About This Presentation
Title:

CS5226 Hardware Tuning

Description:

... drives is often referred to as RAID 0. Only RAID 0, 1, 3 and 5 are commonly ... RAID 2 and 4 do not offer any significant advantages over these other types ... – PowerPoint PPT presentation

Number of Views:39
Avg rating:3.0/5.0
Slides: 37
Provided by: compN
Category:
Tags: cs5226 | hardware | raid | tuning

less

Transcript and Presenter's Notes

Title: CS5226 Hardware Tuning


1
CS5226 Hardware Tuning
2
ApplicationProgrammer(e.g., business
analyst, Data architect)
Application
SophisticatedApplicationProgrammer(e.g., SAP
admin)
Query Processor
Indexes
Storage Subsystem
Concurrency Control
Recovery
DBA,Tuner
Operating System
HardwareProcessor(s), Disk(s), Memory
3
Outline
  • Part 1 Tuning the storage subsystem
  • RAID storage system
  • Choosing a proper RAID level
  • Part 2 Enhancing the hardware configuration

4
Magnetic Disks
  • 1956 IBM (RAMAC) first disk drive
  • 5 Mb 0.002 Mb/in235000/year9 Kb/sec
  • 1980 SEAGATE
  • first 5.25 disk drive
  • 5 Mb 1.96 Mb/in2625 Kb/sec
  • 1999 IBM MICRODRIVE
  • first 1 disk drive340Mb 6.1 MB/sec

5
Magnetic Disks
  • Access Time (2001)
  • Controller overhead (0.2 ms)
  • Seek Time (4 to 9 ms)
  • Rotational Delay (2 to 6 ms)
  • Read/Write Time (10 to 500 KB/ms)
  • Disk Interface
  • IDE (16 bits, Ultra DMA - 25 MHz)
  • SCSI width (narrow 8 bits vs. wide 16 bits) -
    frequency (Ultra3 - 80 MHz).
  • http//www.pcguide.com/ref/hdd/

6
Storage Metrics
7
Hardware Bandwidth
System Bandwidth Yesterday in megabytes per
second (not to scale!)
Slide courtesy of J. Gray/L.Chung
Hard Disk SCSI PCI Memory Processor
8
Hardware Bandwidth
System Bandwidth Today in megabytes per second
(not to scale!)
Slide courtesy of J. Gray/L.Chung
Hard Disk SCSI PCI Memory Processor
9
RAID Storage System
  • Redundant Array of Inexpensive Disks
  • Combine multiple small, inexpensive disk drives
    into a group to yield performance exceeding that
    of one large, more expensive drive
  • Appear to the computer as a single virtual drive
  • Support fault-tolerance by redundantly storing
    information in various ways

10
RAID Types
  • Five types of array architectures, RAID 1 5
  • Different disk fault-tolerance
  • Different trade-offs in features and performance
  • A non-redundant array of disk drives is often
    referred to as RAID 0
  • Only RAID 0, 1, 3 and 5 are commonly used
  • RAID 2 and 4 do not offer any significant
    advantages over these other types
  • Certain combination is possible (10, 35 etc)
  • RAID 10 RAID 1 RAID 0

11
RAID 0 - Striping
  • No redundancy
  • No fault tolerance
  • High I/O performance
  • Parallel I/O

12
RAID 1 Mirroring
  • Provide good fault tolerance
  • Works ok if one disk in a pair is down
  • One write a physical write on each disk
  • One read either read both or read the less busy
    one
  • Could double the read rate

13
RAID 3 - Parallel Array with Parity
  • Fast read/write
  • All disk arms are synchronized
  • Speed is limited by the slowest disk

14
Parity Check - Classical
  • An extra bit added to a byte to detect errors in
    storage or transmission
  • Even (odd) parity means that the parity bit is
    set so that there are an even (odd) number of one
    bits in the word, including the parity bit
  • A single parity bit can only detect single bit
    errors since if an even number of bits are wrong
    then the parity bit will not change
  • It is not possible to tell which bit is wrong

15
RAID 5 Parity Checking
  • For error detection, rather than full redundancy
  • Each stripe unit has an extra parity stripe
  • Parity stripes are distributed

16
RAID 5 Read/Write
  • Read parallel stripes read from multiple disks
  • Good performance
  • Write 2 reads 2 writes
  • Read old data stripe read parity stripe (2
    reads)
  • XOR old data stripe with new data stripe.
  • XOR result into parity stripe.
  • Write new data stripe and new parity stripe (2
    writes).

17
RAID 10 Striped Mirroring
  • RAID 10 Striping mirroring
  • A striped array of RAID 1 arrays
  • High performance of RAID 0, and high tolerance of
    RAID 1 (at the cots of doubling disks)

.. More information about RAID disks at
http//www.acnc.com/04_01_05.html
18
Hardware vs. Software RAID
  • Software RAID
  • Software RAID run on the servers CPU
  • Directly dependent on server CPU performance and
    load
  • Occupies host system memory and CPU operation,
    degrading server performance
  • Hardware RAID
  • Hardware RAID run on the RAID controllers CPU
  • Does not occupy any host system memory. Is not
    operating system dependent
  • Host CPU can execute applications while the array
    adapter's processor simultaneously executes array
    functions true hardware multi-tasking

19
RAID Levels - Data
  • Settings
  • accounts( number, branchnum, balance)
  • create clustered index c on accounts(number)
  • 100000 rows
  • Cold Buffer
  • Dual Xeon (550MHz,512Kb), 1Gb RAM, Internal RAID
    controller from Adaptec (80Mb), 4x18Gb drives
    (10000RPM), Windows 2000.

