Scheme 6 Antibody Detection - PowerPoint PPT Presentation

1 / 10
About This Presentation
Title:

Scheme 6 Antibody Detection

Description:

ELISA Quikscreen/ B-Screen = 7. LATM = 5. Biotest = 1. Luminex LabScreen = 26. Lifecodes = 3 ... CDC ELISA. 2nd Cycle. 1st Cycle. Technique. Hidden Negatives ... – PowerPoint PPT presentation

Number of Views:99
Avg rating:3.0/5.0
Slides: 11
Provided by: jude6
Category:

less

Transcript and Presenter's Notes

Title: Scheme 6 Antibody Detection


1
Scheme 6Antibody Detection
2
Scheme Summary
  • 2 send outs of 10 samples
  • Report results within 8 weeks
  • 2008 43 participants
  • 75 concordance between labs
  • Two assessment cycles
  • Penalty scoring system

3
Methodology 2008
ELISA Quikscreen/ B-Screen 7 LATM
5 Biotest 1
Luminex LabScreen 26 Lifecodes 3 Both
3
4
Methodology 2008
5
Methodology 2008
6
Hidden Negatives
  • 8 AB sera
  • Total number of results 340
  • Number of false positives 55 (16.1)
  • 5 CDC
  • 50 LS
  • 10 labs reported false positives

7
Sera Distributed in 2008
8
Penalty Point Scoring System for 2008
Penalty Score Each report in agreement
with the consensus 0 Each report not in
agreement with the consensus 4 Each report of an
equivocal result 1 Poor Performer gt8
penalty points in any one cycle Persistent Poor
Performer PP in any two consecutive cycles
9
Penalty Points for 2008
  • 1st Cycle
  • 0 penalty points 29 labs
  • 4 penalty points 3 labs
  • 5 penalty points 1 lab
  • 8 penalty points 3 labs
  • 12 penalty points 1 lab
  • 16 penalty points 5 labs
  • 2nd Cycle
  • 0 penalty points 33 labs
  • 4 penalty points 2 labs
  • 8 penalty points 3 labs
  • 12 penalty points 1 lab
  • 16 penalty points 4 labs
  • 2 PPP in 2008

10
Labs in the PP Category