Title: Emcore vs. Agilent RX modules


1
Emcore vs. Agilent RX modules
Dirk Wiedner, Physikalisches Institut der
Universität Heidelberg
2
Optical receivers choice
3
What is the choice based on?
  • Transmission reliability
  • Optical data transmission must not degrade
    operation
  • Bit Error Rate of lt10-15 baseline
  • Single bit errors must not lead to global resets
  • Confirmation of promised performance in LHCb test
  • Compatibility Rx-Module must fit on O-RxCard
  • Availability Rx-Modules lead time, product
    lifetime
  • Price Competitive price ie. 400US (500 pc.
    needed)

4
Optical Properties
  • Input sensitivity of new Emcore MRX9515 5dB less
  • Agilent HFBR-782B or Emcore MRX9512 ok.
  • Fiber Length
  • 13m Breakout 25m 120m 1m typical

5
LHCb Tests (1/2)
  • Muon Trigger
  • numerous tests with Agilent HFBR 782B
  • RICH
  • detailed tests with Emcore MRX9512
  • ST / OT
  • tests with both

GOL VCSEL Emcore MRX9512
6
LHCb Tests (2/2)
  • Final qualification procedure (suggestion)
  • BERT with
  • LHCb GOL-VCSEL or 12-way Transmitter _at_1.6 Gbps
  • 15m breakout30m patch cord120m1m patch cord
  • extra 6dB attenuation
  • maximum BER 10-12
  • Repeat test for 10 receiver samples
  • Possibly ORCTest card opt. attenuator useful

7
Compatibility
  • most 12-way optical receivers close to SNAP12
  • O-RxCard IF14-1 can be configured for most
    receivers with jumpers
  • Electrical characteristics effectively equal
  • VCSEL diode or transmitter
  • output -2dBm max. (fiber loss 0.3 dB
    /interconnection)
  • obtain maximum optical power range
  • 125/50 µm MM 12-way ribbon fibers MTP/MPO

8
Availability
  • Agilent HFBR782B was available lately
  • Emcore MRX9512 bought last year
  • Emcore MRX9515 unacceptable as replacement
  • product policy unclear
  • Other competitors
  • Picolight
  • Zarlink

9
Price
  • up to 500 receivers necessary
  • all spares must be ordered now
  • 310 Euro ea. for 180 Agilent HFBR 782 (Muon
    trigger)
  • 400 US ea. for 38 Emcore MRX9512 (O-RxCard PP)
  • exchange rate 400 US 328 Euro 502 CHF

10
Summary
  • Two major candidates
  • Emcore MRX9512
  • Agilent HFBR782
  • Decision must be based on
  • appropriate specification (enough dynamic range)
  • Tests in LHCb scenario
  • solid product policy and availability
  • price must be competitive
Write a Comment