Title: CEMSuite Plus


1
CEMSuite Plus
  • Emissions Data logging and presentation software

2
CEMSuite Plus
  • CEMSuite is a comprehensive, data logging package
    designed to work with continuous emissions
    monitoring systems. For some analysers with a
    serial output, the data can be exported directly
    to the host PC also, data can be acquired from
    systems with analogue outputs using our advanced
    interface unit.
  • The data is stored on the PC hard drive and is
    used for real-time presentation, historical
    graphing, alarms and customised reports. CEMSuite
    has advanced graphing capabilities to provide
    stunning visual displays of data to enable
    operators to clearly understand what is
    happening in their process and gives the ability
    to correct excursions before they become serious.

3
CEMSuite Plus
  • CEMSuite Plus is a data acquisition and reporting
    program that gathers data from either a single
    AMS or a number of groups of AMS.
  • It is designed to run on a p.c. using a Windows
    operating system.
  • It performs real-time data normalisation for
    pressure, temperature, oxygen and moisture.
  • It can capture data from 8 separate stacks, each
    with up to 16 gas/dust/pressure/temperature and
    process parameters.
  • Storage capacity is dependent on the size of the
    hard drive but normally about 10 years with a
    20GB hard drive.
  • Data can be displayed in text or graphical
    format.
  • Audible and visual alarms are available to warn
    operators of upset conditions.
  • CEMSuite is compliant with WID, LCPD and IPPC

4
CEMSuite Plus Components
  • CEMSuite consists of five inter-connected
    programs-
  • a) CEMCfg - sets up and stores all the required
    parameters such as normalisation and process data
  • b) CEMComm - collects data directly from the
    analyser or an Interface unit and stores it on
    the hard drive
  • c) CEMForm - the main data presentation program
  • d) CEMPort - a data management system that
    configures stored data for printing in report
    form or export to other programs such as
    spreadsheets and databases
  • e) CEMQual a module for calculating and
    displaying the QAL2, QAL3 and AST elements of BS
    EN 14181

5
CEMForm
  • CEMForm is the display module for CEMSuite Plus
    and measurement data is displayed in
    alpha-numeric and graphical form
  • CEMForm converts raw data from the database into
    a number of forms including mg/m3 and mg/Nm3
    using normalising data.
  • The trend screen shows graphical trends for
    selected measurands over user defined periods.
    This allows the operator to investigate incidents
    and long term trends
  • The trend screen also shows the plant status (on
    or off) and whether the averaged data is valid,
    according to European standards.
  • Two alarm thresholds are provided to advise
    operators when limits are being exceeded
  • An event log is provided so that explanations for
    events can be recorded by the operator

6
CEMForm - Real time data
7
CEMForm Trend screen
8
CEMForm Control screen
  • The Control screen has been devised for processes
    such as incineration and Gas turbines where the
    operator can control the process to regulate
    emissions levels.
  • The screen works off a pre-determined block
    average period (normally 30/15 minutes)and
    enables the operator to view the current average
    and the new average required to meet the ELV.
  • The screen also displays the number of valid
    minute averages within the block average
  • Using this page operators will able to regulate
    their emissions so that they never exceed the ELV

9
Control Screen
10
CEMPort
  • CEMPorts main function is to summarise the
    emission data into a format for submission to the
    environmental authorities or for internal
    reporting or analysis.
  • CEMPort enables an operator to create
    professional looking reports that can be output
    to a printer or saved to file. The program makes
    full use of Windows embedded printing facilities.
    Furthermore, data can be exported in CSV, HTML or
    Excel format to enable users to create their own
    reports.
  • The WID report is the standard format report for
    the EA and shows all the required parameters.

11
CEMPort Report Configuration
12
CEMPort Summary Report
  • There are three types of report available,
    Summary, Convert and Alarm. The format of the
    Summary report may be configured by the user to
    output the following -
  • Averaging period
  • Measurement groups
  • Raw or normalised or mass data
  • Averaged or block data
  • Measurands
  • Period of the report
  • Maxima
  • 95th Percentile

13
Summary report
14
CEMPort Convert Report
  • The format of the Convert report may be
    configured by the user to output the following-
  • Averaged output over a discrete period
  • Period of the report
  • Measurands
  • Measurement groups
  • Raw or normalised or mass data
  • Pre-configured reports can be printed at
    specified times like the end of the day or a
    shift. They can also be emailed automatically

15
Convert Report
16
WID Report
17
WID Report
  • This is the report requested by the Environment
    Agency from WID controlled sites.
  • It is easy to configure by the operator and
    performs all the calculations automatically.

18
CEMQual
  • CEMQual is a module designed to assist operators
    comply with the requirements of BS EN 14181
  • It accepts data input manually or retrieved from
    the CEMForm database automatically
  • It can perform all the key calculations for QAL2,
    AST and QAL3
  • It can produce CUSUM, Shewart and moving median
    graphs
  • All graphs and spreadsheet data can be printed or
    output as a JPEG picture.
  • Fully compliant with EN 14181 and validated by
    AEA Technology
  • With the addition of CEMCAL software and an
    Envirosoft supplied valve system, automatic zero
    and span tests can be undertaken at
    pre-determined intervals.

19
QAL2/AST analysis
20
Control Chart data entry
21
CUSUM Drift Chart
22
Shewart Chart
23
Moving Median Chart
24
Input unit
  • Accepts analogue inputs from most analysers
  • Will accept digital inputs (0-5V)
  • Supplied in an industrial weather proof cabinet
  • Low voltage directive (LDV) and CE compliant

25
Data Storage Unit
  • The DSU provides long term raw data storage
    (20Gb) and data back up
  • It carries out high speed data communications
  • It can provide data re-transmission from serial
    to analogue
  • It automatically updates the host PC if it is
    turned off for any period

26
Multi-analyser system with Input unit
27
CEMSuite Plus
  • We believe that CEMSuite Plus offers new levels
    of reliability and ease of use to operators of
    all kinds of regulated processes.
  • The program is easy to navigate and can be
    configured to cover most requirements.
  • The Software is written co-operation with the
    Regulatory authorities, current CEN standards and
    guidance to ensure full compliance.
  • Envirosoft is a specialist company that only
    creates data logging packages for environmental
    monitoring systems.
  • We offer peace of mind to operators of all
    processes because we can provide the expertise
    and service that they require to ensure they meet
    their regulatory obligations.
Write a Comment
User Comments (0)
About PowerShow.com