20
RAID Levels - Transactions
  • No Concurrent Transactions
  • Read Intensive
  • select avg(balance) from accounts
  • Write Intensive, e.g. typical insert
  • insert into accounts values (690466,6840,2272.76)
  • Writes are uniformly distributed.

21
RAID Levels
  • SQL Server7 on Windows 2000 (SoftRAID means
    striping/parity at host)
  • Read-Intensive
  • Using multiple disks (RAID0, RAID 10, RAID5)
    increases throughput significantly.
  • Write-Intensive
  • Without cache, RAID 5 suffers. With cache, it is
    ok.

22
Comparing RAID Levels
23
Controller Pre-fetching No, Write-back Yes
  • Read-ahead
  • Prefetching at the disk controller level.
  • No information on access pattern.
  • Better to let database management system do it.
  • Write-back vs. write through
  • Write back transfer terminated as soon as data
    is written to cache.
  • Batteries to guarantee write back in case of
    power failure
  • Write through transfer terminated as soon as
    data is written to disk.

24
SCSI Controller Cache - Data
  • Settings
  • employees(ssnum, name, lat, long, hundreds1,
  • hundreds2)
  • create clustered index c on employees(hundreds2)
  • Employees table partitioned over two disks Log
    on a separate disk same controller (same
    channel).
  • 200 000 rows per table
  • Database buffer size limited to 400 Mb.
  • Dual Xeon (550MHz,512Kb), 1Gb RAM, Internal RAID
    controller from Adaptec (80Mb), 4x18Gb drives
    (10000RPM), Windows 2000.

25
SCSI (not disk) Controller Cache - Transactions
  • No Concurrent Transactions
  • update employees set lat long, long lat where
    hundreds2 ?
  • cache friendly update of 20,000 rows (90Mb)
  • cache unfriendly update of 200,000 rows (900Mb)

26
SCSI Controller Cache
  • SQL Server 7 on Windows 2000.
  • Adaptec ServerRaid controller
  • 80 Mb RAM
  • Write-back mode
  • Updates
  • Controller cache increases throughput whether
    operation is cache friendly or not.
  • Efficient replacement policy!

27
Which RAID Level to Use?
  • Data and Index Files
  • RAID 5 is best suited for read intensive apps or
    if the RAID controller cache is effective enough.
  • RAID 10 is best suited for write intensive apps.
  • Log File
  • RAID 1 is appropriate
  • Fault tolerance with high write throughput.
    Writes are synchronous and sequential. No
    benefits in striping.
  • Temporary Files
  • RAID 0 is appropriate.
  • No fault tolerance. High throughput.

28
What RAID Provides
  • Fault tolerance
  • It does not prevent disk drive failures
  • It enables real-time data recovery
  • High I/O performance
  • Mass data capacity
  • Configuration flexibility
  • Lower protected storage costs
  • Easy maintenance

29
Enhancing Hardware Config.
  • Add memory
  • Cheapest option to get better performance
  • Can be used to enlarge DB buffer pool
  • Better hit ratio
  • If used for enlarge OS buffer (as disk cache), it
    benefits but to other apps as well
  • Add disks
  • Add processors

30
Add Disks
  • Larger disk ?better performance
  • Bottleneck is disk bandwidth
  • Add disks for
  • A dedicated disk for the log
  • Switch RAID5 to RAID10 for update-intensive apps
  • Move secondary indexes to another disk for
    write-intensive apps
  • Partition read-intensive tables across many disks
  • Consider intelligent disk systems
  • Automatic replication and load balancing

31
Add Processors
  • Function parallelism
  • Use different processors for different tasks
  • GUI, Query Optimisation, TTCC, different types
    of apps, different users
  • Operation pipelines
  • E.g., scan, sort, select, join
  • Easy for RO apps, hard for update apps
  • Data partition parallelism
  • Partition data, thus the operation on the data

32
Parallelism
  • Some tasks are easier to parallelize
  • E.g., join phase of GRACE hash join
  • E.g., scan, join, sum, min
  • Some tasks are not so easy
  • E.g., sorting, avg, nested-queries

33
Summary
  • We have covered
  • The storage subsystem
  • RAID what are they and which one to use?
  • Memory, disks and processors
  • When to add what?

34
Database Tuning
  • Database Tuning is the activity of making a
    database application run more quickly. More
    quickly usually means higher throughput, though
    it may mean lower response time for time-critical
    applications.

35
Tuning Principles
  • Think globally, fix locally
  • Partitioning breaks bottlenecks (temporal and
    spatial)
  • Start-up costs are high running costs are low
  • Render onto server what is due onto Server
  • Be prepared for trade-offs (indexes and inserts)

36
Tuning Mindset
  • Set reasonable performance tuning goals
  • Measure and document current performance
  • Identify current system performance bottleneck
  • Identify current OS bottleneck
  • Tune the required components eg application, DB,
    I/O, contention, OS etc
  • Track and exercise change-control procedures
  • Measure and document current performance
  • Repeat step 3 through 7 until the goal is met

37
Goals Met?
  • Appreciation of DBMS architecture
  • Study the effect of various components on the
    performance of the systems
  • Tuning principle
  • Troubleshooting techniques for chasing down
    performance problems
  • Hands-on experience in Tuning
Write a Comment