Reduce noise exposure!!!
  • S.C NUTRICOM S.A OLTENITA
  • How to reduce phonic poluttion at workplaces
  • Work Protection Departement
  • Ing. Paun Gilio-Nicolae

2
Reduce noise exposure!!!
  • S.C NUTRICOM S.A OLTENITA was found as a
    productive unit of concentraded forages in year
    1964. After 1990 is ghange into a company and in
    1995 became joind-stock company,today she have
    entirely joind-stock capital
  • Because of massive capital investments mayde
    after she became joind-stock company,todaz she is
    a match more known name on the marchet of
    garden stuff.Concentreded forages factory is
    making food for animals from different farm, but
    also for personal farms were we breed pigs in
    Sohatu, Chirnogi, Manastirea,Dragalina and farms
    were we breed birds Dragalina, S.C. Avicola
    Calarasi.

3
Reduce noise exposure!!!
  • Flow sheet unfolded to produce concentraded
    forages is
  •     Purveyance and reception of raw materials
  • Ø    Storage raw materials
  • Ø    Weighing,measuring each component wich is
    used into job mix formula
  • Ø    Grind macrodimensional components
  • Ø    Mixing-for final product homogenization
  • Ø    Graining forages with steam help
  • Ø    Storaged final product(concentaded forages)
    warck or into a sack

4
Reduce noise exposure!!!
  • Flow sheet is taking place with help from next
    devices
  • Ø     Beltcarrier and elevating belt of raw
    materials
  • Ø     3 electronic weighing equipaments and 2
    bonded strain gange
  • Ø     2 automatica tare unit-bug for cereales
    and final product
  • Ø     1 raw materials blender-4 t capacity
  • Ø     2 mills to grind raw materials of 40t/h
    capacity
  • Ø     3 graining machines -30t/h capacity
  • Ø     3 coolers and 3 cruching mills
  • Ø     tehnological water installations,vegetable
    oil, compressed air,steam
  • Ø     control unit from were the flow sheet is
    supervised by a computer and automated.

5
Reduce noise exposure!!!
  • Maximum design capacity of forages factory
    production is 40 t/h concentraded forages.
  • Annual output was in 2004 of 67.000 tone
  • Production tehnology was provided by a dutch
    company VAN AARESEN, and is being used sinse
    1997,with a contract which contain studies,
    production tehnology design and complet delivery
    of the line production,having all the equipament
    to the europen standars in that year.
  • Those were certicated regarding tehnical quality,
    but also reguarding requirements of heath and
    safety at work.

6
Reduce noise exposure!!!
  • Noise is a risk factor which can lead to hearing
    disabilitites and match more negative effects
  • harm to internal ear
  • increased risk of workplace accidents
  • work related stress
  • Going from this premises,the management of S.C
    NUTRICOM S.A OLTENITA and Work protection
    department allway thought that noise at workplace
    can not be neglected.
  • Knowing the fact that machines used in the flow
    sheet generate noise ,S.C NUTRICOM S.A OLTENITA
    is allways taken action to reduce this risk
    factor.

7
Reduce noise exposure!!!
  • Noise problem was approached into the next
    directions
  • 1. Assessing the risks linked to
    noise,this thing is made with competent persons
    from Work protection department,under straight
    guidance of I.T.M Calarasi inspectors
  • 2. Eliminate noise sources,there were this
    thing is possibile
  • 3. Combating noise by adopting prevention
    policy and limited exposure
  • 4. Reviewing and checking workplaces- to
    establish possible changes

8
Reduce noise exposure!!!
  • Assessing the noise
  • Is made by the peoples from Work Protection
    Department wich analyse workplaces exposed to
    noise ,noise sources,level,type and time exposure
    to noise of the employes.
  • Also is taking into account informations given by
    the technical equipament producers and
    informations received from medical examination.

