum safety and economy of gases
  • A green LED will light up showing the NO flow
    alarm

13
MECHANICAL GAS VALVE
  • A mechanical control valve at the entry point to
    the Oxytronic 600 allows the user to control gas
    flow even when the oxygen tanks are in a
    different room from the facility where the
    compressor is installed

14
EASY TO READ DISPLAY
  • The large easy to read LCD and alarm lights of
    the Oxytronic 600 facilitate usage and control of
    the system, allowing the user to carry on with
    other tasks while remaining in close proximity to
    the system
  • THE USER MUST REMAIN IN
  • VISUAL RANGE AT ALL TIMES

15
COLTRI SUB
  • ASSEMBLY

16
ASSEMBLY INSTRUCTIONS
  • MOUNT THE STAINLESS STEEL PLATE TO THE WALL

SCREW TO WALL
17
ASSEMBLY INSTRUCTIONS
  • MOUNT THE STAINLESS STEEL PLATE TO THE WALL
  • HANG THE OXYTRONIC 600 ON THE 4 MOUNTING BOLTS

SCREW TO WALL
HANG ON BOLT
18
ASSEMBLY INSTRUCTIONS
  • ENSURE THE POWER SUPPLY IS SET TO 12 VOLTS

ADJUST TO 12V
19
ASSEMBLY INSTRUCTIONS
  • ENSURE THE POWER SUPPLY IS SET TO 12 VOLTS
  • POLARITY ON THE JACK PLUG SHOULD BE
  • INSIDE AND
  • OUTSIDE AS IN THIS DIAGRAM

POLARITY
20
ASSEMBLY INSTRUCTIONS
  • ENSURE THAT THERE IS A POWER POINT NEARBY
    PREFERABLY WITH CURRENT SUPPLIED FROM THE
    COMPRESSOR.

21
ASSEMBLY INSTRUCTIONS
  • ENSURE THAT THERE IS A POWER POINT NEARBY
    PREFERABLY WITH CURRENT SUPPLIED FROM THE
    COMPRESSOR.
  • CONNECT THE POWER SUPPLY TO OXYTRONIC 600

JACK PLUG
22
ASSEMBLY INSTRUCTIONS
  • CONNECT THE OXYGEN CLEAN HOSE TO THE QUICK
    CONNECTOR OF THE OXYTRONIC 600

QUICK CONNECT
23
ASSEMBLY INSTRUCTIONS
  • CONNECT THE OTHER END OF THE OXYGEN CLEAN HOSE TO
    THE OXYGEN REGULATOR AND ATTACH TO O2 BOTTLE
  • ENSURE ALL CONNECTIONS ARE CLEANED WITH
    COMPATIBLE CLEANING MATERIALS BEFORE CONNECTION

PUSH ON TO CONNECT
24
ASSEMBLY INSTRUCTIONS
  • CONNECT THE CORRUGATED HOSE TO THE INLET OF THE
    COMPRESSOR (REDUCING ELBOW SUPPLIED) AND THE
    OTHER END TO THE OUTLET OF THE OXYTRONIC 600
  • CLAMP BOTH ENDS TIGHTLY WITH SUPPLIED CLAMPS

25
ASSEMBLY INSTRUCTIONS
  • PLUG THE TRANSFORMER INTO THE POWER SUPPLY AND
    THE JACK PLUG INTO THE OXYTRONIC 600

26
ASSEMBLY INSTRUCTIONS
  • PLUG THE TRANSFORMER INTO THE POWER SUPPLY AND
    THE JACK PLUG INTO THE OXYTRONIC 600
  • TURN ON THE KEY SWITCH

ON SWITCH
27
ASSEMBLY INSTRUCTIONS
  • PLUG THE TRANSFORMER INTO THE POWER SUPPLY AND
    THE JACK PLUG INTO THE OXYTRONIC 600
  • TURN ON THE KEY SWITCH
  • HOLD DOWN THE ON BUTTON FOR 2 SECONDS

