Title: 10th CST WMD Command Brief
1102 Civil Support Team (WMD)
Oregon National Guard LTC Lance E. Englet
2(No Transcript)
3102nd Civil Support Team (WMD)
Unit Mission The mission of the WM-CST is to
support civil authorities at domestic CBRNE
incident sites by identifying CBRNE agents and
substances, assessing current and projected
consequences, advising on response measures, and
assisting with appropriate requests for
additional support. This includes incidents
involving the intentional or unintentional
release of CBRBE and natural or man-made
disasters that result or could result in the
catastrophic loss of life or property in the
United States.
4102nd CST (WMD)Capabilities
- CBRN reconnaissance and survey
- CBRN sample collection
- Laboratory analysis of CBRNE samples (on-site)
- CBRNE agent research/reach-back to subject
experts - Communications - satellite, data imagery
- Limited Decontamination and Medical Support (No
mass decontamination or mass casualty care)
NOTE Team works jointly with state, local, and
federal EOD assets if requested.
5102nd CST (WMD) CAPABILITIES
- No-Notice Event Immediate Response
- HazMat 5 Request - Linn County Courthouse
Albany, OR - RPS Marion County Waste Transfer Facility
Salem, OR - RPS Schnitzer Steel Portland, OR
- HazMat 15 Request - USCG White Powder Call Coos
Bay, OR - HazMat 2 Request - Hynix White Powder Call
Springfield, OR - State Capitol Building Salem, OR
- RPS Radioactive Materials (RAM) transport vehicle
accident La Grande, OR - Salem Police Bomb Team assistance (HME ) Salem,
OR - Silverton Police /OSP Bomb Team assistance (HME)
Silverton, OR - Credible Threat Immediate Response
- Preplanned Event Deliberate Response
- Oregon Civil War Game Eugene, OR
- Olympic Trials Eugene, OR
- Klamath Falls Air Show Klamath Falls, OR
- Immediate Response
6102nd CST (WMD)Command Control
- In a state-controlled status, the CST (WMD) works
in support of the Incident Commander (IC) and the
CST (WMD) Commander takes direction from the IC. - In a federal-controlled status, the CST (WMD)
works for the designated military commander who
takes direction from the designated Command
Authority. - Individual CST (WMD) personnel remain under their
military chain of command.
7Operations Section
8INCIDENT COMMAND
MEDICAL SUPPORT
INCIDENT TRACKING AND OPERATIONS
DOWN-RANGE/DECON OPERATIONS
SAMPLE ANALYSIS
ON-BOARD 12.5 KW GENERATOR INMARSAT SATELLITE,
PHONE, FAX, INTERNET, EMAIL, PRINTER/PLOTTER,
TDIS AND DSS
UNIFIED COMMAND SUITE
9Communications Section
10Unified Command Suite (UCS)
OTHER CSTS AND MILITARY ASSETS
AVL 1.2M KU-BAND TERMINAL
15 KW GENERATER
VHF RADIO CONSOLE
CROSS-BANDING UHF/VHF/700 MHz USING ACU-1000
UHF RADIO CONSOLE
INCIDENT COMMANDER
SATELLITE PHONE, COMMERCIAL PHONE, HANDHELD
RADIO, LAPTOP W/ PRINTER AND INTERNET CONNECTION
11Medical Section
12Analytical Laboratory System (ALS)
- IR Spectroscopy
- Polarized Light Microscopy
- Fluorescence Microscopy
- White powder characterization
- Class III Bio-Safety Level 4
- Negative Pressure Glove Box
- Safe manipulation of weapon-ized agents
- GC/MS
- Range of 1 to 1050 atomic mass units
- Vapor/boiling point, atomic mass
characterization - Unknown chemical identification
- Bio-Veris Protein Detection
- Specific protein analysis for
- specific Bio-agents
- RAPID Polymerase Chain Reaction
- DNA analysis of Bio-warfare agents
13Medical Support
- Medical Operation Officer
- Medical logistics and support
- based On Hazmat intelligence
- Site Safety Officer Liaison
- Decontamination Officer
- Knowledge of local health
- care supporting infrastructure
- Physician Assistant
- Board certified, State licensed
- Provides primary care for CST personnel
- Advises emergency first responders and
- health care providers on effects of CBRNE
- causative agents to the population
MEDICALTREATMENT MONITORING ADVANCED LIFE
SUPPORT, ENVIRONMENT MONITORING, COMMUNICATIONS
HOSPITAL
14Decontamination Section
15Decontamination Line
Both Decon Lines are designed for First
Responders and 102nd CST (WMD) Personnel, NOT
Mass Decon.
- Technical Decon Line
- 30 Minute Set Up, Water Source Required.
- Use Soap and Water for Most Agents, or Bleach
- with Required Contact Time for Biological
Agents. - Emergency Man Down Decon Conveyor
- System.
- All Waste Water is Collected.
- Designed for Toxic Industrial Chemicals,
- Chemical Warfare Agents, Biological Agents.
- Dry Decon Line
- Designed for Radiation Response, Chemical
Warfare Agents, or if Water is Unavailable. - Activated Charcoal via M295 and M291 Kits, or
Hypewipes Containing Sodium Hypochlorite are used
as Decon Material. - 15 Minute Set Up.
Equipment Used on Both Lines Multi Rae PID, Army
ICAM ACADA, PDR-77.
16Survey Section
17Preliminary Monitoring Team
- Establishes Hot, Warm and Cold Zone
- Determines left and right limits of Decon Line
- Ensures no gross contamination in Area of Ops
18Recon/Site Characterization
- Outside Reconnaissance
- Determines presence of possible release
- External evaluation of public life and safety
19Recon/Site Characterization
- Characterizes an unknown contaminated
environment - Low tech to high tech evaluation of the possible
CBRNE threat
- JOINT ENTRY
- FBI
- EOD
- SWAT
- Hazmat teams
20Sampling
- All sampling is conducted in accordance with the
FBIs 12 step - sampling and evidence preservation procedures
- Samples are split for confirmatory analysis at
the State Lab
- Downrange Analytical Ability
- Hazmat ID
- Ahura First Defender
- Hapsite GC/MS
21102 CST Alert Process
INCIDENT
Incident Commander
Oregon Emergency Response System (1-800-452-0311)
Oregon Military Department
Oregon Joint Operations Center
Follow on Federal Resources 72 Hours
102 Civil Support Team
Arrive at Incident Location
90 Minute Departure to Incident Location
22102 Civil Support Team (WMD)
CONTACT INFORMATION and PROCEDURES Oregon
Emergency Response System (OERS) 1-800-452-0311 A
t no Cost to the Requesting Incident
Commander! LTC Lance Englet, Commander (503)
932-2837 / lance.englet_at_us.army.mil MAJ Demian
San Miguel, Deputy Commander 503-576-0151 /
demian.sanmiguel_at_us.army.mil