EDM in ER2 at LANSCE - PowerPoint PPT Presentation

About This Presentation
Title:

EDM in ER2 at LANSCE

Description:

EDM in ER2 at LANSCE – PowerPoint PPT presentation

Number of Views:73
Avg rating:3.0/5.0
Slides: 15
Provided by: janb64
Learn more at: https://p25ext.lanl.gov
Category:
Tags: edm | lansce | bismuth | er2

less

Transcript and Presenter's Notes

Title: EDM in ER2 at LANSCE


1
EDM in ER2 at LANSCE
  • Jan Boissevain
  • LANSCE ER-2 Stake Holder Meeting 6-05-03

2
EDM EXPERIMENT ASSEMBLY
DR Gas Cart Control Rack
DR 3He Pump System DR 1K Pot Pump System
Purifier 1ºK Pot Pump System
Steel/Poly Shielding
3He Polarized Source
3He Polarized Source Backing Pump Gas System
Support Framework
Beam Guide Polarizer
Perm-alloy Magnetic Shielding (5 Layers)
T0 Chopper
EDM Cryostat
Cold Head Compressors
1000 Liter Dewar
Bismuth Filter
3
(No Transcript)
4
(No Transcript)
5
(No Transcript)
6
(No Transcript)
7
EDM in ER2 Requirements
  • Floor Space Issues
  • Access for Maintenance operations
  • Staging area w/ crane coverage for assembly
    activities
  • Access to Upper Cryostat
  • Initial Installation of large components mobile
    crane to move items over flight-path 13
  • Counting House floor space
  • Vibration Isolation Pad
  • Crane Path Access across FP12 and FP13

8
EDM in ER2 Requirements (2)
  • Service Issues
  • AC Power 250KVA (see list)
  • Possible 4He Liquefier/Compressor shed
  • Safety Issues
  • Emergency Helium Vent (exit out east wall)
  • Radiation Safety especially on top of apparatus
  • Crane Trip (highest point of current design 17)
  • NPDGamma Issues
  • EDM T0 Chopper located in Beam Stop
  • Bismuth Filter inside NPDGamma cave

9
(No Transcript)
10
EDM IN ER2 ELEVATION
11
EDM Experiment Power Requirements
  • DRS 3000 Dilution Refrigerator 32KW
  • 4He Purifier Pump 23KW
  • 3He Polarized Source 23KW
  • EDM Cryostat 33KW
  • Miscellaneous 39KW
  • Optional Liquefier 50KW
  • Spare Capacity 50KW
  • Total 250KW

12
EDM Experiment Power Requirements (2)
  • DRS 3000 Dilution Refrigerator
  • 3He Circulation/1K Pot Pump System
  • 4000 M3/hr Roots Pump 15KW
  • 1000 M3/hr Roots Pump (2) 6KW
  • 70 M3/hr Dry Backing Pump (2) 5KW
  • 3He Gas System Controls 6KW
  • 4He Purifier Pump System
  • 4000 M3/hr Roots Pump 15KW
  • 1000 M3/hr Roots Pump 3KW
  • 70 M3/hr Dry Backing Pump (2) 5KW

13
EDM Experiment Power Requirements (3)
  • 3He Polarized Source
  • RDK415D 4KCold Head 9KW
  • Varian V2000 Turbo Pump 2KW
  • Varian V1000 Turbo Pump (2) 3KW
  • Edwards XDS10 Scroll Pump (3) 3KW
  • Pfeiffer Unidry 050 Pump 4KW
  • Gas Cart Instrumentation 2KW
  • EDM Cryostat
  • RDK415D 4KCold Head (3) 27KW
  • Vacuum Pumps 6KW

14
EDM Experiment Power Requirements (4)
  • Miscellaneous
  • Leak Detector 2KW
  • HV Power Supply 2KW
  • Bismuth Neutron Filter Cold Head 15KW
  • EDM General Controls Data Acquisition
    10KW
  • T0 Chopper 10KW
Write a Comment
User Comments (0)
About PowerShow.com