ON BUTTON
28
ASSEMBLY INSTRUCTIONS
  • PLUG THE TRANSFORMER INTO THE POWER SUPPLY AND
    THE JACK PLUG INTO THE OXYTRONIC 600
  • TURN ON THE KEY SWITCH
  • HOLD DOWN THE ON BUTTON FOR 2 SECONDS
  • BOTH RED AND GREEN LED'S WILL LIGHT UP
  • THE OXYTRONIC 600 IS NOW ASSEMBLED

29
COLTRI SUB
  • SET-UP

30
SET-UPPROCEDURES
  • WHEN OPERATING FOR THE FIRST TIME OR AFTER
    CHANGING SENSORS, YOU NEED TO CALIBRATE THE
    ACCUTRONIC INTELLIGENT SENSORS REMAINING LIFE

31
SET-UPPROCEDURES
  • WHEN OPERATING FOR THE FIRST TIME OR AFTER
    CHANGING SENSORS, YOU NEED TO CALIBRATE THE
    ACCUTRONIC INTELLIGENT SENSORS REMAINING LIFE
  • TURN ON KEY SWITCH

ON SWITCH
32
SET-UPPROCEDURES
  • WHEN OPERATING FOR THE FIRST TIME OR AFTER
    CHANGING SENSORS, YOU NEED TO CALIBRATE THE
    ACCUTRONIC INTELLIGENT SENSORS REMAINING LIFE
  • TURN ON KEY SWITCH
  • PRESS AND HOLD CALIBRATE BUTTON

CALIBRATE
33
SET-UPPROCEDURES
  • WHEN OPERATING FOR THE FIRST TIME OR AFTER
    CHANGING SENSORS, YOU NEED TO CALIBRATE THE
    ACCUTRONIC INTELLIGENT SENSORS REMAINING LIFE
  • TURN ON KEY SWITCH
  • PRESS AND HOLD CALIBRATE BUTTON..
  • PRESS ON BUTTON AND HOLD BOTH FOR 15 SECONDS

ON BUTTON
34
SET-UPPROCEDURES
  • WHEN OPERATING FOR THE FIRST TIME OR AFTER
    CHANGING SENSORS, YOU NEED TO CALIBRATE THE
    ACCUTRONIC INTELLIGENT SENSORS REMAINING LIFE
  • TURN ON KEY SWITCH
  • PRESS AND HOLD CALIBRATE BUTTON
  • PRESS ON BUTTON AND HOLD BOTH FOR 15 SECONDS
  • 3 BEEPS WILL SOUND SAVING TENSION IN THE SENSOR

35
SET-UPPROCEDURES
  • BEFORE USING OXYTRONIC 600 FOR THE FIRST TIME YOU
    NEED TO TEST THE SYSTEM BY CHECKING THE
    ELECTRONIC VALVE
  • THIS CAN BE DONE BY COMPLETING THE FOLLOWING
    PROCEDURES

36
CHECKINGELECTRO VALVE
  • REPEAT TEST FREQUENTLY TO ENSURE VALVES ARE
    WORKING CORRECTLY

37
CHECKINGELECTRO VALVE
  • SWITCH ON COMPRESSOR

38
CHECKINGELECTRO VALVE
  • SWITCH ON COMPRESSOR
  • ENSURE MECHANICAL VALVE IS CLOSED

MECHANICAL VALVE
39
CHECKINGELECTRO VALVE
  • SWITCH ON COMPRESSOR
  • ENSURE MECHANICAL VALVE IS CLOSED
  • ENSURE OXYGEN FLOW REGULATOR IS CLOSED

O2 REG
40
CHECKINGELECTRO VALVE
  • SWITCH ON COMPRESSOR
  • ENSURE MECHANICAL VALVE IS CLOSED
  • ENSURE OXYGEN FLOW REGULATOR IS CLOSED
  • OPEN O2 VALVE

