Transcript and Presenter's Notes

Title: Doylestown Fire Company


1

Doylestown Fire Company
__________________________
__________________________
Pump Operations
2
HydrantsColor / Flow
  • Blue
  • 1500 gpm
  • Green
  • 1000 gpm 1500 gpm
  • Orange
  • 500 gpm 1000 gpm
  • Red
  • 250 gpm 500 gpm
  • Black
  • Static 250 gpm

3
HydrantsColor / Flow

4
General Information
  • Friction Loss
  • Each Appliance 20 psi loss
  • 10 psi loss per story
  • L-79 _at_ elevation and extension has
    30 psi loss

5
General Information
  • Miscellaneous
  • 5 hose takes 1 gallon per foot to fill
  • Engine to engine supply should use 3 hose
  • Deployment of 5 should be at 30 mph
  • Always try to keep 20 psi residual coming into
    your truck

6
Operating Pressures
  • TFT
  • 100 psi at the tip

7
Operating Pressures
  • Straight Bore
  • 50 psi at the tip

8
Operating Pressures
  • Ground Monitor
  • 100 psi at the tip with TFT
  • 80 psi at the tip with Straight Bore

9
Operating Pressures
  • Push Back Pressure is Approximately
  • ½ the Operating Pressure at the Tip
  • (100 psi 50 lbs force)

10
5 Supply Line
  • Friction Loss
  • Water Flow

11
5 Supply Line
  • Friction Loss
  • 500 gpm 3 psi / 100 feet
  • 1000 gpm 6 psi / 100 feet
  • 1500 gpm 9 psi / 100 feet

12
5 Supply Line
  • Friction Loss
  • 500 gpm 30 psi / 1000 feet
  • 1000 gpm 60 psi / 1000 feet
  • 1500 gpm 90 psi / 1000 feet

13
3 Supply Line
  • Friction Loss
  • GPM Squared x Feet of Hose

14
3 Supply Line
  • Example 1
  • 700 gpm, 500 feet of 3 hose, TFT stinger
  • 7 squared 49 x 5 sections (500) 245 psi
  • TFT 100 psi
  • Appliance 20 psi
  • Total 365 psi

15
3 Supply Line
  • Example 2
  • 500 gpm, 700 feet of 3 hose, TFT stinger
  • 5 squared 25 x 7 sections (700) 175 psi
  • TFT 100 psi
  • Appliance 20 psi
  • Total 295 psi

16
3 Supply Line
  • Example 3 - Yamaha
  • 100 gpm, 200 feet of 3 hose, 1 100 2 TFT
  • 1 squared 1 x 2 sections (200) 2 psi
  • TFT 100 psi
  • Appliance 20 psi
  • Total 122 psi

17
Standpipe Operations
  • Example 1 3rd floor parking garage 100 gpm
  • 3 x 10 30psi 100psi (TFT) 20 psi
    (Appliance) 150 psi
  • Example 2 6th floor of the court house 100
    gpm
  • 6 x 10 60psi 50 psi (Straight bore) 20 psi
    (Appliance) 130 psi
  • Example 3 6th floor of the court house 200
    gpm with TFT
  • 70psi 100 psi (TFT) 60 psi 230 psi
  • Example 3 6th floor of the court house 200
    gpm
  • with Smooth Bore
  • 70psi 50 psi (Smooth Bore) 60 psi 180 psi

18
Standpipe Operations
  • 10 psi per floor
  • nozzle operating pressure
  • friction loss per appliance

19
Sprinkler System Operations
  • Operating Pressure 150 psi

20