9
Reduce noise exposure!!!
  • We found the workplaces wich are probable more
    expoused to noise as a professional insult
  •   Graining machines workplace occupied by
    maitenance electrician and engine attendant which
    is taken care of the graining machines.Exposure
    to noise is permanently during the 12h shift
  • Salt supply workplace occupied by an
    worker who supplyed with salt taking into
    account electrical measuring.Noise exposure is
    periodical,of approximated 6-7h/day during
    the 12h shift
  •  Mills and Classification mills- flow sheet
    components were are not workplaces,but were
    noise is high and affect other workplaces from
    inside and outside

10
Reduce noise exposure!!!
  • S.C NUTRICOM S.A OLTENITA allways maded
    measures to the level of noise with help from
    DSP Laboratory and under direct guidance of I.TM
    Calarasi inspectors.
  • Last recordings was made in this year 2005 and
    this are the values
  • Graining machines 99 dbA
  • Salt supply 94 dbA
  • Clasification mill 98 dbA
  • Mills 104 dbA

11
Reduce noise exposure!!!
  • Eliminate noise sources
  • S.C NUTRICOM S.A OLTENITA is preocuped to
    eliminate noise sources, there were this is
    possible.
  • Renewal found started with reversing line
    production in 1997 it meant not only adopting
    some modern solutions to made concentrateded
    forages,but also eliminate important noise
    sources, a lower consuming of energy,
    improvement work conditions.
  • Also in 2002,the management of S.C NUTRICOM S.A
    OLTENITA takes a decision to interrupt tow
    cereale dryers US-14,from grain elevator,machines
    which contained important noise sources.

12
Reduce noise exposure!!!
  • Combating noise
  • 1. Combating noise at source though tehnical
    measures
  • Avoiding impact metal on metal
  • Regulary monitor and review machines and
    equipament
  • Placing noise and vibration dampers(for example
    rubber bumper at mills)
  • Cheking all machises with sound absorbent
    cabines

13
Reduce noise exposure!!!
  • 2. Group measures to fight against noise
  • Access restriction near noisy areas(for example
    workes access restriction near mills and graining
    machines,were are allowed only workes nominated
    on establish schedule
  • Use for protection only materials soun
    absorbent, today in the building whith containd
    all the machines is put on panels type
    EcoPanel,type sandwich, having role to protect
    againt fire and sound isulation. This thing is
    made to reduce noise propagation outside and
    though other workplaces.
  • Organised work program, so that work in noisy
    area can be limited
  • Alternating workes at workplaces expouse to noise
  • Planning all activitys which is making noise so
    that can affect a small number of worker.

14
Reduce noise exposure!!!
  • 3. Individuals means of hearing protection
  • People who works at places were noise is a risk
    factor most have individual hearing protectors
    internal and external(headset)
  • Individual hearing protectors is necessary and
    obligatory
  • Workes have possibility to choose the type of
    individual hearing protector much cozy and they
    are teached to use them

15
Reduce noise exposure!!!
  • Workplaces reviewing submited to noise
  • S.C NUTRICOM S.A OLTENITA is taking into account
    all workplaces submited to noise under straight
    guidance of I.T.M Calarasi inspectors.
  • Periodical are made measures to the level of
    noise,and the last set of measures was made this
    year.
  • For future our society it want to act against
    noise, to diminish this profesional insult,
    especialy that the european standard will be at
    a level of 87 dbA

16
Reduce noise exposure!!!
  • Our measures to reduse noise in the future is
  • Use only sound-proof housing near noise sources
  • To build sound abrorbent cabines for our workers
  • More individual hearing protectors but also for
    vibrations
  • Program to hold under controll noise exposure
  • To acquire only equipament that are protected
    against noise

17
Reduce noise exposure!!!
  • Noise problem is more complex and from this
    point of view things are far from being good.
  • S.C NUTRICOM S.A OLTENITA have not register until
    today any illness realted to noise and will be
    carrying on
  • with the same attention to respect work
    legislation in
  • long-term of european integration
  • VA MULTUMESC !!!