OPEN O2 VALVE
41
CHECKINGELECTRO VALVE
  • SWITCH ON COMPRESSOR
  • ENSURE MECHANICAL VALVE IS CLOSED
  • ENSURE OXYGEN FLOW REGULATOR IS CLOSED
  • OPEN O2 REGULATOR
  • SET INTERMEDIATE PRESSURE ON O2 VALVE TO 5 BAR
    (SEE PAGE 68)

SET PRESSURE
42
CHECKINGELECTRO VALVE
  • SWITCH ON COMPRESSOR
  • ENSURE MECHANICAL VALVE IS CLOSED
  • ENSURE OXYGEN FLOW REGULATOR IS CLOSED
  • OPEN O2 REGULATOR
  • SET INTERMEDIATE PRESSURE ON O2 VALVE TO 5 BAR
  • TURN ON SWITCH

TURN ON
43
CHECKINGELECTRO VALVE
  • SWITCH ON COMPRESSOR
  • ENSURE MECHANICAL VALVE IS CLOSED
  • ENSURE OXYGEN FLOW REGULATOR IS CLOSED
  • OPEN O2 REGULATOR
  • SET INTERMEDIATE PRESSURE ON O2 VALVE TO 5 BAR
    (SEE PAGE 28)
  • TURN ON SWITCH
  • PRESS ON BUTTON (GREEN LED WILL ILLUMINATE)

PRESS ON
44
CHECKINGELECTRO VALVE
  • OPEN MECHANICAL GAS VALVE

OPEN
45
CHECKINGELECTRO VALVE
  • OPEN MECHANICAL GAS VALVE
  • OPEN OXYGEN FLOW REGULATOR, O2 WILL SLOWLY
    INCREASE

OPEN VALVE
46
CHECKINGELECTRO VALVE
  • OPEN MECHANICAL GAS VALVE
  • OPEN OXYGEN FLOW REGULATOR, O2 WILL SLOWLY
    INCREASE
  • GAS WILL FLOW FROM THE OXYTRONIC 600 AND YOU WILL
    HEAR INTAKE NOISE OF GAS

47
CHECKINGELECTRO VALVE
  • OPEN MECHANICAL GAS VALVE
  • OPEN OXYGEN FLOW REGULATOR, O2 WILL SLOWLY
    INCREASE
  • GAS WILL FLOW FROM THE OXYTRONIC 600 AND YOU WILL
    HEAR INTAKE NOISE OF GAS
  • CLOSE KEY SWITCH, OXYGEN WILL STOP FLOWING, O2
    PERCENTAGE WILL DROP TO 21

SWITCH OFF
48
SETTINGMAXIMUM O2
  • DO NOT USE HIGHER PERCENTAGES THAN 40

49
SETTINGMAXIMUM O2
  • TURN ON KEY SWITCH

TURN ON
50
SETTINGMAXIMUM O2
  • TURN ON KEY SWITCH
  • PRESS AND HOLD IMPOST-ALARM BUTTON

PRESS HOLD
51
SETTINGMAXIMUM O2
  • TURN ON KEY SWITCH
  • PRESS AND HOLD IMPOST-ALARM BUTTON
  • PRESS ON BUTTON

PRESS ON BUTTON
52
SETTINGMAXIMUM O2
  • TURN ON KEY SWITCH
  • PRESS AND HOLD IMPOST-ALARM BUTTON
  • PRESS ON BUTTON
  • MAX O2 WILL BE SHOWN ON DISPLAY

DISPLAY
53
SETTINGMAXIMUM O2
  • TURN ON KEY SWITCH
  • PRESS AND HOLD IMPOST-ALARM BUTTON
  • PRESS ON BUTTON
  • MAX O2 WILL BE SHOWN ON DISPLAY
  • PRESS (CALIBRATE/-) BUTTON OR (OFF/) BUTTON
    UNTIL DESIRED MAXIMUM IS OBTAINED

