When it comes to designing a green data center, much can be done to promote energy efficiency and savings. Advanced technologies can help optimize roofs, walls, floors, layouts, cooling, lighting, server configuration and building management. Find out more from this presentation given by CEO of DP Air Corp, Arnie W. Evdokimo. – PowerPoint PPT presentation

Number of Views:352
Slides: 11
Provided by: dpair
Category:

less

Transcript and Presenter's Notes

Title: Green Data Center - DP Air


1
Green Data Center Using Measurement Tools to
Calculate Efficiency
2
Green Data Center
  • When it comes to designing a green data center,
    much can be done to promote energy efficiency and
    savings. Advanced technologies can help optimize
    roofs, walls, floors, layouts, cooling, lighting,
    server configuration and building management. The
    critical component of green initiatives is to
    properly plan the data center facility before
    equipment is installed.

3
Green Data Center
  • Green data center design efforts begin with the
    physical structure. Every detail of building
    construction is analyzed for efficiency. If not
    done during the design phase of a project,
    increasing efficiency becomes more costly,
    time-consuming and labor-intensive. And, the
    efficiencies gained after the fact may be
    limited.

4
Green Data Center
  • Incorporating green data center design from the
    start of a building project ensures the best
    levels of efficiencies and cost savings. Plus,
    businesses are better positioned to qualify for
    utility rebates, tax credits and other energy
    efficiency incentives.

5
Green Data Center
  • Knowing How to Measure a Green Data Center
  • Data centers are well known culprits for
    consuming vast amounts of energy. Not only
    costly, this energy consumption hinders good
    corporate citizenship. Therefore, todays data
    center managers are measuring efficiency so they
    have a guide for improvements.
  • One industry measurement tool is the Power Usage
    Efficiency (PUE) metric. This measurement will
    tell a data center operator where they stand in
    terms of energy efficiency. The company can then
    develop strategies to lower its PUE rating.

6
Green Data Center
  • PUE ratings are a good start for becoming a green
    data center and provide a baseline measurement.
    Industry sources publish ratings from which data
    center operators can compare their facilities.
  • The benefit of using a PUE rating for green data
    center goals is the consistent method of
    measuring energy consumption it provides. As the
    data center evolves with new technologies and
    equipment, the PUE rating can highlight the
    effects on energy efficiency.
  • The calculation involves a ratio of power
    available to power being used. The result of
    this calculation will be a factor greater than
    one. Therefore, the higher the calculated ratio,
    the less efficient energy consumption is in the
    data center.

7
Green Data Center
  • Another measurement tool is the Data Center
    Infrastructure Efficiency (DCiE). As the inverse
    of PUE, DCiE is the ratio of energy used in the
    data center compared to the total power
    available. The result will be less than one,
    with the best efficiency ratings being the
    closest to one. To help a companys green data
    center initiatives, online tools exist to help
    calculate these measurements.

8
Green Data Center
  • The Importance of PUE and DCiE Measurements
  • In addition to providing a baseline measurement
    for data center efficiency, PUE and DCiE
    calculations can provide crucial decision-making
    information. When companies commit to operating
    a green data center, they can decide if it makes
    better sense to build a new facility or enhance
    an existing one.

9
Green Data Center
  • These measurements also help with goal setting.
    For example, once a PUE rating is established,
    the company can set a goal to lower it to a
    certain number. To achieve this goal, the
    company develops strategies to improve energy
    consumption levels.
  • Power and cooling are prime targets for energy
    efficiency increases. The data center managers
    can develop strategies to reduce power
    consumption and improve cooling system operation.
    Some of these efforts can be straight-forward
    and make good economical sense. Other times, the
    existing data center might be at the end of its
    lifecycle and need replacement.

10
About the Author
  • Arnie W. Evdokimo is Chief Executive Officer of
    DP Air Corporation, a leading provider of data
    center design, build and maintenance services
    based in Phoenix, Arizona.
  • For more information about green data centers,
    visit http//www.DPAir.com today.