Title: SNS Fast Beam Loss Monitors Final Design Review
1 SNS Fast Beam Loss Monitors Final Design
Review
2BLM System Design Features
- Ion Chambers
- Wide Dynamic Range (IC 6 Decades) (2 dn, 4 up)
- Gain adjustment (per channel)
- Beam intensities
- Detector shielding
- Response Time
- Ion Chamber
- Micro-second response. Data can be available for
multi-turn, per cycle, and per second intervals. - Order of 5-10 turns to generate Permit Link Fail
(35 KHz BW 10us) - FBLM, Liquid Cell/ PMT
- Fast (ns), within turn loss data
- Wide dynamic range
- FBLM Test
- LED mounted inside Scintillator/PMT assembly
- Can be pulsed remotely
3BLM Distribution
Total 18 FBLMs
4HEBT Loss Monitors
169 meters BLM Location Quantity Quads 37 Co
llimator 2 Cavities 2 Dump
2 BIG 1 Moveable 8 FBLM Location
Quantity Upstream 1 Bend 1 Dump 1
5Ring Loss Monitors
248 meter circumference BLM Location
Quantity Quad 44 Injection
7 Collimators 7 RF 5 Extraction
5 Moveable 7 FBLM Location
Quantity Injection 2 Straight Sec.
End 4 Bends 4 Extraction 2
6RTBT Loss Monitors
150 meters BLM Location Quantity Quads
27 Collimators 4 Dump
2 Target 3 Moveable 4 FBLM
Location Quantity Extraction 1 Collimators 1
Target area 1
7Liquid Cell/Photo-Multiplier Loss Monitor
-
- Detector
- Available commercially from Bicron, Model MAB.
- BC-505 Liquid (1,2,4 Trimethybenzene)
- More Rad hard than plastics, (about 10Xs)
- Highest light output of any liquid (80
anthracene) - Excellent light transmission (2.5m, min 1/e
attenuation) - High Flash point (48oC, 118oF)
- PMT - Hamamatsu 2060, 10 stage.
- Sensitivity on order of 100uC/R, Relative to
itself.
8Loss Signals
- Fast Loss Monitor Applications
- Fast instabilities
- Kicker errors
- Momentum errors
- Beam in Gap
- Ring wire scanner data
- Two Modes
- Integrated signal over bunch duration, read out
via digitizer clocked revolution frequency. - Losses within bunch. Signals buffered and sent
through wideband mux to fast digitizer (1 GS/s).
9FBLM - Liquid Cell Photo Multiplier
10Data Acquisition Control
- Buffer Electronics
- Wideband amp, drives two outputs.
- Loss Data
- All channels digitized through standard 60 MS/s
14 bit ADC. - Selected channels at 1 GS/s via mux, (Example
LeCroy 374 Scope) - Data transferred to high level via Channel
Access. - Multiplexer for 1 GS/s
- Keithley
- 7001 High Density Switch system
- 7016A 50 Ohm, Dual 1X4, 2 GHz Mux cards
- LED Test Pulse
- Remote control
- Timing
- HV Bias Control
- EPICs Driver to ISEG VME based Bias Supply
11HV Bias
- ISEG HV Bias Supply
- VME High Voltage Power Supplies in 2 slot width
- 1 channel and 2 channel versions in same
dimensions - LCD display for voltage or current
- variable rate of change of output voltage
- switched polarity
- integrated protection and control circuits
- output overload and short circuit protected
- SHV connector on front side
- Full control via VMEbus
- EPICs drivers
- 1.2k/channel
- Model VHQ 202M, 0-2kV, 3mA