Title: Russian pressurized water reactor VVER440
1Russian pressurized water reactor VVER-440
- Alexei Soldatov
- Russian Federation
2Presentation Outline
- Introduction Some history of Russian Nuclear
energy - NPP with VVER 440 (Project 230 213)
- General design of VVER 440 (230 / 213)
- Hardware of VVER 440 primary loop
- VVER 440 operating systems
- VVER 440 safety systems
- Conclusion
3History of Russian nuclear energy
Experimental reactors
4History of VVER type reactors
VVER 210 experimental build in Novovoroneg NPP
VVER 365 experimental build in Novovoroneg NPP
VVER 440 / 187 first Pre-generation (2 units)
VVER 440 / 230 first generation of VVER
VVER 440 / 213 second generation of VVER
VVER 1000 third generation of VVER
VVER 1000 AES 92 - Basic design
VVER 640 / NP640 (1 unit under construction)
AST 500 NPP for thermal energy production
5VVER 440 is an international reactor type of
reactor
- In the Soviet period most of East European
countries build VVER 440 - Bulgaria, Hungary, Czech Republic, Slovak
Republic, Finland, East Germany, Ukraine,
Armenia, Cuba. - More then 30 units all over the world
6General Design of NPP with VVER 440
- All NPP with VVER 440 have Twins design.
- 2 Reactors are placed in the same reactor
building. - Each reactor has two 220 MW turbines
- Each reactor operated from his own control room
7General Design of NPP with VVER 440
- Twins design have some advantages
- Ability to use one support system for both units
- Ability to use steam from Unit 2 for starting
Unit 1 - Twins design is also good for economical
reasons
8General Design of NPP with VVER 440
- Twins design have some disadvantages
- Dependence between two units in the case of
emergency - No containment
- Higher potential irradiation of personal
9VVER Primary Loop
10VVER 440Primary Loop. Reactor
Main parameters of reactor Thermal Power 1375
27 MWe Number of Cold / hot legs
6/6 Pressure inside reactor 125
Atm Temperature (Cold leg) 270 ? Temp. rise
across the core 30 ? Water flow through the
core 41 000
m3/hr
11VVER Primary Loop, Steam generator
12VVER Primary Loop
Steam generator parameters
13VVER Primary Loop
Main coolant pump Productivity 7100 m3/
hr Operating pressure 125 Atm Charge (delta P)
40,25 Atm Power at hot/cold water 1400 / 1600
kWt
14VVER Primary Loop
Pressurizer Nominal temperature 325 ? Nominal
pressure 125 Atm Temperature at work 335 ?
Pressure at work 140Atm Volume (Steam/water) 18
/ 26 cubic meters
15VVER Primary Loop
Pressurizer work graph
16VVER 440 systems of primary loop
- Reactor coolant system
- Chemical volume control system
- Passive Injection System
- Emergency boron injection system
- Emergency core cooling system (high low
pressure injection - Sprinkler system (Like containment spray
system) - Compressors Pumps support System
17VVER 440 systems of primary loop
- Barbatage condensate system
- Steam generator cleaning system
- Cooling water cleaning system
- MCP support system
- MCP oil seal system
- Spend fuel cooling system
- Leakages control system
- Boron storage system
18CVCS
CVCS
19Passive injection system
20Emergency Systems(See at the transparences)
- Emergency boron injection system
- Emergency core cooling system (high low
pressure injection - Sprinkler system (Like containment spray
system)
21Conclusion
- VVER 440 reactor well operated since 1968
- During this operation they show their safety and
ability keep control in emergency situation - Experience of work with VVER 440 makes possible
to develop new VVER 1000 VVER 640 (Medium
power, increased safety project)