Title: Aerogel Cherenkov counters for CBM
1Aerogel Cherenkov counters for CBM
- S.V.Afanasiev
- VBLHE JINR
- Dubna
GSI meeting 20-21 November 2003
Afanasiev S.V.
JINR Dubna
2The envisaged CBM physics program
- Signatures of chiral symmetry restoration.
Probes Dilepton pairs, D mesons. - The deconfinement phase transition. Probes
charmonium, strangeness, collective flow. - The critical point. Probes event-by-event
fluctuations (K/pi ratio) - Exotic states of matter. Probes strange and
multistrange particles, K/p ratio
GSI meeting 20-21 November 2003
Afanasiev S.V.
JINR Dubna
3AEROGEL PROPERTIES
- Silica aerogels are a colloidal form of glass.
They are solid, very light, transparent and
refraction index can be in range 1.1 - 1.002.
Ya.Wang and W.L.Wolf, J.Opt.Soc.Am., Vol.73,
No.11 (1983)
GSI meeting 20-21 November 2003
Afanasiev S.V.
JINR Dubna
4Silica aerogels of low refractive index
(n1.012-1.028) arefound to be radiation-hard at
least up to 9.8 Mrad of gamma ray radiation.
S.K.Sahu et al. NIM A382(1996)
GSI meeting 20-21 November 2003
Afanasiev S.V.
JINR Dubna
5KEDR aerogel system
- 160 counters
- 800 liters of aerogel
- refractive index n1.05
- p and K separation in the momentum range 0.6 -
1.5 GeV/c.
M.Yu.Barnykov et al., NIM. A 453(2000)
GSI meeting 20-21 November 2003
Afanasiev S.V.
JINR Dubna
6BELLE ACC
- 1188 counters
- 2000 litters of aerogel
- refractive index n1.03-1.01
- p and p separation in the momentum range up to
3.5 GeV/c.
T.Sumiyoshi et al. J.Non-Crys. Sol. 225(1998)369
GSI meeting 20-21 November 2003
Afanasiev S.V.
JINR Dubna
7PHENIX ACC
- 160 counters
- 420 liters of aerogel
- refractive index n1.012
- K and p separation in the momentum range 0.2 -
2.0 GeV/c.
M.Yu.Barnykov et al., NIM. A 453(2000)
GSI meeting 20-21 November 2003
Afanasiev S.V.
JINR Dubna
8GSI meeting 20-21 November 2003
Afanasiev S.V.
JINR Dubna
9The PHENIX ACC together with TOF can extend the
PID capability upto 10 GeV/c
GSI meeting 20-21 November 2003
Afanasiev S.V.
JINR Dubna
10JINR ACC test
Large TOF base for particle separation
Secondary particles p, p of the nuclotron beam
V.F.Peresedov et al. Proc. Of the RNP Int.
Workshop, Slovak Rep. Stara Lesna, 2003
GSI meeting 20-21 November 2003
Afanasiev S.V.
JINR Dubna
11Aerogel Signal for protons and pions
2 GeV/c
Pions
d
Proton
Protons
K
Pion
- Clear separation of protons and pions observed.
PID by TOF successful
GSI meeting 20-21 November 2003
Afanasiev S.V.
JINR Dubna
12Potentialities of ACC
To see the threshold momenta for the different
indices of AEROGEL, the expected number of
emitted photon are calculated through empirical
equation N p.e. 55 L 1-(1/nb2)
GSI meeting 20-21 November 2003
Afanasiev S.V.
JINR Dubna
13Particle density N/100 cm2 along the
horizontal axis (black line) and along
the vertical axis (red line) within 10 cm wide
windows which cross the center of the detector
GSI meeting 20-21 November 2003
Afanasiev S.V.
JINR Dubna
14Segmentation of Aerogel
Emission angle, charged particle density,
detector surface, pad size and number of cells
per aerogel layer. The numbers refer to a central
AuAu collision at 25 GeV/u and an occupancy
below 5.
GSI meeting 20-21 November 2003
Afanasiev S.V.
JINR Dubna
15Aerogel RICH
GSI meeting 20-21 November 2003
Afanasiev S.V.
JINR Dubna
16CONCLUSIONS
For study
- refractive index lt1.01
- physical and chemical properties
- refractive index 1.1 - 1.005
- radiation-hard
- stable
- compact size
The Aerogel Threshold Cherenkov detector can be
used as bridge between TOF and gas RICH
detectors
GSI meeting 20-21 November 2003
Afanasiev S.V.
JINR Dubna