Comfort II - PowerPoint PPT Presentation

1 / 17
About This Presentation
Title:

Comfort II

Description:

Consists of CPU Board and DSP Board, joined by a 28 way connector ... on RS485 bus will remain compatible (Slaves, RIOS, Keypads, Door Stations, UCMs) ... – PowerPoint PPT presentation

Number of Views:49
Avg rating:3.0/5.0
Slides: 18
Provided by: Chiu7
Category:
Tags: comfort | rios

less

Transcript and Presenter's Notes

Title: Comfort II


1
Comfort II
  • Whats New (updated Jan 2008)

2
Two-Piece Design
  • Consists of CPU Board and DSP Board, joined by a
    28 way connector
  • CPU Board has Inputs, Outputs, Siren, Strobe,
    KA/KB, 12V etc for Alarm functions
  • DSP Board has Tel In, Tel Out, Voice, Mic, power
    supply for Voice and Dialing functions

3
Slave
  • New Generation Slave will be the CPU Board with
    Slave firmware
  • Power Supply board will replace the DSP board
    connected to the Slave

4
Flash Upgrades
  • Flash Firmware upgrade is available as Plug-in
    Module (MPU01)
  • Comfort II with Flash MPU plug-in (see picture)
    can be upgraded by firmware download via
    Comfigurator 2.2.x. This requires new UCM05
  • In 2008, Comfort II PCB will come with built-in
    Flash firmware and will not require MPU01

5
UCM05
  • New UCM05 is able to download new firmware
    upgrades to Comfort II with built-in Flash or
    Flash MPU. Requires Comfigurator 2.2.x
  • Programming Cable connects UCM05 with Comfort II,
    Slave II or UCM05/EIB/CBUS to be upgraded
  • IR Learning is standard feature

6
Local Expansion Modules
  • LEM01-M2 or LEM02-M2 or LEM03-M2 will plug on top
    of CPU or Slave Board
  • Output module will be plugged into LEM and can be
    removed

7
Battery Protection
  • Battery protection function is built in. BPM01
    Module not required.
  • Prevents over-discharge of battery
  • Current limits charging current to a low battery

8
Piggyback Modules
  • Ringer Module RGR04 can be plugged in
  • LEM can be plugged in
  • Output Module can be plugged in. This allows
    damaged Outputs to be replaced without any
    downtime
  • Firmware upgrades can be plugged in
  • Saves space in the enclosure

9
Isolation
  • Comfort circuitry is isolated from earth. Plastic
    standoffs for mounting PCB
  • Provides better protection from lighting induced
    surges.
  • All Inputs and Outputs have been tested to 4kV
    surge.
  • Improved Telephone line protection

10
Testing/Approvals
  • EMC compatibility for US and European standards
  • Safety testing for CE Mark
  • PSTN standards compliance to US, European and
    Australian standards
  • Tested to extended surge voltages (4 KV) compared
    to European standards

11
Full Duplex Intercom
  • Full Duplex Intercom between Tel and KP/DP and
    between KP and DP
  • New KP04 versions needed with better acoustic
    isolation
  • KP03 and DP03 replaces KP01/02 and DP01
  • DP and KP have separate Mic/Voice connections

12
Various Improvements
  • Better Busy Tone detection during recording,
    voice menu, Intercom
  • Automatic Gain Control (AGC) during recording

13
Vocabulary Tool
  • VoiceProc software allows customisation of
    wordlists for specific applications and
    development of vocabularies in other languages
  • VoicePlay allows sentences to be heard in
    compressed and original form

14
System Voltage
  • CPU and DSP circuitry operates at 3V instead of
    5V.
  • This means analog input voltage is 0 to 3V

15
Other New Features
  • Conditional Branch Instructions will improve
    if/Then code generation
  • 32 Time Programs
  • 16 Reminder Messages
  • Say Word Action
  • 64 User Timers

16
Compatibility
  • All current external modules on RS485 bus will
    remain compatible (Slaves, RIOS, Keypads, Door
    Stations, UCMs)
  • KP01, KP02, KP04, DP01 will remain compatible but
    with poor performance for full duplex intercom.
    Upgrade to KP03, KP04/X, DP03 is recommended

17
Comfort I v Comfort II
  • Comfort I Ultra
  • 8 reminders
  • 16 time programs
  • 16 User timers
  • One-way intercom ½ duplex between KP and DP
  • File System 24
  • Firmware upgrade via change of U1 IC
  • Comfort II Ultra
  • 16 reminders
  • 32 time programs
  • 64 User timers
  • Two-way intercom full duplex between KP and DP
  • File System 34
  • Firmware upgrade via download to MPU01 or Flash
    firmware