Network Time Machine - PowerPoint PPT Presentation

1 / 33
About This Presentation
Title:

Network Time Machine

Description:

Four Models. Economy 'Mini -Recorder' Low cost. 0.9TB storage volume (No separate storage unit) ... Four Models. ClearSight Confidential. Support NICS. NTM ... – PowerPoint PPT presentation

Number of Views:118
Avg rating:3.0/5.0
Slides: 34
Provided by: clearsi
Category:
Tags: machine | mini | models | network | time

less

Transcript and Presenter's Notes

Title: Network Time Machine


1
  • Network Time Machine
  • Demo

2
Network Time Machine(NTM)
  • Overview
  • NTM demo Installation
  • Demo

3
Four Models
  • Economy Mini -Recorder
  • Low cost
  • 0.9TB storage volume (No separate storage unit)
  • Post-analysis only
  • GA. Mar. 07
  • Basic Standard-Recorder
  • 1.8TB storage volume (No separate storage unit)
  • Full (Real-time and Post) CSA analysis
  • GA. Jan. 07

4
Four Models
  • High Performance Premium-Recorder
  • 3.3TB storage volume
  • Expandable up to 3 storage units, 10TB (extra
    storage)
  • Full (real-time and Post) CSA analysis
  • GA. Dec. 06
  • Handy Portable-Recorder
  • 0.4TB storage volume
  • Full (Real-time and Post) CSA analysis
  • GA. Apr. 07

5
Support NICS
  • NTM supports two kinds of NICS-XL2 and XD

6
Realtime Traffic Data
  • Trending traffic data over a long-duration

7
Feature Overview
  • Graphs display trend figure of each parameter.

8
Feature Overview
  • Save history captured data

9
Feature Overview
  • Show detail statistics and trending graphs of
    captured data

10
NTM demo Installation
  • Hardware Requirement
  • There should be 2GB available space on drive C
    at least.

11
Apply license for NTM
  • Installation Steps
  • 1. Launch NTM install program, and make
    sure the directory is C\ProgramFiles\ClearSight
  • 2. Reboot PC as prompt after
    installation
  • 3. Copy the following 3 files to the
    install directory (C\Program Files\ClearSight)
  • NetworkRecorderEngine.dll
  • XYCommonInterface.dll
  • libdb44.dll
  • 4. Run Start - Program-ClearSight-Clear
    Sight Time Machine, and click Cancel button in
    ClearSight Networks Activation dialog box.
  • 5. Right click general.xml to choose
    Edit.(C\Program Files\ClearSight\config)
  • Change the value of
    loopbackDriverType to 12. Save the file and exit.
  • 6. Copy the two folders packetstore and
    metadatastore to the root directory under drive
    C.
  • 7. Copy folder demo to the install
    directory (C\Program Files\ClearSight)
  • 8. Right Click My Computer, choose
    Properties- Advanced, Environment Variables, and
    make sure NR_Disk_GB_SIZE is 0 in system
    variables.
  • 9. Send registration.xml is located on
    C\Program Files\ClearSight to license_at_clearsightn
    et.com or support.asia_at_clearsightnet.com with
    version number to apply license.
  • 10. Run Start-Programs-ClearSight-Cle
    arSight Network Time Machine,
  • Active NTM use license in ClearSight Networks
    Activation dialog box.
  • Click OK in ClearSight Login dialog box,
  • Click Refresh in the next Open Adapter dialog
    box,
  • Then choose ClearSight Networks Loopback
    Adapter and click OK.

12
NTM UI
13
Feature Overview
  • Capture Data
  • Filter captured data
  • Lock captured data
  • Auto Save Trace captured data
  • Record
  • Realtime trending graph and statistics
  • History trending graph and statistics
  • Save data

14
Display Captured Data on Physical
  • Statistics of Physical Layer and trending graphs
    of corresponding options are displayed on
    Physical.

15
Display Captured Data on Network
  • Statistics of Network Layer and trending graphs
    of corresponding options are displayed on
    Network.

Settings should be made to display Network data.
16
Filter Captured Data
  • Filter settings can be made to capture data
    needed from network.

17
Lock Captured Data
  • Time-Based
  • To lock captured data during specific period
    automatically.
  • SNMPTrap-Based
  • To lock captured data during the time SNMP trap
  • occurs automatically.

18
Lock Captured Data
19
Auto Save trace
  • Auto save trace during capture according to
    configure filter.

20
Realtime Record
21
Detail
22
Channels
23
Distribution
24
History
  • Recording each capture information makes it easy
    to look up in history data for review.

25
Export Statistic
  • The statistics in this record can be exported to
    CSV files.

Export data in specific trending segment to CSV
files
26
Lock
  • Lock Record can be used to lock this record,
    even more to lock the data during specific period
    in this record for detail analysis.

27
Trending-Total
  • Double-clicking record or clicking Show Trend
    can view the detail statistics and trending
    graphs relating to this record.

28
Trending-Part
  • A period in history record can be specified to
    show its statistic and trending graphs.

Specify and zoom in to the interesting data filed
29
Tracefile
  • Show Trace can be used to view the tracefile
    for this record.
  • Save Trace can be used to save the tracefile
    for this record.

30
Save Tracefile
Filters and Slicing Reduce data size on demand
Trace files Saving tracefile for post analysis
31
Filter Saved Data
  • Captured data can be viewed and saved by setting
    conditions.

32
Improve Storage Performance
  • When capturing data, Realtime Monitor can be
    stopped to improve the storage performance and
    reduce CPU utilization.

33