Title: Pelletrons 2002 2004
1Pelletrons2002 - 2004
3 MV Electron with capacitor bank Hypersonic wind
tunnel National Lab 3 MV tandem AMS (general
purpose) Actinide ratio isotope
ratios University 1.7 MV tandem with microprobe
(RBS) Material analysis College (undergrad) 1.2
MV tandem with Oxygen isotope ratios University
customer supplied SIMS injector NASA Genesis
project 3.5 MV tandem with Fast Pulsed Neutron
Private Company Pulsed/bunched TORVIS
injector Analysis (PFNA) Compact AMS
(carbon) Archeology University Compact AMS
(carbon) Archeology Private Company Compact AMS
(carbon) Biomedical Private Company Compact AMS
(carbon) Biomedical Private Company Compact
AMS Earth Sciences National Lab
(carbon-partial system) Single Stage AMS (carbon)
Archeology/biomedical University Single Stage
AMS (carbon) Pharmaceutical Private
Company Single Stage AMS (carbon) Pharmaceutical
Private Company
2Sandia National Lab1.5A pulsed
electronsHypersonic Wind Tunnel
22kJ
3Sandia
4Seconda Universita degli Studi di Napoli9SDH-2
AMS
5NaplesAMS thru the Actinides
6NaplesAMS thru the Actinides
7Hope College5SDH1.7 MV tandem Pelletron
8Hope College10-20 micron 3 MeV He
9Genesis Project
10UCLA (Genesis)Multi Faraday cup chamber
11Pulsed Fast Neutron Analysis
12Nanosecond pulsing and bunching
13Accelerator Mass Spectrometry
2002-2004 9 New Systems Mostly Carbon
14/12 Measurements now back to 75,000 years
(sample limited)
TOTAL 21 dedicated systems (Another 15 doing
AMS for some of the available beam time) 44
Sources sold for AMS (40 MC-SNICS and 134
MC-SNICS)
14Background 14C
2 out of 1016 is like sorting out 2 grains of
sand (0.5mm) from a beach
1 meter deep by 100 meters wide by 12.5
kilometers (7.76 miles) long
15LLNLThe CAMS Facility
16(No Transcript)
17Radiocarbon Lab GeoBiosphere CentreLund, Sweden
18LLNL
Biomedical AMS14C tracing
Stay away from grilled chicken Always marinate
your steak Avoid Tylenol Eat the greenest
vegetables you can find With lots of caffeine!
19NEC Sub-Systems2002 - 2004
Pelletron Charging Western Michigan University
EN Conversion Pelletron Charging University of
Köln FN Conversion
7 MPs converted 11 FNs converted 6 ENs
converted
High Current He-/H- Ruhr-Universitat Bochum
TORVIS injector Dynamitron Tandem Lab 15 keV
Negative University of Illinois at
Urbana-Champaign Heavy Ion System Center for
Microanalysis of Materials 250 kV deck Oak
Ridge National Laboratory 7.3m x
3.6m (HRIBF) To support 27,220 kg High
Power Target Laboratory
20TORVIS Injector300-500 H-12-20 µA He-
21High Current He- Injector
2215 keV Negative Ion SystemCenter for
Microanalysis of MaterialsUniversity of Illinois
at Urbana-Champaign
23250kV Source DeckHigh Power Target
LaboratoryHRIBF/ORNL