Decision 30 - Maintenance Unit Length
  • Options
  • Half the distance between refrigerators 3km
    sector
  • 0.5km units (requires 6 U-tubes or 24 valves
    at each location)
  • BCD 3Km sector
  • Pro
  • Minimizes the component count
  • Minimizes the heat load.
  • Con (500m units provide)
  • Reduced thermal cycles on CMs. (factor 5)
  • Reduced warm up times (factor gt2)
  • Reduced cooldown times (factor 10)
  • Reduced He storage (factor 5)
  • Refrigeration load sharing
  • Modular upgrade elements
  • ACD If the component reliability can not be
    reached change design to 500m maintenance units.

2
Decision 38 - Refrigerator Spacing
  • Drivers T. Petersons presentation 5km
  • 2K temperature (pressure), Gradient, Q, cavity
    shape 300 mm pipe diameter determine the
    maximum length of the pumping line.
  • Maximum coldbox size 25kW of 4.5 K equivalent
  • Options
  • Pair of refrigerators at common locations each
    feeding a 3.5km sector (Pipe limited)
  • Single larger refrigerator each feeding two
    2.8km sectors (Refr limited)
  • BCD Single refrigerator spaced 5.6km
  • Pro
  • Option B minimizes the pressure drops in the CM
  • This reduces the baseline warm-up unit length.
  • Con
  • The TESLA design used option A it permitted an
    initial half refrigeration installation
  • Increases the number of utility systems required
    Purifiers, LN2 systems, LHe systems, GHe systems,
    ICW, etc
  • Required task After the Decisions 3, 10 25
    etc are chosen the 5.6Km needs to be verified