Title: Energy Rated Homes of Utah Utah Energy Conservation Coalition
1Energy Rated Homes of UtahUtah Energy
Conservation Coalition
2Duct System Diagnostic Field Guide
3Diagnostic Tools
P Digital Monometer P Flow Hood P Blower
Door P Duct Blaster P Pressure Pan P Door
Gauge P CO Tester
4Digital Manometer
- Measures Pressure Differences
- lt Determines Zonal Pressure
- lt Plenum Pressure
- lt Determine Dominant Duct Leak
- lt Declare Duct Location
- lt Combustion Appliance Z? Test
- lt Chimney Draft Test
5Flow Hood
P Measures Airflow lt Supply Flows lt Return
Flows lt Ventilation Flows
6Blower Door
P Measures House Leakage Area lt CFM 50 Test lt
Duct Leakage Tests lt Minimum Ventilation Level
(MVL)
7Duct Tester
P Quantify Duct Leakage lt Total Leakage lt
Leakage to Exterior lt Supply/Return Leakage lt
Air Handler Fan Flow
8Pressure Pan
P Qualitative Test for Duct Leakage
9CO Monitor
P Measures Carbon Monoxide lt Ambient Test lt
Appliance Test
10Door Gauge
P Determine Area Required to Provide Pressure
Relief Between Rooms
11Field Testing
12Dominant Duct Leak Test
13Dominant Duct Leak Test
P Measure pressure across the building
envelope. ltAir handler off ltAir handler on
P Calculate the difference.
2.4PA Indoors WRT outdoors, Air Handler
off. 0.3PA Indoors WRT outdoors, Air Handler
on. -2.1PA Air Handler Induced Pressure.
14Dominant Duct Leak Test
15Dominant Duct Leak Test
16Basic Blower Door Test (CFM 50)
17Basic Blower Door Test (CFM 50)
18Record Data Determine CFM50
P Fan Pressure P Hole Size (ring size) P CFM50
from the tables in the book
19Locate Air Leakage Paths
20Read Zone Pressures
21Read Zone Pressures
22Read Zone Pressures
23Read Zones Pressures
24Duct Pan/Block Test
25Pressure Pan
26Pressure Block
27Pressure Pan/Block Test
28Develop a Profile of Duct Leaks
29Define Leak Location
30Split System Pressure Pan Test
31Total Duct Leakage
32Total Duct Leakage
33Duct Leakage to Outdoors
34Duct Leakage to Outdoors
35Duct Leakage to Outdoors
36Duct Leakage to Outdoors
37Duct Leakage to Outdoors
38Duct Leakage to Outdoors
39Duct Leakage to Outdoors
40Combustion Appliance Safety Tests
41Carbon Monoxide Testing??
42(No Transcript)
43(No Transcript)
44CAZ Test-Air Handler Effect Interior Door Set Up
45CAZ Test-Air Handler Effect Interior Door Set Up
46CAZ Test-Air Handler Effect Interior Door Set Up
47(No Transcript)
48Set Up Worst Case CAZ Pressures
P Basic Procedure lt Close all exterior doors
and windows lt Turn on the Air Handler lt Close
all interior doors lt Turn on all exhaust
devices lt Measure CAZ WRT outdoors
Is the CAZ depressurized in excess of the
recommended house Depressurization Limits?
49(No Transcript)
50(No Transcript)
51(No Transcript)
52(No Transcript)
53After Duct Sealing Prediction
54(No Transcript)
55(No Transcript)
561994 UMC 706
- Conditions Created By Mechanical Exhausting
P Operation of exhaust fans, kitchen ventilation
systems, clothes dryers or fireplaces shall be
considered in determining combustion air
requirements to avoid unsatisfactory operation of
installed gas appliances.
57House Depressurization Limits (HDL)
58Utah Energy Conservation Coalition Energy Rated
Homes of Utah