Group 6: Optical Heart Monitor Jump Drive - PowerPoint PPT Presentation

1 / 13
About This Presentation
Title:

Group 6: Optical Heart Monitor Jump Drive

Description:

... 6: Optical Heart Monitor / Jump Drive. Sponsor: Calit2. Mentor: Paul Blair, ... Optical Heart Monitor project is to develop a cheap, reliable, easy to use heart ... – PowerPoint PPT presentation

Number of Views:81
Avg rating:3.0/5.0
Slides: 14
Provided by: jeffr63
Category:

less

Transcript and Presenter's Notes

Title: Group 6: Optical Heart Monitor Jump Drive


1
Group 6 Optical Heart Monitor / Jump Drive
  • Sponsor Calit2
  • Mentor Paul Blair, Ph.D.
  • Team Kari Nip, Matt Chandrangsu, Jeffrey Chi

2
Agenda
  • Project Background
  • Weekly Progress
  • Statement of Work
  • Gantt Chart
  • Summary
  • Plans for Next Week

3
Project Background
  • Currently there are many heart rate monitors in
    use that enable a user to check up on his or her
    own heart health, but there are not many
    applications using heart rate monitors that allow
    users to save their heart rate data to view later
    for medical purposes. Many existing monitors are
    also bulky and hard to use, and also sometimes
    unreliable.
  • The purpose of the Optical Heart Monitor project
    is to develop a cheap, reliable, easy to use
    heart monitor that not only gives real time data,
    but is able to store the data to see changes over
    time.

4
(No Transcript)
5
(No Transcript)
6
Weekly Progress
  • - Met with Paul Blair to discuss project details
    and goals
  • - Started to familiarize with programming
    microcontrollers

7
System Block Diagram
Optical Sensor
Analog/Digital Converter
AVR Microprocessor
Flash Memory
Computer
Database
8
Statement of Work
  • Project Features
  • Signal Collection
  • Improve upon previously designed optical heart
    rate collection circuitry.
  • Use designed circuitry to obtain analog signal of
    the users heart rate.
  • Analog to Digital Signal Conversion / Signal
    Processing and Filtering
  • Take analog signal of users heart rate and
    manipulate using digital filters to obtain time
    differences between heart beats from the optical
    sensor.
  • Interface to Existing Code
  • Implement code that calculates the heart rate
    from the time differences between heart beats.
  • Enable heart rate data to be saved onto external
    flash memory.
  • Integrate code that allows the heart rate data to
    be read from device just like a USB jump drive on
    a computer.
  • Integrate Components / Construct PCB

9
Statement of Work
  • Deliverables
  • Completed PCB
  • Software for integrating USB drive
  • Analog to digital conversion code
  • Documentation of work

10
Statement of Work
  • Resources Required
  • Bread board for development
  • Eagle program for schematic capture and layout
  • AVR programs for microcontroller code development
    and microcontroller programming.
  • Device elements microcontroller, pulse
    oximeter, resistors, capacitors, opamps, etc

11
Gantt Chart
12
Summary
  • Met with mentor to discuss project
  • Determined high level flow diagram
  • Understood the expectations for the project for
    this quarter

13
Plans for Next Week
  • Complete microcontroller tutorial
  • Begin to understand existing code, and circuit
    design
  • Distributing tasks
Write a Comment