General Scan for DoubleHypernucleus - PowerPoint PPT Presentation

1 / 20
About This Presentation
Title:

General Scan for DoubleHypernucleus

Description:

while Hybrid-Emulsion detects limited LLX. We try General Scan for search of LLX ... Discovery of m- by Eye-Scan of Emulsion. Golden Age of Particle Physics ... – PowerPoint PPT presentation

Number of Views:36
Avg rating:3.0/5.0
Slides: 21
Provided by: hayatam
Category:

less

Transcript and Presenter's Notes

Title: General Scan for DoubleHypernucleus


1
General Scan for Double-Hypernucleus
  • HAYATA, Masashi
  • Kyoto Univ.
  • 2006.9.22, JPS Meeting

2
Index
  • Double-hypernucleus Search
  • Algorithm of General Scan
  • Summary

3
Double-hypernucleus Search
  • Nucleus with S-2 (LLX, LSX, SSX, XX, HX)
  • Research for Nuclear Structure,
  • Hyperon-Hyperon Interaction, H-Dibaryon
  • Short Range Decay Particles gtgt Emulsion
  • Too Rare Event gtgt Hybrid-Emulsion (Limit by
    others)

4
Detectable Stopped X- by Hybrid-Emulsion
of E373_at_KEK
Detector Acceptance 50
p(K-,K)X-
p(K-,K)X- n(K-,K0)X- 2050
1.66GeV/c K-
Detection Efficiency 30
X- in Target 65
Detectable X- 25
N(K-,K0)XLL ??
5
Algorithm of General Scan
  • Try all possibility
  • Hough Transform (Nagoya Univ.)
  • Pattern Matching_at_Neural Network
  • (Tsunemi _at_ Kyoto Univ.)
  • Huge Calculation, Simple Operation
  • gtgt Hardware Easy, Effective SIMD Processing
  • Select hopefuls
  • Figure Parameter Cut (Hayata _at_ Kyoto Univ.)
  • Smaller Calculation, Complex Operation

6
Flowchart of General Scan
Grayscale Image
Convexity Cut
Sum and Binarize
Different Sum and Binarize
Convexity Cut
Vertex Identify
Eye Scan
Double hypernucleus
7
Binarize with Maximum Method
Normal Binarize
Grayscale
Local Maximum
Grayscale
Normal Binarize
Grayscale
Local Maximum
Relative Grayscale
Relative Binarize
Relative Binarize
Relative Grayscale
8
Figure Parameter Cut
  • Grayscale Image
  • Binarize Image
  • Area, Perimeter,
  • Figure Parameter Cut
  • Convexity S / Sh
  • Circle, Square, 1
  • Vertex-Like ltlt 1

Sh
S
S
Convexity 1
Convexity 0.55
9
Test of Figure Parameter Cut
  • This test is to Biased Samples
  • So I will test to more samples

10
Summary and To Do
  • General Scan can detect all LLX
  • while Hybrid-Emulsion detects limited LLX
  • We try General Scan for search of LLX
  • To-do for next JPS Meeting
  • Build up Sum-up Algorithm and Convexity Cut
  • More Statistics for Algorithm Study
  • Other To-do List
  • Build 2nd Cut Algorithm (Hough Transform?)
  • Estimate Efficiency (Compare to eye-scan?)
  • Improve Microscope System

11
Appendix
12
Double-hypernucleus Events
13
Cross section of K-p -gt KX-, K-n -gt K0X-
  • If I(1) double K exchange or S resonance only,
  • s1(K-n -gt K0X-) / s0(K-p -gt KX-) 4
  • If I(0) L resonance, K-p is enhanced
  • K-n-gtKX-, P1510, s1/22026

Phys. Rev. 147 p945
Phys. Rev. 179 p1262
14
Hough Transform for Line
  • r x cosq y sinq
  • Non Infinite and Uniform

r x cosq y sinq
0ltrlt(X2Y2)1/2, 0ltqltp
15
Evade Interlace and Binarize
  • Refer even/odd line only when Binarize
  • Binarize Method
  • Simple Threshold
  • Simple Mean
  • Gaussian Weighted Mean
  • Median
  • Minimum/Maximum

16
Light Adjust and Optimize Contrast
Shallow
Shallow
Deep
Deep
17
Convexity Plot
Vertex Like
18
Microscope System
  • Standard System
  • 100Hz CCD Camera
  • 25x25cm2 Emulsion
  • If x20 Lens and 5mm pitch for z
  • gtgt 7day/emulsion
  • Enable to analyze,
  • but want Fast CCD
  • and more Microscopes

19
History of Image Processing
20
Result of Figure Parameter Cut
Write a Comment
User Comments (0)
About PowerShow.com