Title: Implementation of Energy efficiency labelling in China
1Implementation of Energy efficiency labelling in
China Jin Minghong China National Institute
of Standardization (CNIS) 2006-2-10
2Products covered
- Household refrigerators and room air conditioners
were covered by the mandatory label system on
March, 1st , 2005 - household refrigerators
- electric motor driven compressive type
refrigerators with volume of 500L and below. - Room air conditioners
- air conditioners using air cooling condenser,
closed motor-compressor, with cooling capacity
under 14000W, working under climate T1. - Not applicable to speed-variable, mobile and
multi-connected air-condition (heat-pump) unit.
3Criterion of energy efficiency classification
- Energy efficiency national standards
- household refrigerators
- GB12021.2 -2003
- The maximum allowable values of the energy
consumption and energy efficiency grades for
household refrigerators - Room air conditioners
- GB12021.3 -2004
- The minimum allowable values of the energy and
energy efficiency grades for room air conditioners
4Energy efficiency standards in China
- E-E standards covered 21 products
- --householder appliances 8
- --lighting product 6
- --commercials equipment 2
- --industrial equipment 4
- --car passenger car
5The list of energy efficiency national standard
China research center of Car. energy
efficiency classification, Evaluating value
for energy conservation certification.
6The list of e-e national standard (continued)
China research center of Car. energy
efficiency classification, Evaluating value
for energy conservation certification.
7Methodology of developing energy efficiency grades
- 1?statistics analyses of e-e of products in
market - 2 Engineering economic analysis
- Life cycle cost
- Macro analysis for standards impacts to nation,
manufactures,consumers - economic effects
- energy saving potential
- pollution mitigation
8LCC Model for air conditioners
9LCC Model for air conditioners
10Principals of setting E-E grades
1 grade international level, the top 510 of
market share in term of energy efficiency 2
grade the lowest LCC, the top 20 of market
share, meets the evaluating value of energy
conservation ( a voluntary label) 3
grade average level of energy efficiency in
market 4 grade below average level 5grade
to be removed in 24 years. The lowest 10 of
products in e-e
11Categorical criterion of air conditioners and
refrigerators
12Comparison of EE of air conditioners between EU
and China
13Comparison of EE of refrigerators between EU
and China
14Pattern of China Energy Label
15Specifications of label design of refrigerators
Manufacturer name
Product model
E E grade
Electricity consumption per day
Volume of different cabinets
Standard code
16specifications of label design of room air
conditioners
Manufacturer name
Product model
E E grade
E E ratio
Power input
Cooling capacity
Standard code
17 Implementation procedure
1 determining label's information against
Energy Efficiency National Standards2 whether
label's information is correct or not? 3
whether the pattern of the label used is
compliance or not? 4 whether the label used was
registered to CNIS or not? 5 whether register
material is correct integrated or not? 6
whether the label information need be revised or
not? T True F False
18Register procedure
???????? Enterprises submit their registration
information
???????? The use of energy labels
???? Documentation and checking
???manufactures
???? Authorized institution
???????????? Notification at energy label website
??????? Record number
????? Inform registers
?????? Government monitoring
??????????? The public inquire the notification
and relevant information
19Requirements of Energy efficiencys test report.
- manufactures testing their products energy
efficiency in themselves lab is permitted - To Use unified template of testing report.
- When dispute occurs over an energy-efficiency
value, it shall be retested by a lawfully
recognized or an officially accredited
third-party testing laboratory for arbitration.
20How to identify information of the
label-refrigerators
- the EE grade should accord to GB12021.2 and
test report - The labeled electricity consumption should be
lower than 1/1.15 of tested consumption and
lower than the max. value against the labeled EE
grade. - The each cabinets volume tested should be not
lower than 97 of labeled volume.
21How to identify information of the labelAC
- the EE grade should accord to GB12021.3 and
test report - The labeled EE ratio should be lower than lower
than the max. value against the labeled EE
grade. - Tested Power input for cooling should be lower
than 110 of the labeled value. - The cooling capacity tested should be not lower
than 95 of labeled value.
22Register procedure of Energy efficiency label.
- the products shall be registered within 30 days
after it has been labeled. The following
documents shall be provided to CNIS, the
authorized body - 1. Copy of the business license or the
testimonial of their registration for
manufacturers copy of the relevant contract with
the producers overseas for importers - 2. Test report of the product energy efficiency
- 3. Sample of the label
- 4. Other relevant information, such as the
initial date to apply the label - 5. In the case that an agent submits, on behalf
of the manufacturer or the importer, documents
for the registration, a proxy document of the
client shall be presented. - A Chinese version shall be submitted along with
the documents originally written in foreign
language, and the former is given preference.
23www.energylabel.gov.cn
24Bulletin system for the label
25Present status of the labels implementation
Up to Nov. 2005, near 4000 models of air
conditioners covered more than 60 manufacturers,
and near 2200 models of refrigerators covered
more than 70 manufactures were registered. More
than 98 of refrigerators and air conditioners
was attached the label in Chinese markets. The
label program runs smoothly in China.
26(No Transcript)
27Energy efficiency distribution of refrigerators
and room air conditioners in Chinese market
Model distribution
from March, to Nov. 2005
28Energy saving potential from the label
- If the label covers 8 products including some key
household appliances and lighting products in
China - -up to 2010, the label system will save
about 70 billion Wh. - -up to 2020, the label system will save about
250 billion Wh.
29Please contact me
- Jin Minghong
- China National Institute of Standardization
- Sub-institute of resource and Environment
standardization - AddressNo.4 Zhichun Road, Beijing
- Post code 100088
- Tel86-10-58811718
- FAX86-10-58811714
- E-mail Jinmh_at_cnis.gov.cn
- http//www.energylabel.gov.cn
30Thank you very much!