Title: Backward Congestion Notification Version 2.0


1
Backward Congestion Notification Version 2.0
  • Davide Bergamasco (davide_at_cisco.com)
  • Rong Pan (ropan_at_cisco.com)
  • Cisco Systems, Inc.
  • IEEE 802.1 Interim Meeting
  • Garden Grove, CA (USA)
  • September 22, 2005

2
Credits
  • Valentina Alaria (Cisco)
  • Andrea Baldini (Cisco)
  • Flavio Bonomi (Cisco)
  • Manoj K. Wadekar (Intel)

3
BCN v2.0
  • Desire from Mick to see an analytical studyof
    BCN stability
  • BCN v2.0 improvements
  • Linear control loop allows analysis of stability
  • Simplified detection mechanism
  • Reduced signaling rate
  • Original BCN framework remains the same

4
BCN Background
5
Detection Signaling
6
Reaction
7
Suggested BCN Message Format
0 15
31 ------------
--------------------

DA SA of sampled
frame ----------------

------------
---- SA MAC Address of CP

------------
--------------------
IEEE 802.1Q Tag or S-Tag
------------
--------------------
EtherType BCN Version
Reserved -----------
---------------------


CPID

-----------
---------------------
Qoff
Qdelta ----------
----------------------
Timestamp
----------
------

First N
bytes of sampled frame starting from DA


-------------------------
-------
FCS
-------------------------
-------
8
Suggested RLT Tag Format
0 3 7 15
31 -----------
---------------------

DA of rate-limited
frame ----------------

-----------
----- SA of rate-limited frame

-----------
---------------------
IEEE 802.1Q Tag or S-Tag of
rate-limited frame -----------
---------------------
EtherType RLT Version
Reserved -----------
---------------------


CPID

-----------
---------------------
Timestamp EtherType of
rate limited frame --------------
------------------

Payload of rate-limited
frame

------------------------
--------
FCS
------------------------
--------
9
Simulation Environment (1)
TCP Bulk
UDP On/Off
Congestion
10
Simulation Environment (2)
  • Short Range, High Speed DC Network
  • Link Capacity 10 Gbps
  • Switch latency 1 ?s
  • Link Length 100 m (0.5 ? s propagation delay)
  • Control loop
  • Delay 3 ?s
  • Parameters
  • W 2
  • Gi 4
  • Gd 1/64
  • Ru 8 Mbps
  • Workload
  • ST1-ST4 10 parallel TCP connections transferring
    1 MB each continuously
  • SU1-SU4 64 KB bursts of UDP traffic starting at
    t 10 ms

11
BCNv1.0
12
BCNv2.0
Faster Transient Response
Higher Stability _at_ Steady State
13
Simulation Environment (3)
  • Long Range, High Speed DC Network
  • Link Capacity 10 Gbps
  • Switch latency 1 ?s
  • Link Length 20000 m (100 ? s propagation
    delay)
  • Control loop
  • Delay 200 ?s
  • Parameters
  • W 2
  • Gi 4
  • Gd 1/64
  • Ru 8 Mbps
  • Workload
  • ST1-ST4 10 parallel TCP connections transferring
    1 MB each continuously
  • SU1-SU4 64 KB bursts of UDP traffic starting at
    t 10 ms

14
BCNv1.0
15
BCNv2.0
Much higher stability _at_ steady state with larger
loop delays
16
Summary
  • BCN v2 has a number of advantages
  • Can be studied analytically
  • Better protection of TCP flows in mixed TCP and
    UDP traffic scenarios
  • Detection algorithm independent of Switch
    implementation
  • Better Performance
  • Lower signaling frequency (from 10 to 1)
  • Better stability
  • Increased tolerance to loop delays
  • and one disadvantage
  • Slower convergence to fairness

17
A Control-Theoretic Approach to BCNDesign and
Analysis
18
Notation
N Number of Flows C Link Capacity ? Round
Trip Delay w Weight of the Derivitive Pm
Sampling Probability Gi Additive Increase
Gain Gd Multiplicative Decrease Gain
19
Block Diagram of BCN Congestion Control
C

q
R

?R
_


Gd
_
Time Delay

Pm
Gi
20
Non-linear Differential Equations
Link Control
Source Control
If Fb(t-?) gt 0
If Fb(t-?) lt 0
21
Linearization Around Operating Point
  • Using feedback control to analyze local stability
  • Operating point
  • R C/N
  • q qeq q 0
  • Linearization
  • Difficulty depending on sgn(Fb(t-d)), the system
    responses are different
  • Luckily, a piecewise-linear function
  • Details are in the appendix

22
Block Diagram of BCN Feedback Control
?R

?q

lose 90o margin
Multiplicative Decrease
_
?Fb
Additive Increase

23
The Effect Of Zero From Time Domains Eyes
R
q
24
Choosing Parameters an example
  • Network conditions (10G link)
  • N 50
  • ? 200us
  • Choose parameters such that the feedback loop is
    stable with a 35o margin
  • w 4
  • Gi 2Mbps
  • Gd 1/128
  • Pm 0.01

25
Stability Result
lost 90o margin
26
Simulation Result Shows A Stable System for N
50 Delay 200us
27
Simulation Result Shows System is stable, but on
the verge of oscillation N 50, Delay 1ms
28
Change W 4 -gt 1
29
Indeed System is stable, but on the verge of
oscillation even for N 50, Delay 200us when w
1.0
30
Requests to 802.1
  • Start a Task Force on Congestion Management
  • Use BCN as a Baseline Proposal

31
Appendix
32
Linearizing
33
Linearizing Additive Increase Function
34
Linearizing Additive Increase Function
35
Linearizing Multiplicative Decrease Function
36
Linearizing Multiplicative Decrease Function
37
Issue 1 Non-linearity
Q
  • ISSUE Overshoots and undershoots accumulate over
    time
  • SOLUTION Signal only when
  • Q gt Qeq dQ/dt gt 0
  • Q lt Qeq dQ/dt lt 0
  • Easy to implement in hardware just an Up/Down
    counter
  • Increment _at_ every enqueue
  • Decrement _at_ every dequeue
  • Reduces signaling rate by 50!!

Stop Generation of BCN Messages
-
-
-
-




Qeq
t
38
Issue 2 Specific Detection Mechanism
39
39
39
39