Patent Pending
Daily Thermetrics
The new CatTracker Catalyst Tracking System is a
revolutionary method for providing a temperature
profile in fixed reactor beds. This unique
design possesses the following features.
This design measures more points in a Catalyst
bed This design has very quick response This
design utilizes our patented double seal This
design eliminates trouble spots that our
competitors designs have
2
Patent Pending
The CatTracker is a patented system for
monitoring temperature throughout catalyst beds
with a tube that senses points along its route.
3
Patent Pending
The Heart of the System is this special cable
4

Daily Thermocontrol
The CatTracker technology was developed with
Daily Thermetrics 34 years of experience in
manufacturing multipoints for the Chemical and
Refining industries with Daily Thermocontrols
experience in manufacturing thermocouples for the
demanding exhaust temperature applications of
fighter jet aircraft.
5
Patent Pending
The CatTracker design can get up to nine points
through a 1 nozzle. This gives you the ability
to get more points through a small nozzle than
with our competitor
6
Patent Pending
The CatTracker design can easily handle the
sensing needs of a whole reactor through one
nozzle on the top. A 6 2500 pound flange can
support 15 tubes, or 135 sensing points.
7
Patent Pending
The CatTracker design allows total tracking of a
complete bed through one nozzle
8
Produce
Load Catalyst
TC Install
The CatTracker is very easy and quick to install.
The TC installation is a critical path in a
turnarounds timeline.
9
Patent Pending
Daily Thermetrics manufactures the Cat Tracker s
multipoint tubes using a rotary swaging
process, while others use drawn thermocouples.
  • This gives us a compaction ratio of around 95
    versus the 75 of a drawn thermocouple
  • The higher the compaction ratio
  • The less the chance of the Thermocouple
    pinching on a bend
  • The lower the moisture content
  • The more protected the thermocouple is from
    outside contaminants that might leak in

10
Patent 4,848,927
  • The CatTrackers secondary containment, or Double
    Seal, has the following advantages
  • The reactor pressure and contents are designed to
    stay in the reactor, not in a chamber outside of
    the reactor walls
  • The Double Seal is shorter
  • The Double Seal has fewer weld points to go out
  • The Double Seal weighs less, making installation
    easier
  • The CatTracker is installed without tools, and
    all bends can be made by hand

11
Patent Pending
For more information on the CatTracker, please
contact us at the following
Daily Thermetrics
5700 Hartsdale
Dr.
Houston, TX 77036
1-800-783-2459
www.dailyinst.com