OR - BUTTONS
54
SETTINGMAXIMUM O2
  • TURN ON KEY SWITCH
  • PRESS AND HOLD IMPOST-ALARM BUTTON
  • PRESS ON BUTTON
  • MAX O2 WILL BE SHOWN ON DISPLAY
  • PRESS (CALIBRATE/-) BUTTON OR (OFF/) BUTTON
    UNTIL DESIRED MAXIMUM IS OBTAINED
  • PRESS (SENSOR/LIFE-ESC) TO CONFIRM

SENSOR LIFE
55
SETTINGMAXIMUM O2
  • DISPLAY WILL SHOW APPROXIMATE 12V OF BATTERY

/- 12V
56
SETTINGMAXIMUM O2
  • DISPLAY WILL SHOW APPROXIMATE 12V OF BATTERY
  • DISPLAY WILL THEN SHOW CURRENT O2

57
SETTINGMAXIMUM O2
  • DISPLAY WILL SHOW APPROXIMATE 12V OF BATTERY
  • DISPLAY WILL THEN SHOW CURRENT O2
  • THIS MAXIMUM REMAINS SAVED EVEN IF MACHINE IS
    SWITCHED OFF

58
MEASUREMENT OF SENSOR
  • THE STATE OF THE ACCUTRONIC SENSOR CAN BE
    MEASURED FROM TIME TO TIME
  • TURN ON THE OXYTRONIC 600
  • LET AIR PASS FOR A FEW MINUTES

59
MEASUREMENT OF SENSOR
  • THE STATE OF THE ACCUTRONIC SENSOR CAN BE
    MEASURED FROM TIME TO TIME
  • TURN ON THE OXYTRONIC 600
  • LET AIR PASS FOR A FEW MINUTES
  • PRESS CALIBRATE BUTTON

CALIBRATE BUTTON
60
MEASUREMENT OF SENSOR
  • THE STATE OF THE ACCUTRONIC SENSOR CAN BE
    MEASURED FROM TIME TO TIME
  • TURN ON THE OXYTRONIC 600
  • LET AIR PASS FOR A FEW MINUTES
  • PRESS CALIBRATE BUTTON
  • PRESS SENSOR LIFE BUTTON

SENSOR BUTTON
61
MEASUREMENT OF SENSOR
  • THE STATE OF THE ACCUTRONIC SENSOR CAN BE
    MEASURED FROM TIME TO TIME
  • TURN ON THE OXYTRONIC 600
  • LET AIR PASS FOR A FEW MINUTES
  • PRESS CALIBRATE BUTTON
  • PRESS SENSOR LIFE BUTTON
  • FOUR NUMBERS WILL APPEAR IN DISPLAY

62
MEASUREMENT OF SENSOR
  • THEY CAN BE INTERPRETED AS FOLLOWS
  • 0000-0025 NORMAL
  • 0025-0030 LIMITED LIFE
  • 0030-UP REPLACE

63
MEASUREMENT OF SENSOR
  • THEY CAN BE INTERPRETED AS FOLLOWS
  • 0000-0025 NORMAL
  • 0025-0030 LIMITED LIFE
  • 0030-UP REPLACE
  • EVERY TIME THE SENSOR PLUG IS REMOVED, THE
    INFORMATION WILL BE LOST

64
MEASUREMENT OF SENSOR
  • THEY CAN BE INTERPRETED AS FOLLOWS
  • 0000-0025 NORMAL
  • 0025-0030 LIMITED LIFE
  • 0030-UP REPLACE
  • EVERY TIME THE SENSOR PLUG IS REMOVED, THE
    INFORMATION WILL BE LOST
  • MALFUNCTION OF SENSOR
  • WHEN A NEW SENSOR IS INSERTED PRESS SENSOR LIFE
    BUTTON.
  • IF 100 DOES NOT APPEAR, DO NOT USE SENSOR (SEE
    MANUAL)

