DiFis 2'0 3D Finite Element Neutron Kinetic Code - PowerPoint PPT Presentation

1 / 19
About This Presentation
Title:

DiFis 2'0 3D Finite Element Neutron Kinetic Code

Description:

Westinghouse PHOENIX-H code (XS) Westinghouse Advanced Nodal Code (ANC-H) Westinghouse 1D-3D neutron kinetic code TWINKLE (for PWR square FA lattice) ... – PowerPoint PPT presentation

Number of Views:104
Avg rating:3.0/5.0
Slides: 20
Provided by: alexsl4
Category:

less

Transcript and Presenter's Notes

Title: DiFis 2'0 3D Finite Element Neutron Kinetic Code


1
DiFis 2.0 3D Finite Element Neutron Kinetic
Code
17th AER Symposium on VVER Reactor Physics and
Reactor Safety
  • A.I. Zhukov and A.M. Abdullayev
  • NSC Kharkov Institute of Physics and Technology
  • September 24 - 28, 2007 Yalta, Ukraine

2
Objective
  • Existing 1D kinetic codes too conservative
  • SNRCU intend to require 3D analysis for accidents
    with reactivity insertion (Control Rod Eject
    Accident and others)

3
Background
  • Westinghouse PHOENIX-H code (XS)
  • Westinghouse Advanced Nodal Code (ANC-H)
  • Westinghouse 1D-3D neutron kinetic code TWINKLE
    (for PWR square FA lattice)
  • DiFis 1.0 3D FE steady-state code
  • FE methodology

4
Nuclear Model
2 group approximation

5
Thermal Hydraulic Model
Average Fuel Rod (one per assembly)

for fuel, gap, cladding
for coolant
6
Feedback Models
  • PHOENIX-H provides all XS with feedback
  • Moderator density correction includes
  • Diffusion coefficient correction
  • Moderator absorption correction
  • Boron concentration correction
  • Spectrum correction
  • Fuel temperature correction
  • Xe, Sm, Pm correction
  • Control Rod correction


7
Finite Element Technique - 1

Expansion of fluxes into series over linear
functions
Set of simplex-functions
Set of linear functions
8

Finite Element Technique - 2

Weighted Residual Equations
or
9
Finite Element Technique - 3

10
Finite Element Technique - 4

Fuel Rod Normally Fuel 7 zones Gap 2
zones Clad 5 zones Axial 24 zones
11
Code capabilities
  • Core Power vs. time
  • Spatial and time power distribution
  • Spatial and time temperature distribution in
    fuel, cladding and coolant

12
Example of Steady-State Calculations

EOC Relative FA Power ANC DiFis-ANC
Max Err 4.0 Rms Err 1.6
13
Example of Transient Calculations - 1

Control Rod Eject Accident
Timeline
start finish all banks start
to drop
finish
0 s 0.1 s 0.4 s

3.0 s
14
Example of Transient Calculations - 2
Rod Cluster Worth 0.18

15
Example of Transient Calculations - 3

Doppler only FA under ejected RCCA
16
Example of Transient Calculations - 4

All Banks drop FA under ejected RCCA
17
Example of Transient Calculations - 5

Doppler only FA under ejected RCCA
18
Example of Transient Calculations - 6

All Banks drop FA under ejected RCCA
19
Summary
  • DiFis 2.0 compatible with well-known codes such
    as PHOENIX-H and ANC-H
  • DiFis 2.0 provides accuracy 4 (in compare with
    ANC) for steady-state calculations
  • DiFis 2.0 justification and benchmarking to be
    continued
Write a Comment
User Comments (0)
About PowerShow.com