1New Features for Cscape 4.5
2Added Integer Scale Function
This allows integer values to be quickly scaled.
3Added BYTE and DWORD Move Functions
4Added BYTE Compare Functions
5Find Now Supports Finding Ladder Functions
6Auto Assignment of Next Available Register
Enter a ? in place of the register number, and
the next available register number will be
automatically selected.
7Added a Limit Function
This function checks if a INT, DINT or REAL
register is with-in the specified range.
8Constants Can Be Entered As Hexadecimal or Binary
For hexadecimal make sure the value starts with a
number 0-9 then place an h to specify hex. For
binary numbers just place a b after the value.
9Faster Graphics Handling
Compiling and checking graphics is now 2 to 8
times faster.
10Support for New Smart Stack Modules
DIM310, DIM410, DQM306, DQM406, DQM902, MIX904,
MIX912
16 and 32 point 24V input, 16 and 32 point 24V
output, 20 relay, digital I/O with isolated
analog, digital I/O (pos outputs) with analog.
11Added Support for the DAC202 Smart Stack Module
This module provides 8 output channels of 0 to 10
volts or 0 to 20 mA selectable on a per channel
basis.
12Added Support for the MIX963 Smart Stack Module
13Added Support for the DIQ627 Smart Stack Module
14Added Support for New Mini OCS Models
Added OCS055, 085,057, 087, 038, 068, 049, 079
15Added Support for Mini RCS
Added software support for unreleased new
hardware models.
16Added Support for OCS110 and OCS210
Software support for unreleased hardware models
OCS110 and OCS210. These add additional
register, ladder and text screen space.
17Alarm Handler Function Block
This function allows a block of screens to be
assigned to display alarm conditions.
18Alarm Handler Function Block
- This function block handles
- Pending flags
- Acknowledge flags
- Time stamping (optional)
- Event counting
- Key/Input handling
- Screen Navigation
19Communication Support for the CGM500/502 ISA Card
20Communication Support for the ESD Brand CAN Cards
This provides ISA, PCI, and USB connectivity from
the PC to the CsCAN network.
21Support for 2nd Serial Port on the OCS250
22Increased Number ofText Fields
Up to 16 fields per screen or 15 fields per menu
screen.
23Module Configurations Can Be Cut, Copied or Pasted
Right click on a module slot to cut, copy or
paste the I/O Module and its configuration.
24I/O Configuration Allows Inserting a Module
This allows adding a module in the stack without
re-entering the configuration.
25Added Auto Select for Editing
This feature selects a field for editing as soon
as it is displayed. This eliminates the need for
the operator to press ENTER before editing a
field.
26Increased Memoryfor the OCS250
- 128K of Ladder
- 256K of Graphics Objects
- 256K of Compressed Bitmaps
27Background ColorCan Be Selected
28Right Click on Jumps or Calls to Find the
Matching Label
On any JUMP or CALL, right click and select Find
Label to move to the label that matches the JUMP
or CALL.
29Support for 9,999 R Registers on the OCS250
Only Move instructions will support the expanded
R registers for now.
30Overriding I/O Registers
This allows contacts and coils to simulate or
force physical or network I/O for testing or
troubleshooting.
31Total and Individual Network Usage Can Be
Displayed