65
COLTRI SUB
  • OPERATION

66
OPERATINGPROCEDURES
  • THIS PROCEDURE ASSUMES YOU HAVE ALREADY READ THE
    OPERATIONS MANUAL SUPPLIED WITH THE OXYTRONIC 600
    AND ARE A CERTIFIED GAS BLENDER

67
OPERATINGPROCEDURES
  • START YOUR COMPRESSOR IN THE NORMAL MANNER AND IF
    COLD ALLOW TO RUN WITH CONDENSATE DISCHARGES OPEN
    FOR 5-7 MINUTES
  • CLOSE THE MECHANICAL GAS VALVE AND LEAVE
    OXYTRONIC 600 TURNED OFF

68
OPERATINGPROCEDURES
  • SETTING INTERMEDIATE PRESSURE
  • ROTATE THE INTERMEDIATE GAS REGULATOR
    ANTI-CLOCKWISE UNTIL NO RESISTANCE IS FELT

GAS REGULATOR
69
OPERATINGPROCEDURES
  • SETTING INTERMEDIATE PRESSURE
  • ROTATE THE INTERMEDIATE GAS REGULATOR
    ANTI-CLOCKWISE UNTIL NO RESISTANCE IS FELT
  • OPEN O2 TANK VALVE UNTIL GAUGE ON RIGHT READS
    REMAINING GAS IN O2 TANK

O2 PRESSURE
70
OPERATINGPROCEDURES
  • SETTING INTERMEDIATE PRESSURE
  • ROTATE THE INTERMEDIATE GAS REGULATOR
    ANTI-CLOCKWISE UNTIL NO RESISTANCE IS FELT
  • OPEN O2 TANK VALVE UNTIL GAUGE ON RIGHT READS
    REMAINING GAS IN O2 TANK
  • SLOWLY ROTATE INTERMEDIATE GAS REGULATOR
    CLOCKWISE UNTIL INTERMEDIATE PRESSURE GAS GAUGE
    READS 5 BAR

5 BAR
71
OPERATINGPROCEDURES
  • IMPORTANT
  • WHEN THE PRESSURE IN THE O2 TANK DECREASES, THE
    READING ON THE INTERMEDIATE PRESSURE GAUGE WILL
    INCREASE.
  • THIS INCREASE OF INTERMEDIATE PRESSURE WILL
    CONTINUE AS THE O2 TANK EMPTIES

72
OPERATINGPROCEDURES
  • IMPORTANT
  • THIS INCREASE IN INTERMEDIATE PRESSURE WHICH IN
    TURN RESULTS IN HIGHER O2 IN THE BLEND
  • CAN BE COMBATED BY ADJUSTING THE O2 REGULATOR

O2 REGULATOR
73
OPERATINGPROCEDURES
  • TURNING ON OXYTRONIC 600
  • TURN ON KEY SWITCH

TURN ON
74
OPERATINGPROCEDURES
  • TURNING ON OXYTRONIC 600
  • TURN ON KEY SWITCH
  • PRESS ON BUTTON

PRESS ON
75
OPERATINGPROCEDURES
  • TURNING ON OXYTRONIC 600
  • TURN ON KEY SWITCH
  • PRESS ON BUTTON
  • THE RED AND GREEN LED WILL ILLUMINATE
  • THE GREEN LED WILL GO OUT BECAUSE AIR IS FLOWING
    THROUGH THE SYSTEM DUE TO THE COMPRESSOR RUNNING
  • DISPLAY WILL SHOW O2 APPROXIMATELY 20.9

76
OPERATINGPROCEDURES
  • TURNING ON OXYTRONIC 600
  • TURN ON KEY SWITCH
  • PRESS ON BUTTON
  • THE RED AND GREEN LED WILL ILLUMINATE
  • THE GREEN LED WILL GO OUT BECAUSE AIR IS FLOWING
    THROUGH THE SYSTEM DUE TO THE COMPRESSOR RUNNING
  • DISPLAY WILL SHOW O2 APPROXIMATELY 20.9
  • PRESS AND HOLD CALIBRATE BUTTON FOR 15 SECONDS TO
    CALIBRATE SENSOR TO AIR

