Clinical results of Hyperopic Wavefront LASIK
with the Bausch Lomb Zyoptix platform
  • Dr Haralabos Eleftheriadis, M.D
  • Ultralase Clinic Bristol UK

Financial Interest Travelling Grants received
from Bausch Lomb
2
Purpose
  • To study the visual and refractive results of
    hyperopia and compound hyperopic astigmatism
    treated with LASIK using the wavefront Bausch
    Lomb (BL) Zyoptix platform and flaps created
    with the femtosecond IntraLase laser

3
Methods 1
  • Hyperopic patients undergoing wavefront LASIK
    with the BL Zyoptix platform were studied
    prospectively
  • Flaps were created with the femtosecond IntraLase
    laser
  • Data were collected at months 1, 2, 3, 6 and at
    the time of discharge

4
Methods 2
  • Studied parameters were uncorrected visual acuity
    (UCVA), best-corrected visual acuity (BCVA),
    manifest refraction as well as safety, efficacy
    and predictability
  • Only eyes with preoperative manifest spherical
    equivalent (MSE) of 4.00 dioptres (D), BCVA of
    20/20 and target refraction of emmetropia were
    included in this study
  • Results at the time of discharge are presented
    below as mean standard deviation and range

5
Results 1
  • 114 eyes (56 right eyes)
  • 59 patients (33 male)
  • Age 527 years (range 38 to 65)
  • Preoperative MSE 2.110.82 D (range 0.75 to
    4.00)
  • Preoperative Sphere 2.470.87 D (range 1.00 to
    4.25 D)
  • Preoperative Cylinder -0.700.40 D (range -0.25
    to -2.50 D)
  • Time of discharge 8.33 months (range 3 to 22)

6
Results 2
Efficacy Index at Discharge 95.8
7
Results 3
Safety index at Discharge 98
8
Results 4
0.50 D 88 1.00 D 99
9
Results 5
0.5 D 84 1.00D 98
10
Results 6
Attempted vs Achieved SE at Discharge
OVERCORRECTED
Y-0.1101.093X, R20.88
UNDERCORRECTED
11
Results 7
Evolution of Spherical Equivalent
5
4
3
2
Spherical Equivalent
1
0
-1
Preop
Discharge
6 Months
12 Months
1 Month
2 Months
3 Months
9 Months
3 eyes (2.6) required enhancement procedures
12
Conclusions
  • Wavefront guided LASIK for hyperopia and compound
    hyperopic astigmatism with the Zyoptix Bausch
    Lomb platform and flaps created with the
    IntraLase femtosecond laser is
  • Highly effective
  • Very safe refractive procedure
  • It yields very accurate visual and refractive
    results