V' Issakov - PowerPoint PPT Presentation

1 / 5
About This Presentation
Title:

V' Issakov

Description:

... new estimate of the energy resolution will be done with a modernized procedure ... We propose using the same Calorimeter prototype to study prototypes of the ... – PowerPoint PPT presentation

Number of Views:35
Avg rating:3.0/5.0
Slides: 6
Provided by: vladimir97
Category:

less

Transcript and Presenter's Notes

Title: V' Issakov


1
V. Issakov Physics Department, Yale University,
New Haven, CT 06511 Tech.board meeting, 24
May 2005
2
  • Energy and time resolution of the combined
    Preradiator/Calorimeter system
  • We have to do a new, more realistic calculation
    of the energy/time resolution for the P/C system
    to show possibility to reach the required
    resolutions
  • ?E 2.7/?EGeV, ?T 90psec/?EGeV.
  • The new estimate of the energy resolution will be
    done with a modernized procedure for calculation,
    including simulation of a detectors calibration
    and subsequent correction of their signals.
  • Main problem is calibration and correction of the
    Preradiator signals in present design (a X-Y
    plank geometry) of the Preradiator scintillators.

3
(June October 2005) 1. Uniformity of the
Calorimeter response (energy value energy
resolution) versus incident point and angle of
photons Our Monte Carlo calculation and a
preliminary measurement with cosmic muons have
shown, that uniformity of the Calorimeter
response to photons is better than 1. However,
the direct measurements of this uniformity have
not been done to check our prediction. IHEP has
produced and delivered to BNL the 25
pre-production calorimeter modules. We will
build a new prototype of the Photon Calorimeter -
an array of 5 ? 5 modules with a prototyped
version of its HV, Cooling, Monitoring,
WFD-readout instrumentation. In autumn of 2005,
this prototype will be employed to test
uniformity of the Calorimeter response on a LEGS
tagged photon beam.   2. Final specifications
for the Calorimeter subsystems (HV, Cooling,
Monitoring and WFD-readout)  We propose using the
same Calorimeter prototype to study prototypes of
the mentioned Calorimeter subsystems to adjust
their final specifications.   Minimal cost of
the prototype instrumentation is 59,825. 43,150
is an already reserved fund (SBU and
YALE). 16,675 is an additionally required fund
(KOPIO Project Office).
4
  • (October 2005 October 2006)
  • WBS-1.2.3.1 Mockup of Calorimeter System
  • Construction and test of a 16?8 array of
    mass-produced modules with appropriate
    pre-production prototypes of the Cooling,
    High-Voltage, Monitoring and WFD-readout systems
    to test the energy and timing performance of a
    combined Calorimeter/Preradiator system and the
    performance characteristics of the DAQ-system
    prototype.
  • The design/production/shipping cost of the
    Calorimeter System Mockup is 505k.
  • WBS-1.2.3.2.1 Design of Photon Calorimeter
  • Conceptual design and a completed
    technical design of Photon Calorimeter. Design
    cost is 50k.

5
  • The short-term Calorimeter RD (June October
    2005) will be covered by an existed
    KOIPO/YALE/IHEP MoU.
  • The long-term Calorimeter RD (first year of the
    Calorimeter construction stage) will need two
    separate MoUs (KOPIO/YALE and KOPIO/IHEP), which
    we start to discuss and draft now.
Write a Comment
User Comments (0)
About PowerShow.com