CALIBRATE
77
OPERATINGPROCEDURES
  • TURNING ON OXYTRONIC 600
  • TURN ON KEY SWITCH
  • PRESS ON BUTTON
  • THE RED AND GREEN LED WILL ILLUMINATE
  • THE GREEN LED WILL GO OUT BECAUSE AIR IS FLOWING
    THROUGH THE SYSTEM DUE TO THE COMPRESSOR RUNNING
  • DISPLAY WILL SHOW O2 APPROXIMATELY 20.9
  • PRESS AND HOLD CALIBRATE BUTTON FOR 15 SECONDS TO
    CALIBRATE SENSOR TO AIR
  • OPEN MECHANICAL GAS VALVE

OPEN
78
OPERATINGPROCEDURES
  • SLOWLY TURN OXYGEN FLOW REGULATOR ANTI-CLOCKWISE
    UNTIL O2 INCREASES TO DESIRED BLEND PERCENTAGE

O2 REGULATOR
79
OPERATINGPROCEDURES
  • SLOWLY TURN OXYGEN FLOW REGULATOR ANTI-CLOCKWISE
    UNTIL O2 INCREASES TO DESIRED BLEND PERCENTAGE
  • PRESS AND HOLD IMPOST/ALARM BUTTON FOR 15 SECONDS
    UNTIL RANGE ALARM IS SET

IMPOST
80
OPERATINGPROCEDURES
  • SLOWLY TURN OXYGEN FLOW REGULATOR ANTI-CLOCKWISE
    UNTIL O2 INCREASES TO DESIRED BLEND PERCENTAGE
  • PRESS AND HOLD IMPOST/ALARM BUTTON FOR 15 SECONDS
    UNTIL RANGE ALARM IS SET
  • THE RED LED WILL GO OUT

81
OPERATINGPROCEDURES
  • SLOWLY TURN OXYGEN FLOW REGULATOR ANTI-CLOCKWISE
    UNTIL O2 INCREASES TO DESIRED BLEND PERCENTAGE
  • PRESS AND HOLD IMPOST/ALARM BUTTON FOR 15 SECONDS
    UNTIL RANGE ALARM IS SET
  • THE RED LED WILL GO OUT
  • IF YOU NEED TO CHANGE THE PERCENTAGE DURING THE
    BLEND, THEN YOU WILL NEED TO RESET THE RANGE
    ALARM TOO

82
OPERATINGPROCEDURES
  • ALLOW THE MIX TO RUN THROUGH THE SYSTEM FOR AT
    LEAST 2 MINUTES BEFORE OPENING FILL COCKS ON THE
    TANKS.

83
OPERATINGPROCEDURES
  • TURNING OFF OXYTRONIC 600
  • ONCE ALL TANKS ARE COMPLETED, THE USER MUST
    FOLLOW THESE STEPS IN ORDER

84
OPERATINGPROCEDURES
  • TURNING OFF OXYTRONIC 600
  • ONCE ALL TANKS ARE COMPLETED, THE USER MUST
    FOLLOW THESE STEPS IN ORDER
  • CLOSE TANK VALVES AND FILL COCKS

85
OPERATINGPROCEDURES
  • TURNING OFF OXYTRONIC 600
  • ONCE ALL TANKS ARE COMPLETED, THE USER MUST
    FOLLOW THESE STEPS IN ORDER
  • CLOSE TANK VALVES AND FILL COCKS
  • CLOSE O2 TANK VALVE AND ALLOW ALL O2 TO DRAIN
    FROM COMPRESSOR FOR AT LEAST 2 MINUTES

86
OPERATINGPROCEDURES
  • TURNING OFF OXYTRONIC 600
  • ONCE ALL TANKS ARE COMPLETED, THE USER MUST
    FOLLOW THESE STEPS IN ORDER
  • CLOSE TANK VALVES AND FILL COCKS
  • CLOSE O2 TANK VALVE AND ALLOW ALL O2 TO DRAIN
    FROM COMPRESSOR FOR AT LEAST 2 MINUTES
  • SWITCH OFF OXYTRONIC 600 AND COMPRESSOR

IMPOST
87
OPERATINGPROCEDURES
  • NOTE
  • IF A POWER FAILURE OCCURS, THE COMPRESSOR MUST BE
    RESTARTED BEFORE THE O2 CAN BE BLED FROM THE
    SYSTEM DUE TO THE NO FLOW SAFETY SYSTEM

88
OPERATINGPROCEDURES
  • ANOMALIES IN GAS BLENDING
  • DUE TO RELATIVE HUMIDITY, THE ACTUAL ATMOSPHERIC
    O2 PERCENTAGE MAY NOT BE 20.9
  • PLEASE REFER TO COMPENSATION CHART IN
    INSTRUCTION MANUAL FOR MORE INFORMATION

89
OPERATINGPROCEDURES
  • ANOMALIES IN GAS BLENDING
  • DUE TO THE MECHANICAL AFFECT OF THE COMPRESSOR
    COMPRESSING GASES, THE OUTPUT O2 WILL BE
    DIFFERENT FROM THE INPUT O2 (BY AS MUCH AS A FEW
    ). TO COMBAT THIS A SECOND IN-LINE O2 SENSOR CAN
    BE INSTALLED ON YOUR FILLING PANEL OR COMPRESSOR.
    THIS WILL ALLOW FOR A MORE ACCURATE BLENDS

90
COLTRI SUB
  • SOFTWARE

91
BLENDINGSOFTWARE
  • THE OXYTRONIC 600 COMES SUPPLIED WITH AN EASY TO
    USE EXCEL FORMAT BLENDING CALCULATOR
  • PLEASE LOOK AT THE FILE CALLED NITROX SOFTWARE.xls

92
BLENDINGSOFTWARE
  • LINE 1 CONTAINS INFORMATION REGARDING THE
    REMAINING GASES IN THE TANK
  • LINE 2 CONTAINS INFORMATION REGARDING THE DESIRED
    FILL OF THE TANK
  • LINE 4 HAS THE ANSWERS TO OUR CALCULATIONS
  • IF YOU STARTING FROM SCRATCH WITH AN EMPTY TANK,
    THEN PLEASE ENSURE THAT LINE 1 IS EMPTY

93
BLENDINGSOFTWARE
  • THIS EXAMPLE ASSUMES THAT YOU ARE BLENDING A TANK
    WHICH HAS REMAINING GAS IN IT
  • LINE 1- THE TANK HAS 100BAR OF NITROX 32
    REMAINING
  • LINE 2- YOU REQUIRE 220BAR OF NITROX 36
  • LINE 4- YOU ARE REQUIRED TO FILL AT NITROX 39 TO
    ACHIEVE YOUR BLEND
  • YOU MAY ALSO ENTER THE SIZE OF THE TANK IN LINE 3
    DEPENDING ON YOUR NEEDS

94
COLTRI SUB
  • This PowerPoint presentation, remains the
    property of
  • AEROTECNICA COLTRI S.P.A
  • Via Rio Ponale, 9
  • 25010 Rivoltella di Desenza del Garda
  • (BRESCIA)
  • Tel.0309910297 Fax 0309910263
  • Part.IVA 00648210987
  • e-mail coltrisub_at_coltrisub.it internet
    www.coltrisub.it
  • It is prohibited to copy this presentation even
    partially.
  • COLTRISUB has the right to modify this
    presentation
  • without notification to customers.
Write a Comment
User Comments (0)
About PowerShow.com